1. What is the minimum number of risers on a stairway that requires a handrail
under NSPIRE?
A) Two risers
B) Three risers
C) Four risers
D) Five risers
Rationale: A stairway with four or more risers must have a handrail. This is a
fundamental stair safety requirement under NSPIRE.
2. What is the minimum height for a guardrail on a walking surface?
A) 24 inches
B) 30 inches
C) 36 inches
,D) 42 inches
Rationale: A guardrail must be at least 30 inches high. A guardrail is required whenever
there is a drop of 30 inches or more from a walking surface.
3. What size foundation crack is considered a deficiency?
A) 1/8 inch wide by 6 inches long
B) 1/4 inch wide by 12 inches long
C) 1/2 inch wide by 12 inches long
D) 1 inch wide by 12 inches long
Rationale: A foundation crack measuring 1/4 inch wide and 12 inches long is a
deficiency. Smaller or shorter cracks are not cited.
4. What size ceiling hole is considered a deficiency?
A) 1 inch
B) 2 inches
C) 3 inches
D) 4 inches
Rationale: Any ceiling hole 2 inches or larger is a deficiency. Even a smaller hole may be
cited if daylight is visible through it from the exterior.
5. What length of exposed electrical wiring is considered a deficiency?
A) 1/4 inch
,B) 1/2 inch
C) 1 inch
D) 2 inches
Rationale: Any exposed electrical wiring of 1/2 inch or more is a deficiency. Exposed
wiring presents shock and fire hazards.
6. What is the maximum allowable height of a call-for-aid pull cord from the floor?
A) 2 inches
B) 4 inches
C) 6 inches
D) 12 inches
Rationale: The pull cord must not exceed 6 inches from the floor to ensure accessibility
for residents who may have fallen or have limited mobility.
7. What clearance is required between combustible materials and a fuel-burning
water heater?
A) 1 foot
B) 2 feet
C) 3 feet
D) No clearance required
Rationale: Flammable or combustible items must not be stored on or within 3 feet of a
fuel-burning appliance or water heater. This requirement does not apply to electric water
heaters.
, 8. What is the minimum interior temperature required during the heating season
(October 1 through March 31)?
A) 55°F
B) 60°F
C) 64°F
D) 68°F
Rationale: If the permanently installed heating source is working but the interior
temperature is below 64°F during the inspection period from October 1 through March 31,
it is a deficiency.
9. What type of space heater is prohibited under NSPIRE?
A) Electric space heaters
B) Unvented space heaters that burn gas, oil, or kerosene
C) Ceramic space heaters
D) Oil-filled electric radiators
Rationale: Unvented space heaters that burn gas, oil, or kerosene are prohibited because
they release combustion byproducts into the living space, creating carbon monoxide
hazards.
10. How many means of fire egress must each living space have?
A) One
B) Two