CORE DOMAINS
1. Electrical Theory and Fundamentals
2. Sign Lighting Systems and Components
3. National Electrical Code (NEC) and TDLR Regulations
4. Sign Installation and Structural Considerations
5. Electrical Wiring Methods and Materials
6. Transformers, Power Supplies, and Load Calculations
7. Safety, OSHA Standards, and Hazard Prevention
8. Troubleshooting, Maintenance, and Repair
9. Ethics, Professional Standards, and Business Practices
10. Plan Reading, Estimating, and Permitting
INTRODUCTION
The TDLR Sign Electrician Exam is designed to assess the knowledge, skills, and competency of individuals
seeking licensure as sign electricians in the State of Texas. The examination evaluates a candidate's
understanding of electrical theory, sign lighting systems, regulatory compliance, safety procedures, and
professional standards. The exam utilizes a multiple-choice and scenario-based format to emphasize
real-world application, critical thinking, and sound professional decision-making. Candidates are
expected to demonstrate the ability to interpret code requirements, solve practical problems, and apply
ethical judgment in workplace situations. This assessment serves as a comprehensive tool to prepare
candidates for the responsibilities and challenges of the sign electrician trade.
SECTION ONE – QUESTIONS 1–100
Question 1
What is the primary purpose of a ballast in a fluorescent sign lighting system?
A. To increase the voltage to the lamp
B. To regulate the current flowing through the lamp
C. To convert AC power to DC power
D. To provide a ground path for the fixture
🟢 Correct answer: B. To regulate the current flowing through the lamp
🔴 Explanation: A ballast is designed to provide the necessary starting voltage and then regulate the
current to the fluorescent lamp to prevent it from drawing excessive current and burning out.
Question 2
A sign electrician is installing a new 120-volt branch circuit for a neon sign. According to the NEC, what
,is the minimum number of overload protection devices required for this circuit?
A. One
B. Two
C. Three
D. None
🟢 Correct answer: A. One
🔴 Explanation: Each ungrounded conductor in a branch circuit requires overcurrent protection. A
standard 120-volt circuit has one ungrounded conductor, requiring one overcurrent device.
Question 3
Which of the following is the most critical factor when selecting a disconnecting means for a sign?
A. The color of the disconnect switch
B. The voltage rating and current capacity
C. The brand of the disconnect switch
D. The physical size of the disconnect switch
🟢 Correct answer: B. The voltage rating and current capacity
🔴 Explanation: The disconnecting means must be rated for the voltage and current of the circuit it
controls to ensure safe operation and code compliance.
Question 4
A customer wants a sign installed on a building facade. The sign will be illuminated by LED modules.
What is the most important consideration for the power supply?
A. The color of the power supply casing
B. The power supply's output voltage and current rating
C. The weight of the power supply
D. The brand name of the power supply
🟢 Correct answer: B. The power supply's output voltage and current rating
🔴 Explanation: The power supply must match the voltage and current requirements of the LED
modules to ensure proper operation and longevity.
Question 5
What is the primary function of a ground fault circuit interrupter (GFCI) in a sign circuit?
A. To protect equipment from voltage surges
B. To protect personnel from electrical shock
C. To increase the brightness of the sign
D. To reduce energy consumption
🟢 Correct answer: B. To protect personnel from electrical shock
🔴 Explanation: A GFCI detects an imbalance in current flow and quickly disconnects power to prevent
electric shock hazards.
,Question 6
When installing a sign in a wet location, which of the following wiring methods is most appropriate?
A. Romex (NM-B) cable
B. Underground feeder (UF) cable
C. Armored cable (AC)
D. Non-metallic sheathed cable
🟢 Correct answer: B. Underground feeder (UF) cable
🔴 Explanation: UF cable is rated for direct burial and wet locations, making it suitable for outdoor
sign installations.
Question 7
A sign electrician is troubleshooting a neon sign that is not lighting. The transformer is humming but
no light is produced. What is the most likely cause?
A. The transformer is overloaded
B. The secondary wiring is open
C. The primary voltage is too high
D. The sign is grounded
🟢 Correct answer: B. The secondary wiring is open
🔴 Explanation: If the transformer hums but no light is produced, the secondary circuit is likely open,
preventing current from flowing through the neon tubing.
Question 8
According to the NEC, what is the maximum allowable voltage for a sign circuit in a residential
occupancy?
A. 120 volts
B. 240 volts
C. 277 volts
D. 480 volts
🟢 Correct answer: A. 120 volts
🔴 Explanation: Residential sign circuits are typically limited to 120 volts for safety and standard
compliance.
Question 9
What is the purpose of a time clock in a sign lighting circuit?
A. To measure the voltage of the circuit
B. To automatically turn the sign on and off at preset times
C. To increase the current to the sign
D. To provide a ground path
🟢 Correct answer: B. To automatically turn the sign on and off at preset times
🔴 Explanation: A time clock controls the operation of the sign based on a schedule, improving energy
efficiency and convenience.
, Question 10
A sign electrician is asked to install a new sign that requires a 20-ampere circuit. What is the minimum
wire size that should be used?
A. 14 AWG copper
B. 12 AWG copper
C. 10 AWG copper
D. 8 AWG copper
🟢 Correct answer: B. 12 AWG copper
🔴 Explanation: According to the NEC, 12 AWG copper wire is rated for 20 amperes, making it the
minimum size for this circuit.
Question 11
Which of the following is a key responsibility of a sign electrician regarding ethics?
A. Maximizing profit at all costs
B. Performing work only when supervised
C. Adhering to code and safety standards
D. Avoiding communication with clients
🟢 Correct answer: C. Adhering to code and safety standards
🔴 Explanation: Ethical practice requires sign electricians to follow all applicable codes and safety
standards to protect the public and the integrity of the trade.
Question 12
What is the primary hazard associated with working on a live electrical circuit?
A. Low voltage
B. Electric shock
C. Excessive lighting
D. Noise pollution
🟢 Correct answer: B. Electric shock
🔴 Explanation: The primary hazard of working on live circuits is electric shock, which can cause
serious injury or death.
Question 13
A sign electrician is installing a new LED sign. The manufacturer specifies a maximum run length of 20
feet for the LED modules. What should the electrician do if the sign is 30 feet long?
A. Connect the modules in a single run
B. Use a larger power supply
C. Split the sign into multiple runs with separate power supplies
D. Ignore the manufacturer's specification
🟢 Correct answer: C. Split the sign into multiple runs with separate power supplies
🔴 Explanation: Exceeding the maximum run length can cause voltage drop and uneven illumination.
Splitting the sign into multiple runs ensures proper operation.