SECTION 1: COMBUSTION AIR AND VENTILATION
(Questions 1-25)
Question 1
According to the IFGC, what is the fundamental requirement for most appliances before
they can be approved for installation?
A) They must be manufactured in the United States
B) They must be listed and labeled for the specific application in which they are
used
C) They must have a minimum efficiency rating set by the local utility
D) They must be installed by the manufacturer's authorized representative
Rationale: Codes require appliances to be listed and labeled for their specific application.
Listing and labeling are only valid for the application they were evaluated for. This ensures
the appliance has been tested and certified for the intended use .
,Question 2
When sizing combustion air openings that communicate directly with the outdoors,
what is the required ratio of free area to appliance input?
A) 1 square inch per 1,000 BTU/hr
B) 1 square inch per 4,000 BTU/hr
C) 1 square inch per 7,500 BTU/hr
D) 1 square inch per 10,000 BTU/hr
Rationale: For combustion air openings communicating directly with the outdoors, the
code specifies a minimum of 1 square inch of free area for every 4,000 BTU/hr of total
appliance input. The calculation uses net free area after accounting for louvers and
screens .
Question 3
A horizontal combustion air duct requires a larger opening than a vertical duct. What is
the required ratio for horizontal ducts?
A) 1 square inch per 4,000 BTU/hr
B) 1 square inch per 2,000 BTU/hr
C) 1 square inch per 6,000 BTU/hr
D) 1 square inch per 8,000 BTU/hr
Rationale: Horizontal ducts add more resistance to airflow. The code compensates by
requiring 1 square inch of free area per 2,000 BTU/hr for horizontal ducts, which is more
than the 1 per 4,000 ratio used for direct or vertical openings .
Question 4
What is the minimum outdoor air intake opening dimension allowed by code?
,A) 1 inch
B) 2 inches
C) 3 inches
D) 4 inches
Rationale: The minimum dimension for a combustion air opening is 3 inches, even if the
total square-inch area appears adequate. This prevents narrow slots or undersized duct
throats that could restrict airflow .
Question 5
An appliance installed in a confined space must be provided with:
A) One permanent opening for combustion air
B) Two permanent openings for combustion air
C) No additional openings if the space is large enough
D) Mechanical ventilation only
Rationale: An appliance installed in a confined space must be provided with two
permanent openings for combustion air—one high and one low—to ensure proper air
circulation .
Question 6
What is the minimum termination height for a vent pipe serving a gas water heater on a
residential roof?
A) 12 inches above the roof surface
B) 24 inches above the roof surface
C) 36 inches above the roof surface
D) 48 inches above the roof surface
Rationale: The code requires vent terminations to be at least 36 inches above the roof to
prevent re-entrainment of exhaust gases. This height ensures safe dispersion of
combustion byproducts .
, Question 7
A vent connector serving a natural gas boiler must be installed with what minimum
slope?
A) 1/8 inch per foot toward the vent
B) 1/4 inch per foot upward toward the vent or chimney
C) 1/2 inch per foot away from the vent
D) No slope is required for mechanical draft systems
Rationale: A vent connector must be installed without dips or sags and must slope
upward toward the vent or chimney at least 1/4 inch per foot. This ensures proper draft
and prevents condensation accumulation .
Question 8
What is the minimum clearance required between a single-wall metal vent pipe and
combustible material?
A) 1 inch
B) 3 inches
C) 6 inches
D) 9 inches
Rationale: Single-wall metal vent connectors require 6 inches of clearance from
combustible materials to prevent fire hazards from high surface temperatures .
Question 9
According to the 2024 IFGC, what does Section 304.12 address?
A) Sizing of gas piping
B) Protection from fumes and gases