Texas Fire Sprinkler Inspector License EXAM QUESTIONS AND
CORRECT VERIFIED SOLUTIONS LATEST UPDATE THIS YEAR –
JUST RELEASED
Texas Fire Sprinkler Inspector License Exam
Exam Coverage at a Glance (10 Key Points)
1. Licensing Authority - Regulated by Texas State Fire Marshal's Office (SFMO) under Texas
Insurance Code Chapter 6003; plumbing inspector endorsements governed by Texas
State Board of Plumbing Examiners (TSBPE)
2. RME Inspector License - RME-General Inspector allows ONLY inspection, testing, and
maintenance (ITM) services; NOT installation, planning, or design work
3. Residential Sprinkler Endorsement - 24-hour training course required; $40 exam fee;
requires current Journeyman/Master/Inspector Plumber license
4. Key NFPA Standards - NFPA 13 (installation), NFPA 25 (ITM), NFPA 13D/R (residential),
NFPA 14 (standpipes), NFPA 20 (pumps), NFPA 24 (underground mains)
5. Inspection Definition - Visual examination of system or portion thereof; includes
verifying clearance (minimum 6" from combustible materials), head obstruction, and
general condition
6. Report Delivery - Results sent within 30 days of exam or 14 days after testing service
reports; performance analysis available upon written request for failures
7. License Display - Certificate of Registration displayed conspicuously at place of business;
required on bids, proposals, install drawings; 1" lettering on vehicles
8. RME Role Requirements - Registered firms must have designated RME to assure systems
meet legal standards; RME death/disassociation allows 30-day continuation
9. Financial Responsibility - General liability requirements: $100,000 combined single limit;
$300,000 aggregate; must include products and completed operations
10. Insurance Code Chapter 6003 - State Fire Marshal has authority over fire sprinkler
system service and installation licensing; exam questions include statutes, administrative
rules, and national codes
250 Multiple Choice Questions with Rationales
Question 1
, Page 2 of 145
Under the Texas Insurance Code Chapter 6003, which entity has primary authority for
licensing fire protection sprinkler system service and installation?
A) Texas State Board of Plumbing Examiners
B) Texas Commission on Fire Protection
C) Texas State Fire Marshal's Office
D) Texas Department of Licensing and Regulation
Answer: C
Rationale: The State Fire Marshal's Office (SFMO) under the Texas Department of Insurance has
primary authority for fire sprinkler licensing under Texas Insurance Code Chapter 6003. The
Texas State Board of Plumbing Examiners handles plumbing licensing and endorsements, while
TCFP handles fire inspector certification. The exam is based on this statutory framework .
Question 2
According to Texas regulations, which NFPA standard primarily governs the inspection,
testing, and maintenance (ITM) of water-based fire protection systems?
A) NFPA 13
B) NFPA 25
C) NFPA 72
D) NFPA 10
Answer: B
, Page 3 of 145
Rationale: NFPA 25 is the Standard for the Inspection, Testing, and Maintenance of Water-Based
Fire Protection Systems. It provides the requirements for routine visual inspections, testing
procedures, and maintenance schedules. NFPA 13 covers installation, NFPA 72 covers fire
alarms, and NFPA 10 covers portable fire extinguishers .
Question 3
What is the minimum clearance required between a sprinkler deflector and combustible
materials under NFPA 13?
A) 6 inches
B) 12 inches
C) 18 inches
D) 24 inches
Answer: A
Rationale: NFPA 13 requires a minimum clearance of 6 inches between the sprinkler deflector
and any obstruction or combustible material to ensure proper water distribution . This
clearance is critical for the sprinkler's spray pattern to develop properly.
Question 4
During an inspection of a wet pipe system, the water pressure is measured at 50 psi, but the
system requires a minimum of 60 psi. What is the proper course of action?
, Page 4 of 145
A) Document the reading and continue
B) Immediately shut down the system
C) Notify maintenance that corrective action is required
D) No action is needed as pressure fluctuates normally
Answer: C
Rationale: Sprinkler systems must maintain adequate pressure to function properly.
Substandard pressure requires corrective action. The inspector should notify maintenance
personnel to investigate and address the low pressure issue .
Question 5
What is the maximum spacing allowed for standard pendent sprinklers in an ordinary hazard
occupancy according to NFPA 13?
A) 8 feet
B) 12 feet
C) 15 feet
D) 20 feet
Answer: C
Rationale: NFPA 13 specifies a maximum spacing of 15 feet for standard pendent sprinklers in
ordinary hazard occupancies to ensure adequate coverage . Different occupancy classifications
may have different spacing requirements.