NORTH CAROLINA RESIDENTIAL
SINGLE-FAMILY DWELLING
ELECTRICAL CONTRACTOR
LICENSING (SP-SFD) 2026/2027 FINAL
PREP QUESTIONS AND CORRECT
ANSWERS WITH EXPLANATIONS


1. According to NEC 210.8(A), which of the following residential locations does NOT strictly

require GFCI protection for 125-volt, single-phase, 15- and 20-ampere receptacles?

A. Finished basement areas not intended as habitable rooms


B. Sinks in areas other than kitchens where receptacles are within 6 feet of the top inside

edge


C. Indoor damp or wet locations


D. Attics containing HVAC equipment


Answer: D


Conceptual Explanation: NEC 210.8(A) lists specific areas requiring GFCI. While

basements (finished or unfinished), sinks, and damp locations are included, attics are

generally not included unless they contain specific equipment like a crawl space pump or if

they meet other specific criteria; however, 210.8(E) now requires GFCI for crawl space

lighting, but standard attic receptacles for general use are not listed in 210.8(A).

,2. When calculating the service load for a single-family dwelling using the standard method,

what is the demand factor for the first 3,000 volt-amperes of the general lighting load?

A. 100%


B. 45%


C. 35%


D. 75%


Answer: A


Conceptual Explanation: Per Table 220.42, the first 3,000 VA of the lighting load is

calculated at 100%, the next 3,001 to 120,000 VA at 35%, and anything over 120,000 VA at

25%.


3. In a residential dwelling, what is the minimum number of 20-ampere small-appliance

branch circuits required for the kitchen and dining areas?

A. Two


B. One


C. Three


D. Four


Answer: A


Conceptual Explanation: NEC 210.11(C)(1) requires at least two 20-ampere small-

appliance branch circuits to serve all receptacle outlets covered by 210.52(B).

, 4. A 120/240-volt, 3-wire service for a single-family dwelling has a total calculated load of 185

amperes. According to NEC 310.12, what is the minimum size Copper conductor required for

the service-entrance?

A. 1/0 AWG


B. 2/0 AWG


C. 4/0 AWG


D. 3/0 AWG


Answer: D


Conceptual Explanation: NEC Table 310.12 allows a 200A residential service to use 2/0

AWG Cu, but for 185A calculated load, we typically use the next standard size. Table 310.12

specifically allows 3/0 AWG Cu for 225A and 2/0 for 200A. Since 185A is below 200A, 2/0

would technically suffice for a 200A rated service, but if the main is rated 200A, 2/0 Cu is

the residential standard.


5. What is the maximum distance a receptacle can be located from the edge of a kitchen

basin before it no longer counts as a ‘countertop’ receptacle?

A. 12 inches


B. 18 inches


C. 48 inches


D. 24 inches

Document information

Uploaded on
September 16, 2026
Number of pages
26
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar
3.7
(140)
Sold
717
Followers
178
Items
27641
Last sold
2 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions