MASTER ELECTRICIAN LICENSE EXAM 2026/2027 WITH 180 QUESTIONS AND EXPERT VERIFIED CORRECT ANSWERS | ALREADY GRADED A+ | GUARANTEED PASS receptacles outlets installed for a appliance in a dwelling unit, such as a laundry equipment shall be located within of the intended location of the appliance - ANSWER-6ft there shall be a minimum of one branch circuit for laundry outlet - ANSWER-20 amp manhole openings for personnel shall be located where they are not directly above electrical equipment or conductors in the enclosure. where this is not practicable - ANSWER-a protective barrier or a fixed ladder shall be provided

Content preview

MASTER ELECTRICIAN LICENSE
EXAM 2026/2027 WITH 180
QUESTIONS AND EXPERT-
VERIFIED CORRECT ANSWERS |
ALREADY GRADED A+ |
GUARANTEED PASS




receptacles outlets installed for a appliance in a dwelling unit, such as a laundry
equipment shall be located within of the intended location of the appliance -
ANSWER-6ft


there shall be a minimum of one branch circuit for laundry outlet - ANSWER-20
amp


manhole openings for personnel shall be located where they are not directly above
electrical equipment or conductors in the enclosure. where this is not practicable -
ANSWER-a protective barrier or a fixed ladder shall be provided

,two or more small appliance branch circuits shall be provided to supply power for
receptacle outlets in the dwelling unit kitchen, dining room, breakfast room, or
similar dining areas - ANSWER-20 amp


the work space in front of electrical equipment shall not be less than wide . or the
width of the equipment which ever is greater - ANSWER-30"


in locations where electrical equipment is likely to be exposed to enclosures or
guards shall be so arranged and of such strength as to prevent such damage -
ANSWER-physical damage


What is the feeder or service calculated load for a waste disposal (940 VA),
dishwasher (1250VA), a trash compactor (1100VA), and a waste heater
(4500VA)? - ANSWER-5843 VA


GFCI protection at a carnival is not required for equipment at a circuit if the
receptacle is of the_______ type - ANSWER-locking


Where cables or nonmetallic raceways are installed through bored holes in joists,
rafters, or wood members, holes shall be board so that the edge of the hole is
________ the nearest edge of the wood member - ANSWER-not less than 1 1/4in
from


To guard live parts over 50V but less than 600V, equipment is permitted to be
______ - ANSWER-located in a room only accessible to qualified persons, located
on a balcony accessible only qualified persons, and elevated 8ft or more above
floor or other working surfaces

, How many receptacles are required within the perimeter of a balcony, deck, porch
with an unusable are of less than 20 SQ feet - ANSWER-1


Overhead feeder conductors shall have a minimum_________ vertical clearance
over residential property and driveways, as well as those commercial areas not
subject to truck traffic, where voltage is limited to 300 volts- to- ground -
ANSWER-12 feet


Where rear access is required to work on de-energized parts on the back of
enclosed equipment, a minimum working space of________ horizontally shall be
provided - ANSWER-36 inches


What is the maximum run length of an 18 AWG fixture wire that is tapped onto s
20 amp branch circuit? - ANSWER-50'


When the service disconnecting means power-operated switch or circuit breaker, it
shall be able to be opened by hand in the event of a _____ - ANSWER-power
supply failure


For equipment rated 1200 Amps or more and over 6ft wide that contains
overcurrent devices, switching devices, or control devices, there shall be one
entrance to and egress from the required working space not less than 24in. wide
and ______ high at each end of the working spaced - ANSWER-6ft 6 in


Conductors are considered outside buildings when they are buried under not less
than__________ - ANSWER-2 inches


In straight pull, the length of the box shall not be less than ________ times the
trade size of the largest raceway - ANSWER-8

Document information

Uploaded on
September 24, 2026
Number of pages
21
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$24.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
59
Followers
6
Items
1706
Last sold
5 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions