What is the resistance of the terminating resistor on networks equipped with one start connector? -
correct answer 60 ohms
With the bus active and no faults present, what voltages should be measured on can-c(+)? - correct
answer approximately 3.2v
What atlantis-high network uses splice block connectors? - correct answer can-bh
With the bus active and no faults present, what voltages should be measured on can-b(-)? - correct
answer approximately 0.4v
Which resource should be used first for troubleshooting drb iii emulator concerns? - correct answer
witech knowledge base
With the bus active and no faults present, what voltages should be measured on lin? - correct answer
7.0v-10.0v
What electrical architecture requires the use of the mopar diagnostic pod (mpd) for diagnostics? -
correct answer atlantis-high
Which of the following scan tool functions ate prevented if a security gateway (sgw) becomes locked?
Select all that apply. - correct answer start an actuator
Run a system test
Flash program a module
With the bus active and no faults present, what voltages should be measured on can-c(-)? - correct
answer approximately 1.8v