FLORIDA HOME INSPECTOR EXAM 900 QUESTIONS COMPLETE WITH 100% VERIFIED ANSWERS .Service entrace conductors run from the service drop to the service box or service panel. True or False? - ANSWERS-True .The service size is determined by the amperage and the voltage ratings of the service. - ANSWERS-True .Is the service drop overhead or underground? - ANSWERS-Overhead .Are service laterals overhead or underground? - ANSWERS-Underground .The drip loop is typically part of the service drop. True or False? - ANSWERS-False .The wire size for the service drop must be the same as the wire size for the service entrance conductors. True or False? - ANSWERS-False .How many wires would you typically find in a 240-volt service drop? - ANSWERS-3 .What would 4 wires mean? - ANSWERS-3-phase electricity .What would 2 wires usually mean? - ANSWERS-120 volt service .List 7 common problems with service drops. - ANSWERS-1. Overhead wires too low. 2. Damaged or frayed wires. 3. Trees or vines interfering with wires. 4. Wires too close to doors or windows. 5. Wires not well-secured to the house. 6. Poor connection between service drop and service entrance. 7. Inadequate clearance from roofs. .List clearances above ground, swimming pools, and roofs. - ANSWERS-above roadway--18 ft. above driveway--12 ft. above flat roof--8 to 10 ft. above sloped roof--18 inches away from water in swimming pool--22.5 ft 3 ft. above sloped roof with pitch 4 in 12 above walkway--10 ft. .The service entrance conductors run from the _________ to the ___________. - ANSWERS-service drop to service box .All service entrance conductors must be in conduit. True or False? - ANSWERS-False .All service entrance conductors must be attached above roof level. True or False? - ANSWERS-False .The drip loop should be as close to the roof as possible. True or False? - ANSWERS-False .List 10 common problems with service entrance conductors. - ANSWERS-1. No drip loop 2. No mast head 3. Mast head not weather tight. 4. Mast or conduit bent. 5. Mast or conduit rusted. 6. Mast rotted (if wood). 7. Mast conduit or cable not well secured. 8. Mast conduit or cable not weather tight. 9. Conduit or cable not well sealed at house/wall penetration. 10. Cable frayed, damaged, or covered by siding. .List 4 common areas of water penetration into service entrances. - ANSWERS-1. conduit joints 2. mast head 3. roof flashing 4. meter base 5. house entry .List 2 functions of the drip loop. - ANSWERS-1. Prevents water entry into the conduit or service entrance conductors. 2. Shows that the service drop wires are not straining the splices. .Roughly 999 out of 1000 houses have _________ volts available. - ANSWERS-240 .Roughly 999 out of 1000 houses have __________ service entrance wires. - ANSWERS-3 .Load calculations are part of a home inspection. - ANSWERS-False .Implications of an undersized service include: a. shock hazard b. fire hazard c. shock and fire hazard d. melting insulation e. nuisance tripping of the main fuses and breakers - ANSWERS-e. .What is the largest single-phase service that you are likely to find in a home? - ANSWERS-400 amps .What size copper wire would you expect to find on the service entrance for: a. 60-amp service b. 100-amp service c. 200-amp service - ANSWERS-a. 6 gauge b. 4 gauge c. 2-0 gauge .Which of the following is a reliable way to identify the service size? a. the size of the service drop wires

Content preview

FLORIDA HOME INSPECTOR EXAM 900
QUESTIONS COMPLETE WITH 100%
VERIFIED ANSWERS

\.Service entrace conductors run from the service drop to the service
box or service panel. True or False? - ANSWERS-True


\.The service size is determined by the amperage and the voltage
ratings of the service. - ANSWERS-True


\.Is the service drop overhead or underground? - ANSWERS-Overhead


\.Are service laterals overhead or underground? - ANSWERS-
Underground


\.The drip loop is typically part of the service drop. True or False? -
ANSWERS-False


\.The wire size for the service drop must be the same as the wire size
for the service entrance conductors. True or False? - ANSWERS-False

,\.How many wires would you typically find in a 240-volt service drop? -
ANSWERS-3


\.What would 4 wires mean? - ANSWERS-3-phase electricity


\.What would 2 wires usually mean? - ANSWERS-120 volt service


\.List 7 common problems with service drops. - ANSWERS-1. Overhead
wires too low.
2. Damaged or frayed wires.
3. Trees or vines interfering with wires.
4. Wires too close to doors or windows.
5. Wires not well-secured to the house.
6. Poor connection between service drop and service entrance.
7. Inadequate clearance from roofs.


\.List clearances above ground, swimming pools, and roofs. - ANSWERS-
above roadway--18 ft.
above driveway--12 ft.
above flat roof--8 to 10 ft.
above sloped roof--18 inches
away from water in swimming pool--22.5 ft

,3 ft. above sloped roof with pitch > 4 in 12
above walkway--10 ft.


\.The service entrance conductors run from the _________ to the
___________. - ANSWERS-service drop to service box


\.All service entrance conductors must be in conduit. True or False? -
ANSWERS-False


\.All service entrance conductors must be attached above roof level.
True or False? - ANSWERS-False


\.The drip loop should be as close to the roof as possible. True or False?
- ANSWERS-False


\.List 10 common problems with service entrance conductors. -
ANSWERS-1. No drip loop
2. No mast head
3. Mast head not weather tight.
4. Mast or conduit bent.
5. Mast or conduit rusted.
6. Mast rotted (if wood).

, 7. Mast conduit or cable not well secured.
8. Mast conduit or cable not weather tight.
9. Conduit or cable not well sealed at house/wall penetration.
10. Cable frayed, damaged, or covered by siding.


\.List 4 common areas of water penetration into service entrances. -
ANSWERS-1. conduit joints
2. mast head
3. roof flashing
4. meter base
5. house entry


\.List 2 functions of the drip loop. - ANSWERS-1. Prevents water entry
into the conduit or service entrance conductors.
2. Shows that the service drop wires are not straining the splices.


\.Roughly 999 out of 1000 houses have _________ volts available. -
ANSWERS-240


\.Roughly 999 out of 1000 houses have __________ service entrance
wires. - ANSWERS-3

Document information

Uploaded on
July 27, 2026
Number of pages
190
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
maingirose
4.3
(4)
Sold
28
Followers
0
Items
2072
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions