• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 69 pages
Exam (elaborations)

New Hampshire Septic System Installer Exam Practice - Original Questions & Answers - Mound Systems & Alternative Designs - Detailed Rationales - Complete Exam

Document preview thumbnail
Preview 4 out of 69 pages

New Hampshire Septic System Installer Exam Practice - Original Questions & Answers - Mound Systems & Alternative Designs - Detailed Rationales - Complete Exam TABLE OF CONTENTS: Mound Systems When Separation Cannot Be Met 24 Inches in Fill 48 Inches to Ledge ASTM C33 Sand Observation Ports, Pressure Distribution Pump Chamber Manifold, Floodplain Requirements Watertight Tanks WELL-ASKED QUESTIONS (550Q): 1. What is required for a mound system in New Hampshire? A. No special requirements B. Required when separation to water table or ledge cannot be met with in-ground - 24 inches separation maintained in mound fill 48 inches to ledge observation ports specific sand fill ASTM C33 licensed installer C. Only sand D. No observation Answer: B Rationale: Mound required when separation cannot be met in-ground maintain 24 inches to water table in fill 48 inches to ledge ASTM C33 sand observation ports licensed installer. 2. What is the minimum setback from leach field to surface water (lake pond river) in NH? A. 10 feet B. 75 feet to surface water wetlands per Env-Wq 1008 75 feet to surface water 50 feet to very small C. 25 feet D. 100 feet Answer: B Rationale: NH setback leach field to surface water 75 feet to wetlands 75 feet. 3. How often must a septic tank be pumped in NH per DES recommendation? A. Every 10 years B. Every 3-5 years depending on use tank size garbage disposal inspection every 3-5 years pump when sludge+scum 1/3 tank depth C. Never D. Every year Answer: B Rationale: DES recommends pump every 3-5 years inspect pump when sludge+scum 1/3 depth. ... 547 more ... FEATURES: 550Q Mixed A=146 B=140 C=132 D=132 - Well-Asked - Mound Systems

Content preview

New Hampshire Septic System Installer Exam Practice - Original Questions & Answers - Mound Systems & Alternative
Designs - Detailed Rationales - Complete Exam
New Hampshire DES Subsurface Systems | Env-Wq 1000 | Septic System Installer License | Different Title 3


TABLE OF CONTENTS

1. I. NH DES Rules Env-Wq 1000 Overview - Subsurface Systems Bureau, Installer License Requirements Exam Experience CE
2. II. Soil Evaluation - Test Pit Requirements Depth 5 Feet Minimum, Seasonal High Water Table SHWT Redoximorphic Mottling Gray Colors
Observed Water March-June Monitor Wells
3. III. Separation Distances - 24 Inches Minimum Bottom of EDA to SHWT, 48 Inches to Ledge Refusal, Perc Test Depth Proposed System
Presoak
4. IV. Percolation Test - Soil Absorption Rate Minutes Per Inch, Test at Proposed Depth, Presoak, Sizing EDA Based on Rate
5. V. Design Flow - Bedrooms Flow 4 Bedroom 600 GPD, Septic Tank Sizing 4BR 1000 Gal 5BR 1250 Gal 6BR 1500 Gal, Garbage Disposal
Increase 20 Percent or 50 Percent Larger Tank
6. VI. Setbacks Env-Wq 1008 - Septic Tank 75 Feet Private Well Leach Field 75 Feet Private Well 100 Feet Public Well, Surface Water 75
Feet Wetlands 75 Feet, Property Line 10 Feet Building 10 Feet
7. VII. Effluent Disposal Area EDA - Trenches Beds Chambers, Trench Size 12 Inches Minimum Wide 18-36 Wide Depth 12-36 Aggregate 6
Below 2 Above Pipe, D-box Level 5 Ports Max Compacted Soil Accessible
8. VIII. Mound Systems - Required When Separation Cannot Be Met In-Ground, 24 Inches Separation Maintained in Fill, 48 Inches to Ledge,
ASTM C33 Sand Fill Observation Ports Licensed Installer
9. IX. Pressure Distribution - Required Mound Large Systems Perc greater than 30 mpi, Pump Chamber Pressure Manifold Small Holes Even
Distribution
10. X. Installation Standards - Pipe Slope 1/4 Inch Per Foot Tank to D-box 2 Percent Gravity Flow, Watertight Tanks, Floodplain Requirements
No Increase Flood Level
11. XI. Soil Types - Suitable Loamy Sand Sandy Loam, Unsuitable Clay Perc greater than 60 mpi High Water Table Ledge Within 24/48 Inches
Requires Alternative
12. XII. Pumping Maintenance - Every 3-5 Years Inspection Pump When Sludge plus Scum 1/3 Tank Depth
13. XIII. Replacement Systems - Must Meet Current Env-Wq 1000 Standards New Permit Test Pits Perc Required No Grandfather
14. XIV. Holding Tanks - Last Resort No Feasible EDA DES Waiver Frequent Pumping Alarm No New Construction Generally Hardship
15. XV. Practice Questions - Original Questions Each Asked Like Real NH Septic Installer Exam - Hinted Complete Exam
16. XVI. Answer Key with Detailed Rationales - Complete Exam

,NEW HAMPSHIRE SEPTIC SYSTEM INSTALLER EXAM - PRACTICE QUESTIONS - EACH QUESTION ASKED LIKE REAL

EXAM
Based on NH DES Env-Wq 1000 Subsurface Systems Rules, Setbacks, Test Pit, Perc Test, Design Flow, Mound Systems. High Yield.

1. How often must a septic tank be pumped in NH per DES recommendation?
A. Every 3-5 years depending on use, tank size, garbage disposal - inspection every 3-5 years, pump when sludge+scum 1/3 tank depth
B. Never
C. Every 10 years
D. Every year
Answer: A
Rationale: DES recommends pump every 3-5 years, inspect, pump when sludge+scum 1/3 depth.
2. What is the required setback distance from a septic tank to a private well in New Hampshire?
A. 25 feet
B. 75 feet minimum from septic tank to private well, 75 feet from leach field to private well per NH Env-Wq 1008 - 100 feet to public well
C. 50 feet
D. 10 feet
Answer: B
Rationale: NH setbacks: septic tank 75 feet to private well, leach field 75 feet to private well, 100 feet to public water supply well, 50 feet to surface
water? Actually 75 feet surface water? Check Env-Wq 1008 table.
3. What is the minimum size for a leach field trench in NH?
A. Typically 12 inches wide minimum, 18-36 inches wide trenches, depth 12-36 inches, aggregate 6 inches below 2 inches above pipe
B. 6 inches wide
C. 48 inches
D. No minimum
Answer: A
Rationale: Trench typically 12 inches minimum wide 18-36 wide depth 12-36 aggregate 6 below 2 above pipe per NH.
4. What is the purpose of a percolation test in NH septic design?
A. To find water table
B. To determine tank size
C. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
D. To find ledge
Answer: C
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
5. What is the purpose of a percolation test in NH septic design?
A. To find water table
B. To find ledge
C. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
D. To determine tank size
Answer: C
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
6. What is a holding tank and when allowed in NH?
A. Always for new homes
B. Allowed only as last resort no other feasible EDA, requires DES waiver, frequent pumping, alarm, no new construction generally - existing lots hardship
C. Always allowed
D. No restrictions
Answer: B
Rationale: Holding tank last resort no feasible EDA DES waiver frequent pumping alarm no new construction generally hardship.
7. What is the purpose of a percolation test in NH septic design?
A. To find water table
B. To determine tank size
C. To find ledge
D. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
Answer: D
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
8. What is the role of a D-box (distribution box) in NH septic?
A. Only stores
B. Distributes effluent evenly to laterals - must be level, 5 ports max, set on compacted soil, accessible
C. Only collects

,D. No role
Answer: B
Rationale: D-box distributes effluent evenly to laterals level 5 ports max compacted soil accessible.
9. What soil type is unsuitable for standard leach field in NH?
A. Sand
B. Clay with perc >60 min/inch - rate >60 mpi unsuitable - also high water table ledge within 24/48 inches - requires alternative system
C. Sandy loam
D. Loamy sand
Answer: B
Rationale: Clay perc >60 min/inch unsuitable for standard field requires alternative system.
10. What is an EDA in NH septic design?
A. Effluent Disposal Area - area where effluent disposed - includes leach field trenches beds, chamber systems - sizing based on perc rate and design
flow
B. No definition
C. Only pipe
D. Only tank
Answer: A
Rationale: EDA Effluent Disposal Area leach field trenches beds chambers sizing based on perc and flow.
11. What is the minimum setback from leach field to surface water (lake, pond, river) in NH?
A. 10 feet
B. 25 feet
C. 100 feet
D. 75 feet to surface water, wetlands - per Env-Wq 1008 - 75 feet to surface water, 50 feet to very small? Actually 75 feet standard
Answer: D
Rationale: NH setback leach field to surface water 75 feet, to wetlands 75 feet, check table Env-Wq 1008.
12. What is the purpose of a percolation test in NH septic design?
A. To find ledge
B. To find water table
C. To determine tank size
D. To determine soil absorption rate - minutes per inch - test at depth of proposed system, presoak, measure rate, determines sizing of leach field per
Env-Wq
Answer: D
Rationale: Perc test determines soil absorption rate minutes per inch at proposed depth, presoak required, sizing leach field based on rate.
13. What is the minimum size for a leach field trench in NH?
A. 48 inches
B. No minimum
C. 6 inches wide
D. Typically 12 inches wide minimum, 18-36 inches wide trenches, depth 12-36 inches, aggregate 6 inches below 2 inches above pipe
Answer: D
Rationale: Trench typically 12 inches minimum wide 18-36 wide depth 12-36 aggregate 6 below 2 above pipe per NH.
14. What is the role of a D-box (distribution box) in NH septic?
A. Only collects
B. Only stores
C. No role
D. Distributes effluent evenly to laterals - must be level, 5 ports max, set on compacted soil, accessible
Answer: D
Rationale: D-box distributes effluent evenly to laterals level 5 ports max compacted soil accessible.
15. What is an EDA in NH septic design?
A. Effluent Disposal Area - area where effluent disposed - includes leach field trenches beds, chamber systems - sizing based on perc rate and design
flow
B. No definition
C. Only pipe
D. Only tank
Answer: A
Rationale: EDA Effluent Disposal Area leach field trenches beds chambers sizing based on perc and flow.
16. What soil type is unsuitable for standard leach field in NH?
A. Sandy loam
B. Loamy sand
C. Sand
D. Clay with perc >60 min/inch - rate >60 mpi unsuitable - also high water table ledge within 24/48 inches - requires alternative system
Answer: D
Rationale: Clay perc >60 min/inch unsuitable for standard field requires alternative system.

, 17. How to determine seasonal high water table in NH test pit?
A. Only dig
B. No method
C. Observe soil redoximorphic features mottling, gray colors, observed water level during wet season March-June, monitor wells
D. Only guess
Answer: C
Rationale: SHWT determined by redoximorphic mottling gray colors observed water wet season March-June monitor wells.
18. What license is required to install septic in NH?
A. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
B. No exam
C. No license
D. Only plumbing license
Answer: A
Rationale: NH requires DES Septic System Installer license exam experience CE.
19. What is required for septic system in floodplain in NH?
A. Can install anywhere
B. Must meet additional DES requirements - floodplain construction, no increase flood level, watertight tanks, check local floodplain ordinance Env-Wq
C. No requirements
D. Only tank
Answer: B
Rationale: Floodplain septic must meet DES floodplain requirements watertight tanks no increase flood level local ordinance.
20. What license is required to install septic in NH?
A. NH DES Septic System Installer license - requires exam, experience, continuing education - Subsurface Systems
B. No license
C. Only plumbing license
D. No exam
Answer: A
Rationale: NH requires DES Septic System Installer license exam experience CE.
21. A 4-bedroom home in NH with 2.5 gpm well produces 600 gpd design flow. What size septic tank is required per NH rules?
A. 1000 gallons minimum for up to 4 bedrooms per Env-Wq - 4 bedrooms 1000 gal tank, 5 bedrooms 1250 gal, 6 bedrooms 1500 gal - 600 gpd 4BR
needs 1000 gal
B. 750 gallons
C. 500 gallons
D. 1500 gallons
Answer: A
Rationale: NH septic tank sizing: up to 4 bedrooms 1000 gal minimum, 5BR 1250 gal, 6BR 1500 gal per Env-Wq 1000.
22. A homeowner in New Hampshire wants to install a septic system on a lot with high seasonal high water table at 12 inches. What is the
minimum separation distance required between bottom of leach field and seasonal high water table per NH DES rules?
A. 24 inches minimum separation - bottom of bed must be 24 inches above seasonal high water table per Env-Wq 1000 - if 12 inches water table need fill
or mound
B. 6 inches
C. 12 inches
D. 0 inches
Answer: A
Rationale: NH Env-Wq 1000 requires 24 inches separation between bottom of leach field and seasonal high water table. If water table 12 inches need
mound system or fill.
23. What is an EDA in NH septic design?
A. Only pipe
B. No definition
C. Only tank
D. Effluent Disposal Area - area where effluent disposed - includes leach field trenches beds, chamber systems - sizing based on perc rate and design
flow
Answer: D
Rationale: EDA Effluent Disposal Area leach field trenches beds chambers sizing based on perc and flow.
24. What is the role of a D-box (distribution box) in NH septic?
A. Only stores
B. Only collects
C. Distributes effluent evenly to laterals - must be level, 5 ports max, set on compacted soil, accessible
D. No role
Answer: C
Rationale: D-box distributes effluent evenly to laterals level 5 ports max compacted soil accessible.
25. How often must a septic tank be pumped in NH per DES recommendation?

Document information

Uploaded on
October 6, 2026
Number of pages
69
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GradeAchiver
2.3
(4)
Sold
39
Followers
2
Items
3370
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions