1. In a large NYC Health + Hospitals facility, the Supervising HVAC
Technician receives reports that several patient rooms in a critical care
unit are maintaining temperatures within the required range, but
humidity levels are consistently above design specifications. After
confirming that room thermostats are functioning correctly, which of
the following should be investigated first because it is most directly
responsible for controlling humidity?

A. Supply fan motor horsepower
B. Building lighting circuits
C. Cooling coil performance and chilled water or refrigerant conditions
D. Return air grille finish

,Rationale: Humidity removal primarily occurs as air passes over a properly
functioning cooling coil. If the coil temperature is not sufficiently low due to
inadequate chilled water flow, refrigerant issues, fouling, or control
problems, moisture removal decreases even when room temperatures
appear acceptable.

2. A hospital air-handling unit experiences increasing differential pressure
across the filter bank. What is the most appropriate supervisory
action?

A. Increase supply fan speed indefinitely
B. Disable the filter differential pressure alarm
C. Schedule filter replacement while monitoring airflow and system
performance
D. Close all outside air dampers

Rationale: Rising pressure drop across filters indicates loading. Replacing
filters restores airflow, improves energy efficiency, and maintains indoor air
quality while avoiding unnecessary stress on the fan system.

3. A supervisory HVAC technician reviewing maintenance records notices
repeated failures of the same chilled water pump bearing. Which
action best reflects effective preventive maintenance management?

A. Continue replacing bearings only
B. Ignore the failures until pump replacement
C. Investigate root causes such as alignment, lubrication, vibration, and

,operating conditions
D. Increase pump operating speed

Rationale: Repeated failures indicate an underlying issue. Supervisors
should identify and eliminate the root cause rather than repeatedly
replacing failed components.

4. During an inspection of a VAV system, several terminal boxes fail to
respond to thermostat adjustments. Which component should be
checked first?

A. Chilled water expansion tank
B. Steam trap
C. Actuator and control signal
D. Cooling tower fill

Rationale: VAV box operation depends on a functioning actuator receiving
the proper control signal. Mechanical or electrical failures at this point
commonly prevent damper movement.

5. Which maintenance activity most effectively improves the efficiency of
an air-cooled condenser?

A. Painting the condenser housing
B. Tightening electrical conduit straps
C. Cleaning condenser coils to improve heat transfer
D. Increasing refrigerant pressure

, Rationale: Dirty condenser coils reduce heat rejection, increasing
compressor workload and energy consumption. Cleaning restores efficient
heat transfer.

6. A centrifugal fan begins producing excessive vibration after scheduled
maintenance. Which condition is the most likely cause?

A. Properly balanced wheel
B. Correct belt tension
C. Misalignment or an unbalanced rotating assembly
D. Closed access doors

Rationale: Excessive vibration following maintenance commonly results
from improper alignment, wheel imbalance, or incorrect installation
procedures.

7. Which HVAC system component prevents reverse refrigerant flow
when the compressor stops?

A. Receiver
B. Accumulator
C. Check valve
D. Sight glass

Rationale: Check valves permit refrigerant flow in one direction and
prevent reverse migration that could negatively affect system operation.

Document information

Uploaded on
August 11, 2026
Number of pages
40
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$24.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Guestt
4.4
(5)
Sold
11
Followers
0
Items
2091
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions