Arizona Contractor License CR-67 2026/2027 Test Exam 170
comprehensive questions |RECENT AND FREQUENTLY MOST
TESTED QUESTIONS AND VERIFIED SOLUTIONS/GET IT 100%
ACCURATE!! 2026!!
Exam coverage for the Arizona Contractor License CR-67 - Low Voltage Communication
Systems includes the technical knowledge, business practices, safety requirements, and
Arizona contractor regulations applicable to contractors performing low-voltage
communication systems work. The Arizona Registrar of Contractors identifies CR-67 as the
dual commercial/residential classification covering the scopes of both C-67 Low Voltage
Communication Systems and R-67 Low Voltage Communication Systems
The frequency of AC is measured in? - correct answer-Measured in hertz Hz
What refers to a voltage can convey information? - correct answer-Electrical Signal
What refers to the maximum voltage that can be reached by a signal? - correct answer-Amplitude
Electricity may flow only when? - correct answer-There has to be a for it to return making a complete
circuit
Alternating Current (AC) always flows one way then the other? - correct answer-True. AC always
flows one way then the other.
What is the return path for electrical power to flow back to the service panel? - correct
answerNeutral
The live wire is always ungrounded? - correct answer-True. They are very hot caring electrical power
A ground electrode conductor originates at the neutral or equipment ground bus of the service
panel? - correct answer-True
A ground electrode should not be made in contact with the earth? - correct answer-False. sound be
on contact with the earth
,07 August 2026
Compare Watts with Voltage - correct answer-Watts are the measure of power. Voltage is the
measure of potential energy.
You should size conductors no less ______ of the continuous loads plus _________ of the
noncontinuous loads,. - correct answer-125% / 100%
Conductor sizes are often expressed in? - correct answer-American Wire Gage (AWG)
What refers to the allowable current-carrying capacity of a conductor? - correct answer-Ampacity
The insulation type determines the areas the writers can and cannot used? - correct answer-True
RHH wires use rubber insulation that is high heat resistant and is good in? - correct answer-Is only
good in dry locations.
RHW-2 wires use the rubber insulation but are suitable for wet locations? - correct answer-True
What cables can be used inside wall, ceiling or under the floor. - correct answer-Non-metallic (NM)
What cables are most appropriate for damp areas? - correct answer-Underground feeder (UF) or
Non-metallic Wet underground (NMWU)
THWN means? - correct answer-Flame retardant, Heat resistant, Moisture resistant, Gasoline
resistant, and oil resistant.
An insulated grounded conductor which is ____ AWG or below should be identified by a continuous
white or gray outer finish. - correct answer-6 AWG
What is the amount of voltage measured between any two line conductors of a balanced threephase
system. - correct answer-Line voltage
What describes the voltage measured across any one component of a balanced three-phase system.
- correct answer-Phase Voltage
, 07 August 2026
A _______ is unintentional mess up. - correct answer-Ground Fault
An effective Ground-Fault current path is? - correct answer-An effective Ground-Fault current paths
a path intentionally constructed to facilitate the operation of the overcurrent protective devices
currently in place.
GFCI is never sensitive to small "leaks" of current - correct answer-False. GFCI = ground-fault circuit
interrupter
Grounding and bonding means exactly the same thing? - correct answer-False. Bonding is a means of
allowing electrical continuity between metallic objects.
A typical work space (for a working voltage under 600V) should have a minimum headroom of
______ m. - correct answer-2.0 m
typically there are ____ hot wires running from the utility company into the service panel. - correct
answer-2
A service disconnect need to have a rating which is? - correct answer-No less than that the calculated
load or for the type of installation
Fast- blow fuses tend to open real quick when the rated current is reached. - correct answer-True
System grounding is required when you have a supply transformer of a SOV or lower system? -
correct answer-System grounding is required when you have a supply transformer of a 50V or lower
system which itself is supplied from a source over 150V to the ground
On a class 1 circuit it is ok to use smaller wire sizes than normal power circuits such as. - correct
answer-Anything 16 AWG or lower
Class 1 signaling and remote control circuits are limited too? - correct answer-600 Volts
When a circuit controls equipment can introduce a direct life safety hazard, the circuit has to be? -
correct answer-Class 1