LADWP Electric Station Operator
Exam – Los Angeles Department
of Water and Power –2026–2027
Edition




Exam Overview & Qualification Requirements

The Electric Station Operator (5224) position with the Los Angeles Department of
Water and Power involves operating high voltage electric and auxiliary equipment in
hydroelectric generating, receiving, and distributing stations. All entry-level
positions are temporary training positions requiring successful completion of an
intensive 24-month on-the-job training program.

Feature Details

Salary Range $72,119 - $137,286 annually

Training Period 24-month intensive OJT program

Work Schedule 24/7 operations, rotating shifts, holidays, weekends, on-call duty

Locations Los Angeles, Owens Valley, Castaic, Adelanto, Nevada

License Required Valid California Class C driver's license within 30 days of appointment

,SECTION 1: ELECTRICAL THEORY & FUNDAMENTALS

Question 1
An Electric Station Operator is monitoring a 34.5 kV bus and observes that the line-
to-line voltage has dropped to 31 kV. What is the approximate percentage voltage
drop from nominal?

A. 5.2%
B. 10.1%
C. 15.3%
D. 20.4%

Answer: B. 10.1%

Rationale: Percentage voltage drop = [(Nominal – Actual) / Nominal] × 100 = [(34.5
– 31) / 34.5] × 100 = (3..5) × 100 = 10.14% ≈ 10.1%. This exceeds typical
allowable voltage variations (±5%) and would require operator investigation and
possible corrective action. Option A miscalculates using 31 as the denominator.
Options C and D represent significantly larger deviations.




Question 2
In a three-phase AC system, the phase-to-phase voltage is 480 volts. What is the
approximate phase-to-neutral voltage?

A. 240 volts
B. 277 volts
C. 340 volts
D. 480 volts

,Answer: B. 277 volts

Rationale: In a wye-connected three-phase system, V_phase-to-neutral =
V_phase-to-phase / √3. Therefore, .732 = 277 volts. This relationship is
fundamental for operators when verifying metering and protection circuits. Option A
(240V) represents a single-phase 480/240 split-phase configuration. Option C
incorrectly uses a different multiplier. Option D confuses line and phase quantities.




Question 3
An operator measures zero-sequence current flowing through a transformer
neutral. This indicates:

A. Balanced three-phase loading
B. An unbalanced fault condition or ground fault
C. Normal capacitive charging current
D. Transformer core saturation

Answer: B. An unbalanced fault condition or ground fault

Rationale: Zero-sequence current (I₀) flows only during unbalanced conditions
involving ground. In a balanced three-phase system, the vector sum of phase
currents equals zero, and no neutral current flows. The presence of zero-sequence
current indicates a ground fault, unbalanced loading, or a line-to-ground condition.




Question 4
An Electric Station Operator is performing switching on a 230 kV circuit. Which
parameter is MOST critical to verify before opening a circuit breaker to de-energize
the line?

, A. Ambient temperature
B. Load current on the circuit
C. Humidity level
D. Time of day

Answer: B. Load current on the circuit

Rationale: Before opening a circuit breaker, the operator must verify that the load
current is within the breaker's interrupting rating and that the circuit can be safely
de-energized without overloading other equipment or causing customer outages.
Load current directly affects the arc energy and switching safety.




Question 5
In a substation, the potential transformer (PT) ratio is 2000:1. If the secondary
voltmeter reads 115 volts, what is the primary voltage?

A. 57.5 kV
B. 115 kV
C. 230 kV
D. 345 kV

Answer: C. 230 kV

Rationale: Primary voltage = Secondary voltage × PT ratio = 115 V × 2000 =
230,000 V = 230 kV. PTs step down high voltages to safe, measurable levels for
metering and protection relays. Accurate PT ratios are essential for correct
protection settings and metering.

Document information

Uploaded on
July 20, 2026
Number of pages
54
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$30.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
176
Followers
6
Items
2155
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions