SAFE PRACTICES FOR THE HOME INSPECTOR COURSE EXAM LATEST
2026 UPDATED QUESTIONS AND VERIFIED 100% SOLUTIONS
(2026/2027) |A+ GRADED |GUARANTEED PASS
When starting a combustion appliance, an inspector should allow gas to flow for no more than
_____ seconds before shutting down the flow of gas or the electrical system. - Answers -10
The safest and fastest method for shutting off a combustion appliance if the gas fails to ignite in
a timely manner at start-up is by using the __________. - Answers -kill switch
If a combustion appliance suffers dangerous pre-ignition or fails to ignite at start-up, the
inspector should ___________. - Answers -shut it down, tag it, and notify those involved in the
transaction
Pre-ignition happens when gas flowing into a combustion appliance ignites ___________. -
Answers -too late
T/F: An inspector should activate the reset button of an oil-fired combustion appliance no more
than twice. - Answers -false
T/F: In order to avoid problems with pre-ignition when starting a combustion appliance,
whenever possible, the inspector should shut off power to the appliance before turning up the
thermostat. - Answers -true
1|Page
, Multiple resetting of an oil-fired combustion appliance can result in __________. - Answers -a
burner fire
Class 00 electrical gloves are rated for _____ volts AC. - Answers -500
The proper screws for securing a dead front are _________. - Answers -fine-threaded and blunt
Before touching an electrical panel, an inspector should ____________. - Answers -test it with a
voltage detector to ensure that it is not energized
T/F: Some voltage detectors may not work properly if the user is not reasonably well-grounded.
- Answers -true
An inspector should insert nothing that is _______ into an electrical panel. - Answers -
conductive
Pushing wires aside to expose a panel rating label may cause ___________. - Answers -an
explosive short circuit
2|Page
2026 UPDATED QUESTIONS AND VERIFIED 100% SOLUTIONS
(2026/2027) |A+ GRADED |GUARANTEED PASS
When starting a combustion appliance, an inspector should allow gas to flow for no more than
_____ seconds before shutting down the flow of gas or the electrical system. - Answers -10
The safest and fastest method for shutting off a combustion appliance if the gas fails to ignite in
a timely manner at start-up is by using the __________. - Answers -kill switch
If a combustion appliance suffers dangerous pre-ignition or fails to ignite at start-up, the
inspector should ___________. - Answers -shut it down, tag it, and notify those involved in the
transaction
Pre-ignition happens when gas flowing into a combustion appliance ignites ___________. -
Answers -too late
T/F: An inspector should activate the reset button of an oil-fired combustion appliance no more
than twice. - Answers -false
T/F: In order to avoid problems with pre-ignition when starting a combustion appliance,
whenever possible, the inspector should shut off power to the appliance before turning up the
thermostat. - Answers -true
1|Page
, Multiple resetting of an oil-fired combustion appliance can result in __________. - Answers -a
burner fire
Class 00 electrical gloves are rated for _____ volts AC. - Answers -500
The proper screws for securing a dead front are _________. - Answers -fine-threaded and blunt
Before touching an electrical panel, an inspector should ____________. - Answers -test it with a
voltage detector to ensure that it is not energized
T/F: Some voltage detectors may not work properly if the user is not reasonably well-grounded.
- Answers -true
An inspector should insert nothing that is _______ into an electrical panel. - Answers -
conductive
Pushing wires aside to expose a panel rating label may cause ___________. - Answers -an
explosive short circuit
2|Page