Prepare for the NICET Fire Alarm Systems Level 2 exam with comprehensive Q&A, practice questions, verified answers, and detailed explanations. This resource is designed to help you review key fire alarm system concepts, strengthen your knowledge, and prepare effectively for the Level 2 certification exam.

Content preview

NICET - Fire Alarm Systems (Level 2) Q&A
NICET - Fire Alarm Systems (Level 2)
Study online at https://quizlet.com/_h9og07

1. The International Mechanical Code requires a duct 2000 cfm
smoke detector in the return for units over ________
cfm

2. The International Mechanical Code (IMC) requires a 15000
duct smoke detector in the supply for units over
__________ cfm

3. Digital alarm communicator transmitters (DACT) 4 hours
which use call forwarding to the DACR shall be tested
with what frequency?

4. NPLFA cables shall be insulated to __________ v 600v

5. PLFA cables shall be insulated to _______ v 300v

6. For sprinkler systems what type of signal is a fire d
pump running?
a. alarm
b. supervisory
c. trouble
d. A and B

7. A positive alarm sequence requires the approval of the AHJ
___________.

8. How often shall a remote annunciator used at the Semniannually
main entrance of a low-rise residential apartment
building be inspected?

9. According to NFPA 72, the off-normal signal of a tam- Normal
per switch control valve used in sprinkler piping that
is required for pressure-actuated water flow alarm



, NICET - Fire Alarm Systems (Level 2) Q&A
NICET - Fire Alarm Systems (Level 2)
Study online at https://quizlet.com/_h9og07

switch, shall not be restored at any valve position ex-
cept _____________?

10. When installing a heat-sensing fire detector on the 12 in; 8 ft
bottom of a beam, the beam must be less than
_____________ inches in depth and _____________ feet on
center?

11. Where a door is released to provide a 2-hour fire rating b
directly from the smoke detector, the detector shall be
______________
a. mounted as close as possible to the door being
released
b. listed for door releasing service
c. identified for door releasing service
d. of the photoelectric type only

12. According to NFPA, smoke detectors installed in the d
ducts of HVAC systems shall initiate:
a. alarm
b. supervisory
c. trouble
d. a or b

13. According to the IBC, shop drawings shall include: d
a. floor plan that indicates the use of all rooms
b. annunciators
c. voltage drop calculations
d. all of the above

14. The location of remotely located power supplies shall Master Control Unit
be identified at the ________________



, NICET - Fire Alarm Systems (Level 2) Q&A
NICET - Fire Alarm Systems (Level 2)
Study online at https://quizlet.com/_h9og07

15. Heat detectors will be installed in an elevator hoist- lower; 24 in
way to shut down power to the elevator prior to
sprinkler activation. The heat detectors need to have
a _______________ temp rating and shall be located
______________ in from the sprinkler head.

16. A local community college is what type of occupancy Group B
classification?

17. What type of occupancy group for a school below the Group E
12th grade?

18. What type of occupancy group for a school above the Group B
12th grade?

19. A pathway shall be designated as _______________ (what Class E
class?) when it is NOT monitored for integrity?

20. Manual fire alarm boxes shall be installed on both 40 feet; 5 feet
sides of grouped openings over ____________ feet in
width and within __________ feet of each side of the
grouped opening.

21. A fire pump was installed in a low-rise residential c
building with a required fire alarm system. What are
the requirements for the pump running signal?
a. It shall be a supervisory signal.
b. It shall be an alarm signal.
c. It shall be a supervisory or alarm signal.
d. A pump running signal is not required.

22. A licensed electrician was hired to install duct detec- d
tors mounted on the air ducts of a 5,000 CFM unit.



, NICET - Fire Alarm Systems (Level 2) Q&A
NICET - Fire Alarm Systems (Level 2)
Study online at https://quizlet.com/_h9og07

Which of the follwoing statements is true?
a. The smoke detector must be listed for use in air
ducts
b. The detectors can initiate a supervisory signal
c. The detectors can initiate an alarm signal
d. All of the above

23. Record drawings, as-builts, shall contain approval doc- d
umetnation resulting from any _______________?
a. variances
b. performance-based designs
c. risk analysis
d. all of the above

24. An electrically locked door is connected to the fire No
alarm system in order to unlock in the event of an
alarm. The customer has requested that a feature be
added (push button) to lock the doors even while in
alarm. Is this permitted by code?

25. According to the 2022 edition of NFPA 13, electric wa- 90 seconds
terflow devices must activate within _________________
of water flow beginning and continue until the flow
stops

26. According to teh IBC, strobe lights/appliances shall Elevator cars
not be required in ______________?

27. Communications wires (Coaxial cables) shall have a 300v
voltage rating of not less than _________ volts

28. What is the minimum workspace width in front of 30 in
electrical equipment (This allows enough room for a

Document information

Uploaded on
August 21, 2026
Number of pages
59
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
allowaysbest
4.6
(853)
Sold
2408
Followers
14
Items
972
Last sold
18 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions