Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

ICC RES ELEC INSPECTOR E1 ACTUAL EXAM QUESTIONS AND CORRECT ANSWERS LATEST UPDATE 2026/2027 GRADED A+ .

Document preview thumbnail
Preview 2 out of 7 pages

1. where an attic space is not provided with permeant stairs or a ladder, protection for feeder cables running across the face of the rafters in the attic shall only be required within of the nearest edge of the attic entrance ANSW 6 ftNEC 334.23& 320.23 (A) 2. Termination provisions of equipment for circuits marked for conductors shall be used for conductors rated at a minimum of 75 degrees Celsius ANSW # 1 AWG NEC 110.14 (C)(1)(b) 3. what size EGC for 70 AMP circuit ANSW #8AWGNEC250.122 4. A Feeder will be protected by fuses rated by 125 Amp. What size AL EGC is required to be run in a raceway with feedersupply conductors? ANSW #4AWGNEC250.122 5. What load shall be provided for each20 Amp circuit serving receptacles in a laundry area? ANSW 1500VA NEC 220.51(A) 6. Given ANSW Three appliances fastened in place are as follows ANSW Dishwasher rated at 1800VA, water heater at 6000 VA and room C at 1600VA. what is the mini-mum-calculated demand load for all appliances? ANSW NEC 220.53 = 1.8kVA+6kVa+1.6kVa=9.4Kva X 100% =9400 VAD 7. What is the maximum percent of unbalance load to be considered for a feeder neutral load regarding the ungrounded feeder conductors in the supply electric ranges, wall mounted ovens, counter top cooking units, and electric dryer? ANSW 70%NEC220.61(B)(1) 8. What is the maximum rating of any one cord and plug connected utilization equipment when not fastened in place and supplied by 15 amp branch cir-cuit? ANSW 80% NEC210.23(A)(1) 9. Outlets installed for the purpose of charging EV shall be supplied by branch circuit ANSW Individual NEC 625.40 10. Ranges shall b supplied by a minimum branch circuit of when the rating of rangesis 8.75kva or more ANSW 40AMPNEC210.19(A)(3) 11. What is the minimum amount of branch circuits required to serve recepta-cles outlets located in the laundry area of a dwelling ? ANSW 1-20AMP branch circuit NEC 210.11 (C)(2)

Content preview

ICC RES ELEC INSPECTOR E1
ACTUAL EXAM QUESTIONS
AND CORRECT ANSWERS
LATEST UPDATE 2026/2027
GRADED A+ .

, 1. where an attic space is not provided with permeant stairs or a ladder, protection for feeder cables running
across the face of the rafters in the attic shall only be required within of the nearest edge of the attic entrance ✔✔
ANSW 6 ft NEC
334.23& 320.23 (A)

2. Termination provisions of equipment for circuits marked for conductors

shall be used for conductors rated at a minimum of 75 degrees Celsius ✔✔ ANSW # 1
AWG NEC 110.14 (C)(1)(b)

3. what size EGC for 70 AMP circuit ✔✔ ANSW # 8 AWG NEC 250.122

4. A Feeder will be protected by fuses rated by 125 Amp. What size AL EGC is required to be run in a raceway with
feeder supply conductors? ✔✔ ANSW #4AWGNEC 250.122

5. What load shall be provided for each20 Amp circuit serving receptacles in a laundry area? ✔✔ ANSW 1500VA NEC
220.51(A)

6. Given ✔✔ ANSW Three appliances fastened in place are as follows ✔✔ ANSW Dishwasher rated at
1800VA, water heater at 6000 VA and room C at 1600VA. what is the mini-mum-calculated demand load for all
appliances? ✔✔ ANSW NEC 220.53 = 1.8kVA+6kVa+1.6kVa=9.4Kva X 100% =9400 VAD

7. What is the maximum percent of unbalance load to be considered for

a feeder neutral load regarding the ungrounded feeder conductors in the supply electric ranges, wall mounted
ovens, counter top cooking units, and electric dryer? ✔✔ ANSW 70% NEC 220.61(B)(1)

8. What is the maximum rating of any one cord and plug connected utilization equipment when not fastened in
place and supplied by 15 amp branch cir-cuit? ✔✔ ANSW 80 % NEC 210.23(A)(1)

9. Outlets installed for the purpose of charging EV shall be supplied by

branch circuit ✔✔ ANSW Individual NEC 625.40

10. Ranges shall b supplied by a minimum branch circuit of when the
rating of ranges is 8.75kva or more ✔✔ ANSW 40AMP NEC 210.19(A)(3)

11. What is the minimum amount of branch circuits required to serve recepta-cles outlets located in the laundry area of
a dwelling ? ✔✔ ANSW 1-20AMP branch circuit NEC 210.11 (C)(2)

Document information

Uploaded on
September 8, 2026
Number of pages
7
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
lectdenis
3.7
(301)
Sold
2089
Followers
1592
Items
6821
Last sold
18 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions