EPA 608 Type 3 Questions | 2026/2027 | Answers Correct |
With Complete Solutions

______ is the process of removing refrigerant in any condition
from storing it in an external container without necessary testing
or processing it in any way Correct Answers Recovering

_______ refers to the process of cleaning refrigerant by oil
seperation 7 single or multiple passes through filter driers which
reduce moisture and acidity? Correct Answers Recycling

A compressor heater is used to: Correct Answers reduce the
amount of refrigerant in the lubricating oil

A cyclinder with a grey body and yellow top is designed to hold:
Correct Answers recovered refrigerant

A hydrostatic tube test kit is used to: Correct Answers
determine if a tube leaks

A passive system-dependent recovery device for small
appliances: Correct Answers captures refrigerant in a non-
pressurized container

A reciprocating compressor should not be energized if the
Correct Answers discharge service valve has closed

A recovery cyclinder which is 1/2 full of recovered R-410A @
90*F, in the absence of non-condensables will be presurized to:
Correct Answers 300 psig.

,A recovery cylinder which is 1/2 full of recovered R-22 at
normal room temperature about 75, in the absence of non-
condensables, will be pressurized to: Correct Answers 75 psig

A refrigerant that can be used as a direct service drop in
subsitute for R-12 in a small appliance is: Correct Answers
NONE

A rupture disc on a recovery vessel for a low pressure
refrigerants relieves at: Correct Answers 15 psig

A standard vacuum pump designed for evacuation &
dehydration can: Correct Answers be only used as a recovery
device in combination with a non pressurized container

A system can be evacuated to only atmospheric pressure when:
Correct Answers leaks in the appliance make the evacuation to
the prescribed level unattainable

A system does not have to be evacuated all the way to the
required level when: Correct Answers leaks in the appliance
make evacuation to the prescribed level unattainable

A system is considered dehydrated when: Correct Answers the
vacuum indicator shows you have reached & held the required
finished vacuum

A system is dehydrated to: Correct Answers remove water &
water vapor

, A system is dehydrated to: Correct Answers remove water and
water vapor

A ternary refrigerant blend is a ____ part mixture Correct
Answers 3

According to ASHRAE Guideline 3-1996, if the pressure in a
system rises from 1 mm Hg to a level above ____ during a
standing vacuum test, the system should be checked for leaks.
Correct Answers 2.5 mm Hg

According to ASHRAE's 1992 refrigerant safety classification,
which designations is the most safe Correct Answers A-1

According to the EPA there is approximately _____ refrigerant
vapor left in an average 350 ton R-11 chiller at 0 psig pressure
once all the R-11 liquid has been removed. Correct Answers
100 pounds

According to the EPA which recovery equipment maintenance
practice(s) should be preformed on a regular basis? Correct
Answers check recovery device for refrigerant leaks

After reaching the required recovery vacuum on a chiller, you
should Correct Answers Wait for at least a few minutes to see
if the system pressure rises, indicating that there is till
refrigerant in a liquid form or in the oil

After recovering the liquid refrigerant you must: Correct
Answers recover the vapor refrigerant

Document information

Uploaded on
October 7, 2026
Number of pages
18
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$15.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Classroom
4.0
(1208)
Sold
4995
Followers
3245
Items
56543
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions