NATE GAS EXAM QUESTIONS AND ANSWERS
What is the typical load rating of the branch circuit over-
current protection for a residential gas furnace? - correct
answer 15 Amp
When selecting a replacement indoor blower motor,
which criteria should be included? - correct answer Motor
horsepower
What is the primary purpose of an off-delay timer in a gas
furnace? - correct answer Remove residual hear and prevent
nuisance limit trips
, NATE
To minimize noise problems in residential duct systems,
what is the range (recommended to maximum) of design
air velocity in the rectangular main supply trunk? - correct
answer 700 to 900 fpm
What is recommended for a pressurization leak test of
fuel gas pipe? - correct answer Compressed air
Induced draft blowers in direct vent condensing furnaces
pull combustion air from - correct answer outdoors only
Combustion air is often brought into a non-direct vent
gas furnace, located in an interior closet (confined space).
What consideration is important to remember? - correct
answer Two permanent openings of sufficient size must be
used
The height limitation for a vertical combustion air intake
on a condensing gas furnace is set by - correct answer the
furnace manufacturer