SECTION 1: BOILER FUNDAMENTALS AND DEFINITIONS
(Questions 1-20)
1. What is the maximum allowable working pressure (MAWP) for a
low-pressure steam boiler?**
A) 10 psig
B) 15 psig
C) 30 psig
D) 50 psig
,Correct Answer: B) 15 psig
*Rationale: A low-pressure steam boiler operates at a steam or vapor
pressure of 15 psig or less. This is a fundamental definition that
appears frequently on the exam .
2. What is the maximum allowable working pressure (MAWP) for a
low-pressure hot water boiler?**
A) 100 psig
B) 125 psig
C) 160 psig
D) 200 psig
Correct Answer: C) 160 psig
*Rationale: Low-pressure hot water boilers operate at pressures not
exceeding 160 psig and temperatures less than 250°F. This is a critical
threshold to know for the exam .*
---
**3. What is the maximum temperature allowed for a low-pressure
hot water boiler?**
A) 200°F
B) 212°F
C) 250°F
D) 300°F
,Correct Answer: C) 250°F
*Rationale: Low-pressure hot water boilers must operate at
temperatures below 250°F. This is a key regulatory threshold .*
**4. How many square feet of heating surface equals one boiler
horsepower for conventional boilers in Minnesota?**
A) 5 sq. ft.
B) 10 sq. ft.
C) 15 sq. ft.
D) 20 sq. ft
Correct Answer: B) 10 sq. ft.
*Rationale: For the purpose of rating boiler horsepower for an
Engineer's License in Minnesota, 10 square feet of boiler heating
surface equals one boiler horsepower on a conventional boiler .*
---
**5. A Minnesota Special Engineer license authorizes the holder to be
in charge of boilers up to what horsepower limit?**
A) 25 HP
B) 50 HP
C) 75 HP
D) 100 HP
, Correct Answer: B) 50 HP
*Rationale: A Special Engineer license allows the holder to take
charge of high and low pressure boilers not exceeding a total of 50
boiler horsepower .*
**6. A Special Engineer may serve as a shift engineer in a plant of
what size?**
A) 50 HP
B) 75 HP
C) 100 HP
D) 150 HP
Correct Answer: C) 100 HP
*Rationale: A Special Engineer may serve as a shift engineer in a plant
up to 100 horsepower .
---
**7. What is the passing score for a Minnesota boiler engineer license
examination?**
A) 60%
B) 65%
C) 70%
D) 75%