During a mold assessment of a multi-family building, you observe a distinct
musty odor in a unit with no visible mold growth and no reported water
intrusion. The HVAC system serves four units. Which action best aligns with
the principle that odor is a valid indicator of hidden microbial reservoirs?
A. Perform air sampling in the affected unit only and compare to an
outdoor control.
B. Recommend inspection of the shared HVAC plenum and condensate
drain pan for microbial amplification.
C. Issue a clearance report stating no mold is present based on the
absence of visible growth.
D. Advise the tenant to increase ventilation and re-evaluate in 30 days.
Correct Answer: B - Recommend inspection of the shared HVAC
plenum and condensate drain pan for microbial amplification.
RATIONALE
Musty odors often indicate volatile organic compounds (MVOCs)
from hidden mold growth, frequently in shared HVAC components.
Inspecting the shared plenum and drain pan addresses the likely
source. Air sampling alone may miss the reservoir, and clearance
without source identification is premature.
Question 2
A laboratory reports non-viable spore trap results from an indoor sample:
Penicillium/Aspergillus-like spores 12,000 spores/m³, Cladosporium 800
spores/m³, and Basidiospores 400 spores/m³. Outdoor control:
Penicillium/Aspergillus-like 1,200 spores/m³, Cladosporium 5,000 spores/m³,
Basidiospores 3,000 spores/m³. Which interpretation is most defensible?
A. The indoor environment is normal because total indoor spores are
within typical ranges.
B. The indoor sample indicates a hidden amplification site due to the
Page 2
, inverted Penicillium/Aspergillus ratio compared to outdoors.
C. The results are invalid because non-viable sampling cannot distinguish
species.
D. The elevated Cladosporium outdoors suggests the indoor sample was
contaminated.
Correct Answer: B - The indoor sample indicates a hidden
amplification site due to the inverted Penicillium/Aspergillus ratio
compared to outdoors.
RATIONALE
A significant increase in Penicillium/Aspergillus-like spores indoors
relative to outdoors, especially when this group is not dominant
outdoors, strongly suggests an indoor amplification site. The inversion
of ratios is a key indicator. Total spore counts alone can be misleading.
Question 3
Which condition would most likely require the use of a full-face powered
air-purifying respirator (PAPR) with P100 filters during mold remediation?
A. Remediation of 5 square feet of mold on drywall in an occupied office.
B. Remediation of 50 square feet of mold in a confined crawlspace with
limited ventilation.
C. Remediation of 100 square feet of mold in a well-ventilated
warehouse.
D. Remediation of 10 square feet of mold on a non-porous surface.
Correct Answer: B - Remediation of 50 square feet of mold in a
confined crawlspace with limited ventilation.
Page 3
, RATIONALE
Confined spaces with limited ventilation increase airborne
contaminant concentrations and may also present oxygen deficiency or
other hazards, warranting a higher level of respiratory protection such
as a PAPR with P100. Larger areas in well-ventilated spaces may
require less stringent protection depending on conditions.
Question 4
A mold assessment consultant is hired by a property owner to assess a
water-damaged building. The consultant also owns a remediation company.
Under Texas Mold Assessor rules, what is the most appropriate action?
A. Proceed with the assessment and offer remediation services to the
owner.
B. Disclose the ownership and obtain written consent from the owner
before proceeding.
C. Decline the assessment because a conflict of interest exists and cannot
be waived.
D. Perform the assessment but subcontract remediation to a third party.
Correct Answer: C - Decline the assessment because a conflict of
interest exists and cannot be waived.
RATIONALE
Texas Mold Assessor rules prohibit a mold assessment consultant
from also performing remediation on the same project due to a conflict
of interest. This prohibition is absolute and cannot be waived by
consent. The consultant must decline the assessment or divest the
remediation interest.
Question 5
In designing a remediation protocol for a school with widespread mold growth
in carpet and drywall, which sequence of containment and engineering controls
best minimizes cross-contamination?
Page 4