,Topics Covered
Section 1: Fire Department Connection
Questions covering fire Department Connection concepts.
Section 2: Control Valves
Questions covering control Valves concepts.
Section 3: Water Supply Systems
Questions covering water Supply Systems concepts.
Section 4: Sprinkler Systems
Questions covering sprinkler Systems concepts.
Section 5: Fire Pumps
Questions covering fire Pumps concepts.
Section 6: Sprinkler Types
Questions covering sprinkler Types concepts.
Section 7: Hydraulic Calculations
Questions covering hydraulic Calculations concepts.
Section 8: Impairment Coordination
Questions covering impairment Coordination concepts.
Section 9: Standpipe Maintenance and More
Questions covering standpipe Maintenance and More concepts.
Section 10: Testing Procedures
Questions covering testing Procedures concepts.
Section 11: Alarm Systems
Questions covering alarm Systems concepts.
Section 12: Hose Specifications
Questions covering hose Specifications concepts.
Section 13: Standpipe Systems
Questions covering standpipe Systems concepts.
Section 14: Standpipe Installation
Questions covering standpipe Installation concepts.
Section 15: Standpipe Testing
Questions covering standpipe Testing concepts.
S-12 Sprinkler Test & S-13 Standpipe Test Questions & Answers 2026-2027 | Sprinklers Segment 5 - Practice Questions Page 0
,Questions
QUESTION 1 OF 398
fire department connection
Correct Answer: normally on exterior of building... FDNY can pump supplemental water into the sprinkler
system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water
supplies.
QUESTION 2 OF 398
Fire pump, automatic standpipe.
Correct Answer: A fire pump located at or below street level that supplies the lower 300 feet (91.4 m) of a
standpipe system or a combined standpipe and sprinkler system.
QUESTION 3 OF 398
tags
Correct Answer: on closed section valves serving affected areas: area affected, brief description, occupancy
classification, c of f number, estimated time until operational
QUESTION 4 OF 398
Pumper Connections for Fire Department Use
Correct Answer: Fire Department connections must always be accessible. Each connection shall be fitted
with a lower check valve. The lower check valve prevents the backflow of the private water supply into the
Fire Department connection. The figure below shows the main features of a Fire Department connection.
QUESTION 5 OF 398
fire hydrant
Correct Answer: A valve connection on a water supply system having one or more outlets and that is used
to supply hose and fire department pumps with water.
QUESTION 6 OF 398
what is a fire hydrant?
Correct Answer: A valve connection on a water supply system having one or more outlets and that is used
to supply hose and fire department connections with water.
QUESTION 7 OF 398
What is the purpose of gate valves?
Correct Answer: A valve controlling flow to water based fire protection systems. Is used to isolate,shut off,
and open sprinkler systems.
S-12 Sprinkler Test & S-13 Standpipe Test Questions & Answers 2026-2027 | Sprinklers Segment 5 - Practice Questions Page 0
, QUESTION 8 OF 398
Auxiliary water supply
Correct Answer: supplementary source of water for a standpipe and/or sprinkler system.
QUESTION 9 OF 398
Fire Department Connection
Correct Answer: A connection , normally on the exterior of the building, through which the fire
department can pump supplemental water into the sprinkler system, standpipe, or other system furnishing
water for fire extinguishment to
supplement existing water supplies. (Formerly know as Siamese connection.)
QUESTION 10 OF 398
Hose Station
Correct Answer: a combination of a hose rack, hose nozzle, hose, and hose connection.
QUESTION 11 OF 398
Pressure Relief Valve
Correct Answer: A valve designed for the purpose of releasing excess air or water pressure from the Fire
Protection Piping System. Pressure relief valve is not a pressure reducing valve.
QUESTION 12 OF 398
Alarm check Valves
Correct Answer: An alarm check valve is basically a check valve with an alarm port. The main purpose of
the alarm check valve is to ring a mechanical bell called a water motor gong.
QUESTION 13 OF 398
The Diameters for fixed pipe diameters would be:
Correct Answer: 4-6 inches
QUESTION 14 OF 398
What are the two types of fire department connections?
Correct Answer: Freestanding & Wall mounted
QUESTION 15 OF 398
Nozzles must be able to flow at __ pressures for occupational use
Correct Answer: Low pressures