BICSI Comprehensive Resource To Help You Ace Exams Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS Guaranteed Pass First Attempt!! Current Update!! 1. What should be done FIRST when pulling a cable across an open ceiling? - Correct Answer: Assess route across ceiling 2. An ______ is where a primary bonding bussbar (PBB) should be used - Correct Answer: EF 3. If you terminate Category 6 cable onto Category 6A patch panels and use Category 5e patch cords, the overall performance rating of the channel is? - Correct Answer: Category 5e 4. When the labeling scheme is based upon the customer's requirements, it is advisable to obtain the documentation in the form of a? - Correct Answer: Cut sheet 5. When installing backbone cabling, labels should be within ________ of the connecting hardware terminated to the cabling - Correct Answer: 305mm (12in) 6. The IEEE 802.11 standard relates to? - Correct Answer: Wireless LANs 7. Two 90 degree bends are allowed in any one conduit segment, a third bends may be acceptable under certain circumstances, the following are acceptable:___________ - Correct Answer: Conduit is increased to the next trade size, the conduit does not exceed 10m (33ft) 8. The copper cable category with its bandwidth limits: _________ - Correct Answer: Cat 5-100Mhz, Cat 5e-100Mhz,Cat6- 250 Mhz, Cat6A-500 Mhz 9. When using cable management, care should be used to select management that protects:_______ - Correct Answer: Minimum bend radius 10. When atmospheric testing a confined space prior to entering, the following ranges indicate a safe oxygen level:_______ - Correct Answer: Between 19.5% and 23.5% 11. If the ICT installer is installing a fire stop assembly, the only way to properly install the assembly would be per:_____ - Correct Answer: Manufacturers directions 12. The two following models a re conductor splice connectors used for copper cabling:______________ - Correct Answer: straight through and Butt 13. Modular connectors can generally accommodate:____________ - Correct Answer: 22 to 28 AWG 14. What are characteristics of insertion loss? - Correct Answer: Insertion loss increases with temperature, frequency, and cable length 15. __________ has significant drawbacks with regard to distribution and is not generally recommended as a horizontal cabling solution - Correct Answer: The poke-thru method

Content preview

BICSI

Comprehensive Resource To Help You Ace 2026-2027 Exams
Includes Frequently Tested Questions With ELABORATED
100% Correct COMPLETE SOLUTIONS

Guaranteed Pass First Attempt!! Current Update!!


1. What should be done FIRST when pulling a cable across an open ceiling? -
Correct Answer: Assess route across ceiling



2. An ______ is where a primary bonding bussbar (PBB) should be used -
Correct Answer: EF


3. If you terminate Category 6 cable onto Category 6A patch panels and use
Category 5e patch cords, the overall performance rating of the channel is? -
Correct Answer: Category 5e


4. When the labeling scheme is based upon the customer's requirements, it is
advisable to obtain the documentation in the form of a? - Correct
Answer: Cut sheet


5. When installing backbone cabling, labels should be within ________ of the
connecting hardware terminated to the cabling - Correct Answer:
305mm (12in)



6. The IEEE 802.11 standard relates to? - Correct Answer: Wireless LANs

,7. Two 90 degree bends are allowed in any one conduit segment, a third
bends may be acceptable under certain circumstances, the following are
acceptable:___________ - Correct Answer: Conduit is increased to the
next trade size, the conduit does not exceed 10m (33ft)



8. The copper cable category with its bandwidth limits: _________ -
Correct Answer: Cat 5-100Mhz, Cat 5e-100Mhz,Cat6- 250 Mhz, Cat6A-500
Mhz


9. When using cable management, care should be used to select management
that protects:_______ - Correct Answer: Minimum bend radius


10.When atmospheric testing a confined space prior to entering, the following
ranges indicate a safe oxygen level:_______ - Correct Answer: Between
19.5% and 23.5%


11.If the ICT installer is installing a fire stop assembly, the only way to properly
install the assembly would be per:_____ - Correct Answer:
Manufacturers directions


12.The two following models a re conductor splice connectors used for copper
cabling:______________ - Correct Answer: straight through and Butt



13.Modular connectors can generally accommodate:____________ -
Correct Answer: 22 to 28 AWG

,14.What are characteristics of insertion loss? - Correct Answer: Insertion
loss increases with temperature, frequency, and cable length


15.__________ has significant drawbacks with regard to distribution and is not
generally recommended as a horizontal cabling solution - Correct
Answer: The poke-thru method


16.When staggering cables in a pulling bundle, the recommended distance
between attachment points is:_________ - Correct Answer: 75mm (3in)


17.Which two options should be verified prior to the removal of abandoned
cable? - Correct Answer: The cabling does not support active circuits
and written permission from the owner to remove the cabling


18.When managing the inventory of materials and supplies on a job it is
important that a materials list contain at least two columns, The two
columns to be included are______ - Correct Answer: Materials
dispensed and materials received


19.The use of under carpet telecommunications cable should be limited to? -
Correct Answer: Locations unable to be cabled by other methods


20.What is the minimum amount of clearance between underfloor cable trays?
- Correct Answer: 150mm (6in)

, 21.What is the most common method of displaying a labeling scheme -
Correct Answer: Adhesive labels


22.What type of termination allows for the termination of an insulated
conductor without stripping the insulation - Correct Answer: IDC


23.When developing a job plan, the labeling scheme should be determined
by:________ - Correct Answer: Industry standards and customer
requirements


24.When installing a horizontal backbone cable, the service slack should be
long enought to reach __________ the pathway, plus floor to ceiling -
Correct Answer: The opposite side of the TR


25.In order to ensure the minimum performance of the cable channel, the
connecting hardware used for a horizontal cabling segment must be:______
- Correct Answer: At least the same or higher performance category
than that of the installed horizontal cable


26.These are troubleshooting tasks in the correct order from start to finish -
Correct Answer: 1.Verify the problem
2.Isolate the problem
3.Repair the problem
4.Test the problem


27.Inter building circuits are considered to have lightning exposure unless the
following conditions exist:______ - Correct Answer: The area has an

Document information

Uploaded on
August 1, 2026
Number of pages
54
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
283
Followers
87
Items
3344
Last sold
5 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions