FDNYC G60 Practice Exam Questions
Verified and Provided with A+ Graded
Answers Latest Updated 2026
All torch operators, an oxigen-fuel torch using any Certificate of Fitness
amount of oxigen and flamable gas and fire
guards must have a current
The Certificate of Fitness holder must regulate the pressure and flow of oxygen and natural gas to each
torch.
if the torch operator for jewelry manufacture any oxygen with any fuel gas containers, the operator must be a C of F
involves holder.
A Certificate of Fitness Holder must keep his or her on their person or otherwise readily available for inspection by any
certificate representative of the fire Department
The easiest way to extinguish a fire caused by close the shutoff valve
a leak is to
Permits issued by the FDNY are required to storing, using or handling oxygen and a flammable gas, storing, using or
conduct the following hot work: handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of
400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in
excess of 504 SCF.
For LPG, 400 SCF is approximately 47 lbs
the number of LPG containers for the storage, use, 14.1 oz = 54 cont.
handling or transportation, requiring a permit 16.4 oz = 46 cont.
20 lbs = 3 cont.
33.5 lbs = 2 cont.
40 lbs = 2 cont.
100 lbs = 1 cont.
Portable LPG containers that are more than 16.4 oz must NOT stored, handled, or used indoors in the following
and CNG containers with a capacity greater than occupancies (as defined in the Building code): residential occupancies,
8.7 SCF factory and industrial occupancies; educational occupancies;
institutional occupancies, except as the commissioner may authorize by
rule.
Site-specific permit may be a permanent permit or a temporary permit. Permanent permits
are valid for 12 months only
A city-wide permit is valid up to 30 days
, Permits shall be readily available on the premise for inspection by Fire Department
representatives.
Hot work authorization should be issued by the must be available for inspection by any representative of the
responsible person, and it department during the performance of the work, and for 48 hours after
the work is complete
FDNY permits will be posted in a central location and recorded in a log book to assist
in the coordination of construction related activities.
CNG Compressed Natural Gas.
For Citywide hot work operations, the Owner of 48
the premises must be notified in writing at least
____hours in advance prior to work beginning.
A class A fire extinguisher fights fires from Paper
How old must a candidate be in order to earn a 18 Years Old
Certificate of Fitness?
What type of fire is a Class B fire extinguisher used Oil
on?
Examples of combustibles include Newspaper
An example of a flammable material would be Gasoline
Fire extinguishers must be inspected once every Month
A work area should be Well Ventilated
A type C fire involves Live electrical equipment
Automatic sprinkler heads should be covered by a damp cloth and removed after hot work
A permit is required for storing a flammable gas in 400 scf
excess of
Acetylene burns at 3000 degrees Fahrenheit
It is dangerous to use fuel gas at pressures above 15 psi
A fire extinguisher must be mounted so that the top is not more than 5 feet off the floor
To extinguish a fire Always approach the fire from upwind
PASS stands for Pull, Aim, Squeeze, Sweep
In the case of any fire, The FDNY must be notified
For piped gas, the gas should be shut off first
Oxygen cylinders are made of Steel