1. A master electrician is installing a new 120/240-volt, single-phase
service for a detached commercial building. The service
disconnecting means is located immediately inside the building
where the service conductors enter. During inspection, the inspector
notes that the grounded conductor is bonded to the service
enclosure, while the equipment grounding conductors for
downstream feeders are isolated from the grounded conductor.
What is the fundamental reason for this arrangement?
A. It increases the ampacity of the grounded conductor.
B. It prevents objectionable current from normally flowing on
equipment grounding paths downstream of the service disconnect.
C. It allows the equipment grounding conductor to carry continuous
neutral current.
D. It eliminates the requirement for grounding electrode conductors.
Answer: B.
Rationale: The service disconnect is the point where the grounded
conductor is bonded to the service equipment and grounding electrode
system. Downstream of that point, the grounded and equipment
grounding conductors are separated so normal load current does not
flow on equipment grounding paths, metal enclosures, raceways, or
1
,other conductive parts. Maintaining this separation is fundamental to
preventing objectionable current and preserving an effective fault-
current path.
2. A feeder supplies a 120/208-volt, three-phase panelboard. The
feeder consists of three ungrounded conductors, one grounded
conductor, and one equipment grounding conductor. At the
panelboard, an installer installs the grounded conductor bonding
screw supplied with the panel. What is the primary problem with
this installation?
A. The feeder neutral is too large.
B. The equipment grounding conductor becomes unnecessary.
C. The panelboard is converted into service equipment even though it is
supplied by a feeder.
D. The grounded conductor and equipment grounding conductor are
improperly interconnected downstream of the service disconnect.
Answer: D.
Rationale: A panelboard supplied by a feeder is generally downstream
of the service disconnect. The grounded conductor must remain
isolated from the equipment grounding/bonding system at such a
panel. Installing the bonding screw creates a parallel path for neutral
current through the equipment grounding conductor, raceway, and
metal enclosures.
3. A 20-ampere branch circuit supplies several receptacles in a
commercial office. The electrician intends to use 14 AWG copper
conductors because the actual calculated load is only 12 amperes.
Which statement is most accurate?
2
,A. The 14 AWG conductors are permissible because the calculated load
is below 15 amperes.
B. The conductor size is determined only by the connected load.
C. The branch-circuit conductors must generally have ampacity
appropriate for the 20-ampere circuit, so 14 AWG copper cannot
ordinarily be used merely because the calculated load is 12 amperes.
D. The electrician can use 14 AWG if the receptacles are rated 15
amperes.
Answer: C.
Rationale: The rating of the overcurrent protective device and the
conductor ampacity must be coordinated according to the applicable
NEC requirements. A 20-ampere branch circuit ordinarily requires
conductors capable of carrying the required current; simply having a
measured or calculated load below 15 amperes does not automatically
authorize reducing the conductor to 14 AWG.
4. A conductor is being installed in a raceway containing several
other current-carrying conductors. The electrician calculates the
adjustment factors before selecting the conductor size. Why is
conductor adjustment necessary?
A. Heat generated by multiple current-carrying conductors can reduce
the conductor's ability to dissipate heat.
B. Multiple conductors always increase conductor voltage rating.
C. Adjustment is required only when conductors are aluminum.
D. Adjustment eliminates the need for overcurrent protection.
Answer: A.
Rationale: Current flowing through conductors generates heat. When
multiple current-carrying conductors are grouped together, heat
dissipation becomes less effective. NEC ampacity adjustment
3
, provisions account for this thermal condition. The adjusted ampacity
must then be evaluated along with ambient-temperature correction
and the applicable termination limitations.
5. An electrician is terminating a copper conductor under a listed
pressure terminal. The conductor is inserted properly, but the
terminal is tightened only finger-tight because the electrician is
concerned about damaging the terminal. What is the most serious
concern?
A. The conductor will automatically become oversized.
B. The conductor may have excessive impedance and overheating at the
termination because of inadequate contact pressure.
C. The circuit will become grounded.
D. The conductor will necessarily exceed its voltage rating.
Answer: B.
Rationale: Electrical terminations depend upon proper mechanical
and electrical contact. An improperly torqued connection can develop
increased resistance, resulting in localized heating, voltage drop,
arcing, equipment damage, and potentially fire. Listed equipment
instructions and specified torque values must be followed where
applicable.
6. A 120-volt branch circuit is installed in a metal raceway. The
electrician installs an equipment grounding conductor even though
the raceway itself is permitted to serve as an equipment grounding
conductor. What is the best explanation?
A. The additional conductor automatically increases branch-circuit
ampacity.
B. An equipment grounding conductor is never permitted inside metal
4