ACE THE TEST
Type I (fire-resistive) - ANSWER ✔✔Type I construction provides the
highest level of protection from fire spread as well as structural collapse.
Reinforced concrete - ANSWER ✔✔A type of concrete that is
strengthened with steel reinforcement.
Precast concrete - ANSWER ✔✔Concrete elements that are cast and
cured in a controlled environment before being transported to the
construction site.
Protected steel - ANSWER ✔✔Steel that is treated to resist fire
damage.
,Type II (noncombustible) - ANSWER ✔✔Composed of materials that
will not contribute to fire development or spread.
Type III (ordinary construction) - ANSWER ✔✔Commonly found in
mercantile, business, and residential structures and older schools.
Void spaces - ANSWER ✔✔Spaces inside wooden channels that roof
and truss systems create between wall studs, which are less protected
than in type I and II construction.
Type IV (heavy timber) - ANSWER ✔✔Characterized by the use of
large-dimensioned lumber or laminated wood.
Glue-laminated beams - ANSWER ✔✔Beams made from layers of
wood glued together, which may fail when exposed to fire.
Type V (wood frame) - ANSWER ✔✔The exterior load-bearing walls
are composed entirely of wood.
Factory built homes - ANSWER ✔✔Structures that are partially or
completely built in a factory and shipped to the location on which they
are to be installed.
Manufactured (mobile) homes - ANSWER ✔✔The most common
type of factory built homes, almost completely prefabricated prior to
delivery and the least expensive.
, Modular homes - ANSWER ✔✔Modular or sectional homes must
comply with the same local building codes as site-built homes.
Panelized homes - ANSWER ✔✔Assembled on-site from pre-
constructed panels made of foam insulation sandwiched between sheets
of plywood.
Pre-cut homes - ANSWER ✔✔Homes that are pre-cut and
assembled on-site.
Fire walls - ANSWER ✔✔Provide separation to meet the
requirements of a specified fire-resistance rating.
Basements - ANSWER ✔✔Partially underground, fully underground,
or walk-out or 'daylight' structures.
Protected stairs - ANSWER ✔✔Are enclosed with fire-rated
construction, usually with either a 1 - 2 hour rating, depending on
building height.
Unprotected stairs - ANSWER ✔✔May serve as a flow path for fire
and smoke, they will not protect anyone using them from exposure to the
products of combustion.
COPYRIGHT©NINJANERD 2025/2026. YEAR PUBLISHED 2026. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE. PRIVACY
STATEMENT. ALL RIGHTS RESERVED
3