• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 93 pages
Exam (elaborations)

Gas Fitter 2 Practice Test Exam Study Guide 2026 Complete Questions With Correct Detailed Answers || 100% Guaranteed Pass Recent Version

Document preview thumbnail
Preview 4 out of 93 pages

GAS FITTER 2 PRACTICE TEST EXAM STUDY GUIDE 2026 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || 100% GUARANTEED PASS RECENT VERSION

Content preview

Gas fitter 2 practice test
Study online at https://quizlet.com/_6v2xxx

1. A room heater installed in either a sleeping area or B
public area shall be:
A. direct vent only
B. equipped with a regulator
C. equipped with a fan
D. equipped with an on / off switch on the wall

2. What type of vent must be used when the vent of a D
wall furnace will be concealed in a partition wall?
A. B vent
B. L vent
C. BH vent
D. BW vent

3. Single wall vent connectors: D
A. may pass through floors, ceilings or roofs provided
a metal thimble is used
B. may pass through floors, ceilings or roofs provid-
ed the required minimum distance from combustible
material is maintained
C. may pass through floors, ceilings or roofs provided
they are insulated
D. shall not pass through floors, ceilings or roofs

4. BW vent shall be used only with an approved: D
A. decorative appliance
B. down flow furnace
C. revertible flue boiler
D. recessed wall furnace

5. What must be done during the installation of a gas log B
fireplace?



, Gas fitter 2 practice test
Study online at https://quizlet.com/_6v2xxx

A. Make sure there is a metal mesh screen in front of
the fireplace
B. Secure the chimney damper in the open position
C. Install a pressure regulator
D. Install a metal chimney liner

6. When can a certified hose be used to connect a con- A
struction heater to temporary piping?
A. Only if a lever handle shut off valve is installed
upstream of the hose
B. Only if the hose is 15 feet long
C. Never

7. Which of the following is acceptable when a fireplace A
insert is installed?
A. A metal chimney linear
B. The existing fireplace flue
C. BW vent
D. A tile lined fireplace flue?

8. An unvented infra-red heater can be installed in D
________ application
A. A warehouse
B. A commercial building
C. An industrial building
D. All of the above

9. Dirt pockets are required on: D
A. Decorative appliances
B. Gas logs
C. Room heaters
D. None of the available choices



, Gas fitter 2 practice test
Study online at https://quizlet.com/_6v2xxx

10. What diameter and length of a dirt pocket is required D
when a drop line is 3-inch diameter?
A. 3 inch diameter by 3 inches long
B. 1 inch diameter by 3 inches long
C. 3/4 inch diameter by 3 inches long
D. 2 inch diameter by 3 inches long

11. What type of room heater maybe installed in a bath- D
room?
A. Natural draft
B. Direct fired
C. Forced draft
D. Direct vent

12. What safety control protects a steam boiler if the con- D
densate pump fails to return water to the boiler?
A. High pressure limit control
B. Low pressure limit control
C. Flame safeguard control
D. Low water cut off

13. The relief valve for a residential low-pressure hot wa- C
ter boiler system should be?
A. 14.7 psia
B. 15 psia
C. 30 psig
D. 30 psia

14. A backflow prevent used in a boiler system should be B
located in the:
A. Over flow line connected to the drain
B. Return line close to the boiler



, Gas fitter 2 practice test
Study online at https://quizlet.com/_6v2xxx

C. 1/4" line connecting the boiler and cushion tank
D. Make up water line to the system

15. Automatic chlorinators must be installed: B
A. upstream of the heater
B. downstream of the heater
C. upstream of the filter
D. downstream of the filter

16. On seasonal start up, a pool heater should run: C
A. intermittently
B. continuously for 24 hours
C. continuously until the thermostat is satisfied
D. one hour on and one hour off until the thermostat
is satisfied

17. Before lighting a burner in a steam boiler, ensure A
that:
A. there is water in the boiler
B. the temperature controller is set properly
C. the main burner test firing valve is turned on
D. the safety valves are open

18. The recommended water temperature setting from a B
mixing valve to the domestic water system in com-
bination heating systems that employ oil-fired water
heaters for heating potable water and for space heat-
ing is:
A. 43°C (110°F)
B. 49°C to 54°C (120°F to 130°F)
C. 60°C to 66°C (140°F to 150°F)
D. 83°C (180°F)

Document information

Uploaded on
September 3, 2026
Number of pages
93
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$12.69

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BRAVOSTUVIA
4.1
(13)
Sold
86
Followers
3
Items
3527
Last sold
16 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions