1|Page
CSA W47.1 AND CSA W59 EXAM
2026| CERTIFIED QUESTIONS AND
ANSWERS
On statically loaded structures scanning levels for Ultrasonic Testing, for sound
path distances 63 to 125 is: - correct-answer - +19
Ultrasonic Inspection of dynamically loaded structures, for defects having a rating
of +10.5 on 32 mm steel plate, the maximum allowable size is: - correct-answer -
Reject, regardless of the length.
Radiographic Inspection on structure loaded 32 mm steel plate, the maximum
allowable size of a slag line for tension loaded structures is: - correct-answer - 10
mm
,2|Page
Beam splices of tension members, made by groove welds shall be: - correct-
answer - Complete joint penetration
This standard shall be administered by: - correct-answer - the bureau
An individual who welds by manipulating an electrode holder or welding gun: -
correct-answer - welder
All tests on fluted materials such as decking shall be performed on material or
_________ less in thickness. - correct-answer - 3mm
For "S" classification for GTAW, the welder must stop, start in the root of the
fillet: - correct-answer - option 1 only
, 3|Page
The number of test specimens required for "S" classification, MCAW process,
Class "V", option 3 is: - correct-answer - 3
6. Undercut shall not be more than _____ deep occurring in test samples. -
correct-answer - l mm
The maximum size discontinuity permitted in a weld with 20 mm effective throat
is: - correct-answer - 6mm
A welding supervisor, a graduate of the WET Program, shall have a minimum
of_____ years of welding-related experience pertinent to the
company's type of operations. - correct-answer - 3
CSA W47.1 AND CSA W59 EXAM
2026| CERTIFIED QUESTIONS AND
ANSWERS
On statically loaded structures scanning levels for Ultrasonic Testing, for sound
path distances 63 to 125 is: - correct-answer - +19
Ultrasonic Inspection of dynamically loaded structures, for defects having a rating
of +10.5 on 32 mm steel plate, the maximum allowable size is: - correct-answer -
Reject, regardless of the length.
Radiographic Inspection on structure loaded 32 mm steel plate, the maximum
allowable size of a slag line for tension loaded structures is: - correct-answer - 10
mm
,2|Page
Beam splices of tension members, made by groove welds shall be: - correct-
answer - Complete joint penetration
This standard shall be administered by: - correct-answer - the bureau
An individual who welds by manipulating an electrode holder or welding gun: -
correct-answer - welder
All tests on fluted materials such as decking shall be performed on material or
_________ less in thickness. - correct-answer - 3mm
For "S" classification for GTAW, the welder must stop, start in the root of the
fillet: - correct-answer - option 1 only
, 3|Page
The number of test specimens required for "S" classification, MCAW process,
Class "V", option 3 is: - correct-answer - 3
6. Undercut shall not be more than _____ deep occurring in test samples. -
correct-answer - l mm
The maximum size discontinuity permitted in a weld with 20 mm effective throat
is: - correct-answer - 6mm
A welding supervisor, a graduate of the WET Program, shall have a minimum
of_____ years of welding-related experience pertinent to the
company's type of operations. - correct-answer - 3