,Which of the following statements about recycling and recovery equipment used for
stationary refrigeration is FALSE?
Purchases of such equipment must be reported to the EPA.
What should be done after reaching the required recovery vacuum on an appliance?
Wait for at least a few minutes to see if the system pressure rises.
What area of a refrigeration system does oil foaming usually occur?
Compressor
, When is it against EPA regulations to use system-dependant recovery equipment?
system-dependant recovery equipment? When the appliance contains over 15 pounds of
refrigerant.
What is the best use for testing with soap bubbles?
To pinpoint refrigeration leaks.
You are changing out the compressor of a system containing 40 pounds of R-404A. In
addition to isolating the compressor, which of the following procedures should you
follow?
Evacuate the isolated section of the system to 0 psig and if the system pressure does not
rise after a few minutes, remove the compressor.
How long must an HVAC service company keep records for each disposed appliance
with a charge between 5 and 50 pounds?
З years
When recovery is first started, at what phase is the refrigerant removed to save recovery
time?
Liquid phase