Structural, Civil, Mechanical, and Electrical Concepts
Correct answers in blue
1. The 2aprimary 2apurpose 2aof 2athe 2aIllinois 2aDepartment 2aof
2aFinancial 2aand 2aProfessional 2aRegulation 2a(IDFPR) 2ain
2arelation 2ato 2aPE 2alicensing 2ais 2ato:
A. Develop 2aengineering 2atextbooks
B. Regulate 2athe 2apractice 2aand 2alicensing 2aof 2aengineers
C. Provide 2aengineering 2ascholarships
D. Design 2apublic 2ainfrastructure
Rationale: 2aThe 2aIDFPR 2aoversees 2aprofessional 2alicensure 2ato 2aensure
2apublic 2asafety 2aand 2aprofessional 2acompetency 2ain 2aengineering
2apractice.
,2. The 2a“standard 2aof 2acare” 2afor 2aa 2aprofessional 2aengineer 2ais 2adefined
2aas:
A. The 2ahighest 2alevel 2aof 2aperformance 2apossible
B. The 2alevel 2aof 2acompetence 2aordinarily 2aexercised 2aby 2aothers 2ain 2athe
2asame 2afield
C. Compliance 2awith 2aall 2aproject 2adeadlines
D. The 2alowest 2aacceptable 2astandard 2afor 2aperformance
Rationale: 2aThe 2astandard 2aof 2acare 2ais 2abased 2aon 2awhat 2aa 2areasonably
2aprudent 2aengineer 2awould 2ado 2ain 2asimilar 2acircumstances.
3. Which 2aof 2athe 2afollowing 2abest 2adefines 2aa 2a“factor 2aof 2asafety”?
A. The 2aamount 2aof 2amaterial 2asaved 2ain 2aa 2adesign
B. The 2aratio 2aof 2alive 2aload 2ato 2adead 2aload
C. The 2aratio 2aof 2afailure 2astress 2ato 2aallowable 2astress
D. The 2ainverse 2aof 2athe 2ayield 2astrength
Rationale: 2aFactor 2aof 2asafety 2aensures 2aa 2amargin 2abetween 2adesign
2astress 2aand 2afailure 2astress 2ato 2amaintain 2asafety.
4. For 2aa 2asteel 2abeam 2asubjected 2ato 2abending, 2athe 2amaximum 2astress
2aoccurs:
A. At 2athe 2aneutral 2aaxis
B. At 2athe 2aoutermost 2afiber
C. At 2athe 2acentroid
D. At 2amid-span
,Rationale: 2aBending 2astress 2avaries 2alinearly 2afrom 2azero 2aat 2athe 2aneutral
2aaxis 2ato 2aa 2amaximum 2aat 2athe 2aoutermost 2afiber.
5. The 2aethical 2aduty 2aof 2aa 2aPE 2awhen 2aa 2adesign 2aerror 2ais
2adiscovered 2aafter 2aproject 2acompletion 2ais 2ato:
A. Ignore 2ait 2ato 2aavoid 2aliability
B. Inform 2athe 2aclient 2aand 2atake 2acorrective 2aaction
C. Blame 2athe 2acontractor
D. Keep 2asilent 2aunless 2athe 2aerror 2acauses 2afailure
Rationale: 2aEngineers 2amust 2ahold 2apublic 2asafety 2aparamount 2aand
2adisclose 2aerrors 2athat 2acould 2aaffect 2asafety 2aor 2aintegrity.
6. The 2acontinuity 2aequation 2afor 2asteady 2aincompressible 2aflow 2ais:
A. P1 2a+ 2a½ρv1² 2a= 2aP2 2a+ 2a½ρv2²
B. A1V1 2a= 2aA2V2
C. Q 2a= 2aΔP/R
D. F 2a= 2ama
Rationale: 2aContinuity 2aensures 2athat 2avolumetric 2aflow 2arate 2aremains
2aconstant 2ain 2aa 2asteady 2aincompressible 2asystem.
7. The 2amoment 2aof 2ainertia 2aof 2aa 2arectangular 2asection 2a(base 2ab,
2aheight 2ah) 2aabout 2aits 2acentroidal 2aaxis 2ais:
, A. bh
B. bh³/12
C. bh²/6
D. bh³/6
Rationale: 2aThe 2acentroidal 2amoment 2aof 2ainertia 2afor 2aa 2arectangle 2ais
2abh³/12, 2afundamental 2ain 2abeam 2adeflection 2aanalysis.
8. Which 2alaw 2agoverns 2athe 2arelationship 2abetween 2acurrent,
2avoltage, 2aand 2aresistance?
A. Newton’s 2aLaw
B. Ohm’s 2aLaw
C. Kirchhoff’s 2aLaw
D. Faraday’s 2aLaw
Rationale: 2aOhm’s 2aLaw 2astates 2aV 2a= 2aIR, 2arelating 2avoltage, 2acurrent,
2aand 2aresistance 2ain 2aan 2aelectrical 2acircuit.
9. In 2areinforced 2aconcrete 2adesign, 2asteel 2areinforcement 2ais 2aprimarily
2aused 2ato:
A. Resist 2acompressive 2astress
B. Resist 2atensile 2astress
C. Improve 2aaesthetics
D. Reduce 2acreep
Rationale: 2aConcrete 2ais 2aweak 2ain 2atension, 2aso 2asteel 2areinforcement
2acarries 2athe 2atensile 2aloads.