●● Overfill Protection notifies the operator when tank is at what level
capacity?
Answer: If equipped it will notify audibly and visually when the tank
reaches 90% Capacity.
●● Cathodic protection systems must be inspected by a certified
cathodic protection tester within______ months of installation
Answer: 6 months
●● Annual Monitor Certification records must be maintained on site for
a period of________ years
Answer: 3 years
●● The minimum monetary punishment for any person who falsifies
monitor records is?
Answer: $5,000
●● The quickest route for exposure to toxic substance is?
Answer: Inhalation
,●● For temporary tank closure you still need to monitor the tank but you
don't need an engineering report. Is this a true statement?
Answer: Yes
●● Asphyxiation is most likely to occur in low lying areas where
heavier-than-air-air-vapors accumulate. Asphyxiation can be caused by:
Answer: An Oxygen depleted environment
●● Where are ATG probes installed?
Answer: Through an opening in the top of the tank.
●● What is the minimum fine for disabling a monitoring system?
Answer: $5,000
●● (T/F) when performing secondary containment testing the spill
buckets get tested as well.
Answer: False: Spill buckets get tested during the annual monitor
certification.
●● Who must the annual monitor certification test results be sent to and
when must they be notified prior to testing and after testing?
Answer: Local agency must be notified prior 48 hours prior and results
must be submitted within 30 days of testing
, ●● (T/F) Stage II vapor recovery is a system for exchanging gasoline
vapors in a vehicle fuel tank and product in a storage tank so that vapor
omissions to the environment during refueling are greatly reduced.
Answer: True: because Stage I vapor recovery is from fuel delivery truck
to storage tank
●● __________must report an un-authorized release within _________
hours to the local agency
Answer: The owner or operator
24 hours
●● If automatic line leak detectors fail testing, what must happen?
Answer: They must be replaced and be able to detect a release of 3
gallons per hour at 10 pounds per square inch.
●● (T/F): The area inside the tank covered by fuel is considered the
"Ullage"
Answer: False: The area inside the tank not covered by fuel is
considered the "Ullage"
●● If equipped with an ATG it shall be programmed to test the
tank________
Answer: At least monthly
VERIFIED QUESTIONS AND ANSWERS
●● Overfill Protection notifies the operator when tank is at what level
capacity?
Answer: If equipped it will notify audibly and visually when the tank
reaches 90% Capacity.
●● Cathodic protection systems must be inspected by a certified
cathodic protection tester within______ months of installation
Answer: 6 months
●● Annual Monitor Certification records must be maintained on site for
a period of________ years
Answer: 3 years
●● The minimum monetary punishment for any person who falsifies
monitor records is?
Answer: $5,000
●● The quickest route for exposure to toxic substance is?
Answer: Inhalation
,●● For temporary tank closure you still need to monitor the tank but you
don't need an engineering report. Is this a true statement?
Answer: Yes
●● Asphyxiation is most likely to occur in low lying areas where
heavier-than-air-air-vapors accumulate. Asphyxiation can be caused by:
Answer: An Oxygen depleted environment
●● Where are ATG probes installed?
Answer: Through an opening in the top of the tank.
●● What is the minimum fine for disabling a monitoring system?
Answer: $5,000
●● (T/F) when performing secondary containment testing the spill
buckets get tested as well.
Answer: False: Spill buckets get tested during the annual monitor
certification.
●● Who must the annual monitor certification test results be sent to and
when must they be notified prior to testing and after testing?
Answer: Local agency must be notified prior 48 hours prior and results
must be submitted within 30 days of testing
, ●● (T/F) Stage II vapor recovery is a system for exchanging gasoline
vapors in a vehicle fuel tank and product in a storage tank so that vapor
omissions to the environment during refueling are greatly reduced.
Answer: True: because Stage I vapor recovery is from fuel delivery truck
to storage tank
●● __________must report an un-authorized release within _________
hours to the local agency
Answer: The owner or operator
24 hours
●● If automatic line leak detectors fail testing, what must happen?
Answer: They must be replaced and be able to detect a release of 3
gallons per hour at 10 pounds per square inch.
●● (T/F): The area inside the tank covered by fuel is considered the
"Ullage"
Answer: False: The area inside the tank not covered by fuel is
considered the "Ullage"
●● If equipped with an ATG it shall be programmed to test the
tank________
Answer: At least monthly