4) Which of the following initiating devices must be D
replaced after it has activated?
a) rate of rise heat detector b) single action pull station
c) carbon monoxide detector d) fixed temperature heat
detector
5) A technician enters your building to work on your D
buildings multi zone standpipe system, as FLSD you
should ensure the technician possesses what
certification? (Reference Material)
a) S-97 b) w-96 c) S-11 d) S-14
6) Water dripping from an automatic ball drip, after the B
FDNY has disconnected from the FDNY connection, is
an indication of___________?
a) a defect in the FDNY Connection b) some leakage
from this valve is expected c) indicates a faulty lower
check valve d) indicates the system was overcharged
7) All of the following are signals received at the Fire C
Alarm Control Panel except?
a) alarm signal b) trouble signal c) surge signal d)
supervisory signal
8) Which of the following will not cause a recall of a D
buildings elevators?
a) smoke detector in the elevator lobby b) sprinkler
activation c) smoke detector in elevator machinery
room d) manual pull station
9) Under the 2014 building code, buildings that are D
used primarily for transacting business and rendering
professional services would be classified as____?
a) class J b) class R-1 c) Class A d) Class B
10) Which of the following is not an action to be taken D
during a fire or non fire emergency?
a) shelter in place b) in building relocation c) partial
evacuation d) Roof relocation
11) If a building has 200 sprinkler heads in it's sprinkler A
system, how many spare heads must be kept on the
premises? (Reference Material)
a) 6 b) 12 c) 24 d) 10
12) All of the following are members of the Fire and Life D
Safety Staff except?
a) Critical operations staff
b) Deputy Fire and Life Safety Director
c) Deputy Floor Warden
d) owners representative
, FLS Director's Quiz | Fire & Non-Fire Emergency Questions & Verified Answers | Fire Life Safety Director Review
13) If a buildings auxiliary radio communication system C
is out of service, a tag identifying the system as out if
service must be placed at?
a) the entrance to the building
b) at all warden phone locations
c) at the Fire command center
d) at the buildings communications center
14) Which of the following pumps is designed to D
operate when there is a slight drop in pressure due to
leakage or a pressure surge?
a) Fire Pump b) booster pump c) special service pump
d) Jockey Pump
15) The vertical portion of the system piping that C
delivers the water supply for hose connections and
sprinklers on standalone as well as combined systems is
known as:
a) cross main b) branch line c) riser d) feed main
16) The Fire Department recommends that the FLS staff B
participate in training designed to familiarize them with
their duties. The initial training in both fire and non-fire
training the training duration for FLS brigade members
should be (Both Parts):(Reference Material)
a) two hours b) three hours c) one hour d) thirty minutes
17) Which of the following would result in the shutting C
down of a buildings HVAC system?
a) manual pull station b) rate of rise heat detector c)
duct smoke detector d) area smoke detector
18) If the stem on an os&y valve is raised, this indicates a A
stanpipe system is?
a) on b) out of service c) off d) defective
19) The Temperature in the fire pump room should be B
kept at a minimum of:
a) 60 degrees b) 40 degrees c) 32 degrees d) 50
degrees
20) The most common standpipe system in operation is: B
a) dry standpipe with automatic dry pipe valve b) wet
standpipe c) dry standpipe with no permanent water
supply d) yard system
, FLS Director's Quiz | Fire & Non-Fire Emergency Questions & Verified Answers | Fire Life Safety Director Review
1- Upon implementation of the FDNY plan or during the B
drills, the FLS Director must identify themselves to
building occupants and others by?
a- standing at the fire command station.
b- donning a vest, armband, or other form of
identification indicating their role.
c-responding to the location of the reported
emergency.
d-meeting the fire department outside
2- In the event of a fire, a medical emergency or other E
non-fire emergency in the building, the FLS Director
must?
a. Always report the fire command stationb. implement
such fire safety and/or non-fire emergency actions as
are warranted by the circumstances, in accordance with
the provisions of the FDNY Plan, the Fire Code, and the
Fire Rules; c. notify arriving emergency response
personnel of the nature of the emergency and the
response thereto; and d. comply with the directions of
the emergency response personnel and/or other lawful
authority. e. All of above
3- Select the correct statement regarding Building C
Evacuation Supervisor (BES).
a. BES is authorized to perform FLS Director's duties
when the FLS Director is out for lunch.
b. BES is required to possess a Certificate of Fitness.
c. BES is allowed to perform FLS Director's duties in
office buildings outside regular business hours.
d. BES is responsible to train FLS staff.