# FDNY Fire Life & Safety Director Test #2 Exam Questions & Complete A+ Graded Answers **Latest Updated 2026/2027 | Instant Download | Comprehensive FDNY FLS Director Exam Resource** Prepare for the **FDNY Fire Life & Safety Director Test #2** with this comprehensive collection of exam questions and answers covering essential **Fire Life Safety Director (FLS Director)** responsibilities, fire alarm systems, Fire Command Center procedures, fire drills, emergency evacuation, standpipe and sprinkler systems, smoke control, elevators, fire extinguishers, impairment procedures, emergency power, hot work, and NYC fire safety requirements. This resource is designed for candidates reviewing **FDNY FLS Director Test 2**, **Fire Life & Safety Director exam questions**, and important fire and emergency preparedness responsibilities. The material provides focused question-and-answer coverage of key concepts that candidates should understand when preparing for the examination. ## FDNY FIRE LIFE & SAFETY DIRECTOR TEST #2 TOPICS The material covers a broad range of important FLS Director subjects, including: ### Fire Life Safety Director Responsibilities * Fire Life Safety Director duties * FLS Director responsibilities during emergencies * Fire Command Center reporting * Fire alarm response procedures * Fire and smoke condition procedures * Emergency preparedness responsibilities * Fire FLS Brigade organization and training * Building Evacuation Supervisor training * Occupant safety and evacuation * 911 notification requirements * FLS Director supervision of fire drills * FLS Director logbook responsibilities * Fire safety staff training ### Fire Alarm Systems * Fire alarm control panel * Annunciator panels * Fire alarm initiating devices * Manual fire alarm pull stations * Fire alarm signals * Fire alarm system inspections * Fire alarm water-flow devices * Intelligent smoke detectors * Photoelectric smoke detectors * Heat detectors * Rate-of-rise heat detectors * Fire alarm trouble signals * Fire alarm logbooks * Central station transmitter * Fire alarm system testing * S-97/S-98 Certificate of Fitness holders * Fire alarm impairment procedures * Fire alarm reset procedures ### Fire Command Center * Fire Command Center procedures * FLS Director reporting requirements * Fire alarm activation response * Fire Department notification * Fire Department arrival procedures * Emergency communication * Warden communication * Auxiliary radio communication systems * Fire Command Center impairment notifications * Alarm status and system information ### Sprinkler Systems * Automatic sprinkler systems * Main control valves * Riser isolation valves * Sprinkler heads * Spare sprinkler heads * Loaded sprinkler heads * Concealed sprinkler heads * Sprinkler deflectors * Sprinkler water-flow alarms * Dry pipe sprinkler systems * Pre-action sprinkler systems * Foam-water sprinkler systems * Control valve positions * Sprinkler head clearance * Sprinkler system inspection and maintenance * Sprinkler impairment procedures * Fire Department Connections ###

Content preview

FDNY Fire Life & Safety Director Test
#2 Exam Questions Verified and
Provided with A+ Graded Answers
Latest Updated 2026

A Fire Life Safety Director should be familiar with How to manually programmed the HVAC system via the BMS (Building
which of the following EXCEPT? Management System).


When a Fire Life Safety Director is conducting fire 911
drills for the occupants, they should be instructed
to always notify first in the event of a fire
condition.


The fire triangle identifies the three needed - Oxygen
components of fires as which of the following: - Fuel
- Heat


A Deputy Fire Warden shall be provided for 7,500 square feet or part thereof
each tenancy. When the floor area of a tenancy
exceeds a certain amount of square feet of
occupied
space, a Deputy Fire Warden shall be assigned for
each:

Which of the following are associated with the - Exit access
means of egress? - Exit
- Exit discharge


Fire drills in a new office building must be Quarterly
conducted at least________in the first 2 years
following acceptance of a Comprehensive
Fire Safety and Emergency Action Plan.


During a fire drill, occupants should be instructed 911
to FIRST notify___in the event of a fire


The qualified building service employees who The Fire Life Safety Director
consists of the Fire FLS Brigade are organized,
selected and trained by:


Which type of detector will activate the Rate-of-rise heat detector
alarm when the room temperature increases at
a rapid rate (12-15 degrees F per minute)? The
alarm will reset itself, when the room
temperature returns back to normal.


The primary purpose of the_________is to process Fire alarm control panel
signals received from initiating devices and to
activate appropriate signals and outputs.


A supply of at least six spare sprinkler heads Main control valve
must be kept available on the premises near
what
location?

, _ emergency in-car operation allows fire Phase II
fighters to control the elevator, and travel to any
floor served by the elevator. The operating
controls are located inside the elevator car. Only
trained personnel or first responders should use
this feature.



What type of fire protection device will Elevator lobby smoke detectors
automatically recall elevators to the designated
landing?


If you are looking at a stairway door and notice a You're on the stair side of a door.
number on the door, which of the following is
TRUE?


After the test of smoke control system has been The manufacturer's company address
completed, the FLS Director must ensure all the
required entries are made in the FLS Logbook. The
required entries include all the following
information, EXCEPT: (Refer to the Reference
material)



The transfer of heat through solid surfaces such as Conduction
metal pipes or duct-work is called:


During a fire drill, the occupants should be At least 3 floors below their present location
advised that if fire alarm systems activate with
no additional information, they should move______.


Which of the following conditions WILL NOT result A manual fire alarm pull station activation
in an automatic release of the fail-safe locks in
a high rise building?



The standpipe system provides water that fire Risers
fighters can manually discharge through hoses
onto a fire. Water is fed into a piping system
which runs vertically (up and down) and
horizontally (side to side) throughout the
building. The piping running vertically are
usually called:

During a fire drill occupants of the building, other Not required to leave the floor
than building service employees, are:


What type of fire extinguishing system is used as a Foam-water sprinkler system
fire extinguishing medium for flammable and
combustible liquids? The water supply system is
activated by detection devices located in the same
area as the sprinklers or discharge nozzles.


In the event of fire, medical emergency, or non- Report to the Fire Command Center
fire emergency, the FLS Director must____.


Who shall authorize the placement of Impairment Coordinator
system(s) out of service that planned to be
shut down?

Document information

Uploaded on
September 3, 2026
Number of pages
9
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$16.79

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LectDeniz
5.0
(1)
Sold
21
Followers
16
Items
5281
Last sold
10 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions