Crack the Nevada C-21B Air Conditioning Contractor trade exam on your first attempt with this essential 2-version practice set, updated for 2026 standards. Designed to mirror the PSI Licensure testing format, these exams cover the technical and safety knowledge required by the Nevada State Contractors Board (NSCB). What’s Inside the 2 Versions: Version A (Technical Fundamentals): Focuses on refrigeration cycles, load calculations (Manual N), HVAC duct construction (SMACNA), and equipment installation. Version B (Code & Safety): Deep dive into the 2018 Uniform Mechanical Code (UMC), EPA Section 608 regulations, and OSHA 1926 safety protocols. Detailed Answer Keys: Every question includes a rationale and reference to specific code sections to help you navigate your open-book materials faster. Key Topics Covered: Refrigerants, compressor troubleshooting, airflow dynamics, electrical controls, and Nevada-specific licensing regulations. Whether you are a journeyman looking to step up or an out-of-state contractor moving to Nevada, these practice tests are your best tool for mastering the timed 60-question PSI exam.

Content preview

Nevada (NV) C-21B Air Conditioning Contractor Practice
Exam 2026 | 2 Full Versions & Answer Keys

Question 1
According to the Uniform Mechanical Code (UMC), what is the minimum
clearance required in front of a furnace control side for service and
inspection?
A. 18 inches
B. 24 inches
C. 30 inches
D. 36 inches
Answer: C
Explanation: To ensure technician safety and proper tool
maneuverability, the UMC requires a minimum of 30 inches of
working space in front of the control side of the equipment. This
allows for the safe removal of burners, blowers, and controls
without obstruction.


Question 2
When installing a condensate drain line for a high-efficiency furnace, what
is the minimum slope required to ensure proper drainage?

,A. 1/8 inch per foot
B. 1/4 inch per foot
C. 1/2 inch per foot
D. 1 inch per foot
Answer: B
Explanation: Gravity-fed condensate lines must maintain a minimum
slope of 1/4 inch per foot (2% grade). If the slope is too shallow,
biofilm (slime) can build up, leading to clogs, water damage, and
system shutdown via the float switch.


Question 3
In a heat pump system, the "Reversing Valve" is typically energized in
which mode for most manufacturers?
A. Heating
B. Cooling
C. Defrost only
D. Emergency heat only
Answer: B
Explanation: While some brands vary (like Rheem/Ruud), the
industry standard (Carrier, Trane, Goodman) is for the reversing
valve (O-terminal) to be energized in the cooling mode. This allows
the system to fail-safe into the heating mode during winter if the
solenoid coil fails.

,Question 4
What is the maximum permitted length of a flexible air duct (flex duct)
according to standard Nevada energy conservation codes?
A. 5 feet
B. 10 feet
C. 14 feet
D. 25 feet
Answer: C
Explanation: While some jurisdictions allow longer runs, the general
standard for efficiency is to limit flexible ducts to 14 feet.
Excessively long flex duct runs significantly increase static
pressure and reduce airflow due to the internal friction of the wire
helix.


Question 5
According to the International Fuel Gas Code (IFGC), a gas shut-off valve
must be located within how many feet of the appliance it serves?
A. 3 feet
B. 6 feet
C. 10 feet
D. Within the same room, no distance limit

, Answer: B
Explanation: The shut-off valve must be in the same room and within
6 feet of the appliance. This ensures that in the event of a gas leak
or fire at the unit, a technician or occupant can quickly and safely
isolate the fuel source.


Question 6
What is the primary purpose of a "Subcooling" measurement when
charging a system with a Thermostatic Expansion Valve (TXV)?
A. To check the evaporator's efficiency.
B. To ensure the condenser is clean.
C. To verify the liquid line has a solid column of refrigerant.
D. To check for non-condensables.
Answer: C
Explanation: Subcooling is the temperature drop of the liquid
refrigerant below its saturation point. For TXV systems, subcooling
is the preferred charging method because the TXV maintains a
constant superheat. High subcooling ensures no vapor bubbles
(flash gas) enter the TXV, which would reduce its capacity.

Document information

Uploaded on
September 17, 2026
Number of pages
139
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$47.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
2
Followers
0
Items
78
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions