Question: A frequency that has been amplified to four frequencies is called
Answer: frequency multiplex

Question: Class 1 circuits are allowed a minimum wire size of
Answer: 18 awg

Question: According to the NEC class III circuits are allowed a minimum wire size of?
Answer: 18 awg

Question: Class three circuits are all allowed a minimum of
Answer: 18 awg

Question: On transmitting stations what is the smallest size copper grounding conductor that would be
permitted?
Answer: 10 awg

Question: What is the minimum size grounding conductor for communication circuits?
Answer: 14 awg

Question: interconnections on a solar photovoltaic system?
Answer: 18 awg

Question: You will find difficulty using UF cable as a ground because?
Answer: Trenching and corrosion damage

Question: What type of wire is to be used for common direct burial?
Answer: USE

Question: Type CMUC communications wires and cables shall be permitted to be installed where?
Answer: under carpet

Question: Interconnecting cables under raised floors that support information shall be type?
Answer: DC

Question: What type of cable is permissible on module interconnections within a photovoltaic array that are
exposed to the weather?
Answer: USE-2

Question: moisture and heat resistance wire is
Answer: THW

Question: Which of the following is the best choice for risers in CATV or radio distribution systems?
Answer: CMR or CATVR

,Question: Type OFNG and OFCG shall be listed as being suitable for general purposes use with the exception of
risers and plenums and shall be listed as being?
Answer: Resistant to the spread of fire

Question: In a class II power limited circuit what is the cable of choice for a plenum?
Answer: CL2P

Question: An electrical conduit buried 18" below grade shall have warning tape at how many inches
above the conduit?
Answer: 12 inches

Question: What is the minimum required separation between communication cables and lighting conductors?
Answer: 6 ft

Question: Landscape lighting buried a minimum of
Answer: 6 inches

Question: Raceways cable trays and other wiring methods for intrinsically safe system wiring shall be identified
with permanently affixed labels with the wording intrinsic safety wiring at what maximum spacing?
Answer: 25 ft

Question: All of the following are acceptable as a ground except?
Answer: 10 ft gas pipe

Question: Ariel Communication cable should not be connected to same arm as high voltage, and should
maintain a minimum separation of
Answer: 12'' from high voltage.

Question: minimum length of a grounding rod
Answer: 8 ft

Question: Coax entering a building should be grounded within
Answer: 30' of entrance.

Question: What is the color of an equipment ground wire?
Answer: Green with yellow stripes

Question: Which of the following affects the resistance of a conductor?
Answer: material

Question: A current that leaves its intended path and returns to the source bypassing the load causes the
circuit to be?
Answer: shorted

Question: the grounding bus shall be connected?
Answer: Through the green colored antiquated conductor

, Question: Cable is being installed in an area that is above a suspended ceiling that contains completely
enclosed air ducts. What term or word identifies this location?
Answer: accessible

Question: According to the NEC electrical equipment may not be mounted on concrete, cinder block, or brick
walls with?
Answer: wooden plugs

Question: What is the function of the green wire in a manufactured home?
Answer: grounding connection

Question: Where are splices allowed in conductors in surface mount raceways if they do not have removable
covers?
Answer: only in junction boxes

Question: Insulated conductors of #6 or smaller intended for use as grounding conductors in a circuit must be
either of the following colors?
Answer: White, gray, or have three continuous white stripes on other than green insulation

Question: What percent of fill is allowed in a conduit with three conductors?
Answer: 40%

Question: Which of the following is an acceptable marking method for the grounding conductor on a grounding
type receptacle?
Answer: A green colored hexagon, headed screw or nut

Question: What is the maximum allowable output of a class I power limited circuit?
Answer: 1000 VA

Question: Supply circuits and interconnecting cable under raised floors supplying information technology
equipment in a data processing room must be?
Answer: accessible

Question: The best type of connection to electrode rod ground are
Answer: listed clamps

Question: Over head runs should be no less than
Answer: 8 feet about the roof tops

Question: On a multi conductor cable what is the outer layer called?
Answer: jacket

Question: Telecom wire grounded on each end what is the electrical path called?
Answer: ground loop

Question: Locations where easily ignitable fibers are stored are?
Answer: Class III division II

Document information

Uploaded on
August 21, 2026
Number of pages
17
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Martinclinton
2.0
(2)
Sold
19
Followers
0
Items
4049
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions