FSDNY S98 Exam REVIEW 2026/2027 QUESTIONS
WITH ANSWERS RATED A+
• The following are examples of line type detection except -✓✓ ionization smoke
detector

• He could tonight a circuit to which automatic or manual initiating devices are
connected where the signal received does not identify the device operated is called? -
✓✓ A signaling line circuit

• Secondary power supplies are required to have sufficient power to operate the fire
alarm system in a non alarm condition for _______ hours and then be capable of
operating all notification devices for a minimum of ______ minutes -✓✓ 24 hours and 5
minutes

• Secondary power supplies for emergency voice evacuation systems are required to
have sufficient power to operate the system in a non along condition for ______ hours
and kin be capable of operating the system during a fire or other emergency for a
minimum of ______ minutes -✓✓ 24 hours and 15 minutes under maximum load

• Secondary power supply shall automatically provide power to the protected premises
fire alarm system within _______ seconds when ever primary power fails to provide
minimum voltage required for proper operation? -✓✓ 10 seconds

• Cording to NFPA chapter 4, batteries shall be permanently marked with what
information? -✓✓ Month and year of manufacture

• NFPA 72 "record of completion" is prepared: -✓✓ upon completion of installation at
just acceptance test

• According to NFPA chapter 4, the control panel charging apparatus shall be taken full
of recharging batteries within _____ _____ after batteries have been fully discharged? -
✓✓ 24 hours

• According to the fire code of New York City, smoke detectors may be tested by the
following methods except for: -✓✓ Measured aerosol smoke introduced into the detector

• What type of drawing typically shows correct conductor counts? -✓✓ Riser diagrams

• According to the fire code and fire rules, who is responsible for preventing
unnecessary and unwanted alarms? -✓✓ Owner of a promise or a part thereof

, • I'll take you way and which according to NFPA chapter 4, a coded alarm signal shall
consist of not less than ______ complete rounds of the number transmitted. Each round
shall consist of not less than a ______ impulses -✓✓ 3 rounds and 3 impulses

• According to the fire rules, who is responsible for making in trees in the smoke
detector maintenance log? -✓✓ The fire safety director or a person designated by
building owners if no FSD

• According to NFPA chapter 4, installation Conductors shall be monitored for integrity.
The occurrence of a single open or single ground fault condition shall be automatically
indicated within ______ seconds -✓✓ 200 seconds

• All of the following are good conductors of electricity except -✓✓ carbon

• Which of the following is an example of an initiating device? -✓✓ Supervisory air
pressure switch and photo electric smoke detector

• Into voice along and initiating device which is destroyed as a result of its operation is
what type? -✓✓ Non restorable

• It's the face of the nobleman equipment you shall be designed so that it is capable of
performing its intended function at ______ of its name plate voltage -✓✓ 85%

• When installing heat detectors on ceilings, a row detector shall be located -✓✓ Within
3' of the peak

• The minimum distance for mounting of a spot type smoke detector from an air supply
diffuser is? -✓✓ 3' from diffusers

• This is regarding manual fire alarm boxes, NFPA 72 requires that they be
conspicuous, unobstructed, and ________ -✓✓ accessible

• Regarding manual fire alarm boxes, NFPA 72 requires that travel distance to the
nearest fire alarm Box shall not exceed -✓✓ 100 feet

• The maximum number of water flow switches permitted to be connected to a single
IDC shall not exceed -✓✓ 5

• Fire pumps shall be supervised for: (find the incorrect answer) -✓✓ Pump running -
supervisory signal

• to meet the requirements for distinctive signals, building evacuation signals shall be? -
✓✓ ANSI 53.41 Temporal 3 signal

Document information

Uploaded on
July 31, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PACKPASS
3.5
(6)
Sold
50
Followers
2
Items
7271
Last sold
3 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions