Question:
Properly sealed septic tanks are?
Answer:
vented through the building plumbing
Question:
The liquid depth of a septic tank?
Answer:
must be at least 30 inches
Question:
Which of the following is true of a septic tank with 15 inches of cover??
Answer:
it must have an access port with a riser
Question:
Which if the following is acceptable for the line from the building to the treatment
tank??
Answer:
cast iron, SDR 26 plastic pipe, and Schedule 40 plastic pipe
Question:
Most of the settable solids and scum that enter a properly designed septic tank will be?
Answer:
removed in the first compartment
, Question:
Which of the following should a house sewer have??
Answer:
A two way sanitary clean-out, minimum 1/8 inch per foot fall, minimum diameter of 3
inches
Question:
Which of the following applies if effluent is to be pumped??
Answer:
A high-water alarm must be provided, the pump must be installed in a separate
chamber, a check valve should be in line if the disposal area is upgrade
Question:
T/F: Septic tanks may be 1.5 inch-thick steel?
Answer:
F
Question:
T/F: Septic tanks may be reinforced fiberglass?
Answer:
T
Question:
T/F: Two single-compartment septic tanks in series are allowed?
Answer:
T
Question:
How many spray heads would be needed for an older four bedroom home without
water-saving devices in Beaumont, Texas (note: extreme southeast Texas) to meet
minimum requirements for spray are is rotary heads sent out a spray 30 feet??
Answer:
4
Verified Solutions Latest Update
Question:
Properly sealed septic tanks are?
Answer:
vented through the building plumbing
Question:
The liquid depth of a septic tank?
Answer:
must be at least 30 inches
Question:
Which of the following is true of a septic tank with 15 inches of cover??
Answer:
it must have an access port with a riser
Question:
Which if the following is acceptable for the line from the building to the treatment
tank??
Answer:
cast iron, SDR 26 plastic pipe, and Schedule 40 plastic pipe
Question:
Most of the settable solids and scum that enter a properly designed septic tank will be?
Answer:
removed in the first compartment
, Question:
Which of the following should a house sewer have??
Answer:
A two way sanitary clean-out, minimum 1/8 inch per foot fall, minimum diameter of 3
inches
Question:
Which of the following applies if effluent is to be pumped??
Answer:
A high-water alarm must be provided, the pump must be installed in a separate
chamber, a check valve should be in line if the disposal area is upgrade
Question:
T/F: Septic tanks may be 1.5 inch-thick steel?
Answer:
F
Question:
T/F: Septic tanks may be reinforced fiberglass?
Answer:
T
Question:
T/F: Two single-compartment septic tanks in series are allowed?
Answer:
T
Question:
How many spray heads would be needed for an older four bedroom home without
water-saving devices in Beaumont, Texas (note: extreme southeast Texas) to meet
minimum requirements for spray are is rotary heads sent out a spray 30 feet??
Answer:
4