UDC was required at time of installation for all systems
January 1, 2000
installed after?
July 1, 2005, service techs shall possess or work under
someone who has a current certification indicating he or ICC UST Service Technician Exam
she has passed the?
ICC cert must be renewed every? 24 months
Service techs must possess or be employed by a person
The individual has a tank testing license
who has the appropriate contractor's license unless?
Tests UST monitoring equipment, trouble shoots UST sys-
Service tech is defined by any individual who?
tems, and/or installs UST monitoring equipment.
If the manufacturer training no longer exist, the local
Approve comparable alternate training .
agency may?
UST includes? Tank and connected piping
What is considered a UST? A petroleum underground storage tank.
What UST system meets the requirements for secondary
Doubled wall tanks
containment?
According to title 23; the following piping components if
installed after July 1, 1987 must have secondary contain- Pressured product piping
ment.
What is considered "pipe" on tanks installed after July 1, Pressured product piping and below ground vapor recov-
2003? ery.
Under dispenser containment (UDC) was required for all
December 31, 2003
existing UST systems by
What system is for exchanging gas vapors in a storage
Stage 1 vapor recovery
tank and product in a fuel delivery truck
Which approved method for non-visual monitoring for
Statistical Inventory Reconciliation (SIR)
existing UST systems.
, ICC California UST Service Technician Comprehensive Resource To Help You Ace 2026-2027 Exams
Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS
Guaranteed Pass First Attempt!! Current Update!!
ATG must be capable for detecting a release of? 0.2 gallons per hour
What is no longer an approved method for non-visual
Manual inventory reconciliation.
monitoring on existing UST systems?
Automatic line leak detectors installed on underground
piping with secondary containment shall be capable of 3 gallons per hour at 10 psi
detecting a leak of ?
How often should ATG be programmed to test the tank? At least monthly
According to PEI RP 300, a combustible gas can be used
Detect vapor leaks in a vapor recovery system.
to?
According to PEI RP 300, a written scope of work for vapor
Construction plans
recovery installation should include?
Positive shut ott overfill protection device must stop the
95% full
flow of fuel when the tank is no more then?
According to Executive Order (EO) VR 201-A , what could
Depended filter seal damage
cause a nozzle shut ott mechanism or malfunction?
According to VR 201-A, breakaway reconnection must be? Logged in GDF log
According to PEI RP 300 what is an INCORRECT method of Sketching a diagram on the inside cover of vapor recovery
documenting piping location? equipment manual
According to PEI RP 300 as built drawing or pictures of
the underground pipping and other components shall maintained as long as UST is in service.
be .
According to EO VR 101-E maintenance records are re-
Name and Designated UST Operator.
quired to include what?
The Phil-Tite EVR Phase 1 system require that vapor vent
Used with no more than 3 p/v valves
pipes at any UST system be
Nozzle dispensing shut ott test
, According to EO VR 2010 after installing a new spout
assembly in the Healy 900 nozzle the following test must
be conducted?
According to Healy EO VR 201-A a vapor recovery record
Gasoline dispensing facility operator(GDF)
is to be maintained by?
An enhanced leak detection test is required within how
1000 feet
many feet of a public drinking well?
What are the components of the Fire Triangle? Fuel, Heat/Ignition Source, Oxygen
If equipped with an over fill alarm, it must be located? So it can be seen or heard from the delivery location.
If installed, the following requires independent 3rd party
certification to prove compliance with established regula- Automatic Tank Gauge, Liquid Product Detectors, SIR
tions.
Where are ATG's installed? Opening in top of the tank
What is true about ATG's They're capable of alarming operator of low product level
Releases greater than 25 gallons that escape secondary
The following types of releases must be reported to the containment. Release that escape primary containment.
local agency. Releases less than 25 gallons which escape secondary
containment
If an unauthorized product release meets the require-
ments for reporting to the local agency, verbal notification
24 HRS, 5 DAYS
must be made within hours, followed by a written
notification within days.
The following unusual conditions shall be reported to the
Water in spill buckets
local agency, EXCEPT:
If the monitoring system detects a leak that has occurred, Unless the monitoring device is found to be defective and
the local agency must be notified unless . is immediately repaired.
Cause of release