NFPA 160 Flame Effects Operator Complete Study Questions with Verified Answers | Brand New Edition 1. Accumulator Charge Valve - ANSWER A valve used to control the flow of fuel into an accumulator 2. Approved - ANSWER Acceptable to the authority having jurisdiction. 3. Authority Having Jurisdiction (AHJ) - ANSWER The organization, office, or individual responsible for approving equipment, materials, an installation, or a procedure. 4. Effect Valve - ANSWER The last fuel shutoff valve before the flame effect burner. 5. Direct Ignition - ANSWER An automatic or manual ignition system that ignites fuel without a pilot. 6. Holding Area Rules - ANSWER Only enough fuel for one day may be stored in the holding area. It must be secured and supervised. ("The maximum quantity of flammable flame effect materials and loaded devices stored in a holding area shall be that quantity used in one day.") 7. Flame Effect Plan - ANSWER A plan for the use of flame effects. Must be approved by the AHJ. 8. Fail-Safe - ANSWER An attribute of a system where all parts of the system able to do harm are disconnected from all sources of power and stored energy at the primary disconnect point 9. Labeled - ANSWER Equipment and Materials must: 10. have a label, symbol or other identifying mark attached that is approved by the AHJ 11. have labels that state that periodic inspections have been done and passed showing compliance with appropriate standards 12. Listed - ANSWER Equipment, materials and services must be listed and acceptable to the AHJ. Must show that the equipment, materials and services have been tested and found suitable for the specified purpose. 13. Primary Safety Control - ANSWER A control with a sensor that is directly responsive to the ignition device attributes necessary for the safe operation of the effect. 14. Causes a safety shutdown in the event of ignition failure. 15. Proof-of-Closure Valve - ANSWER A safety shutoff valve equipped with an interlock switch that is actuated only when the valve is fully closed. 16. Proven Pilot - ANSWER A pilot flame supervised by a primary safety control is a 17. Safety Shutdown (Lockout) - ANSWER The safe shutdown of the flame effect in the event of the actuation of any flame effect primary safety control or limit switch. 18. Safety Shutoff Valve - ANSWER A listed, fast-closing valve that automatically and completely shuts off the fuel supply in response to a normal or safety shutdown. 19. Supervisory Cock - ANSWER A listed, manually actuated valve with two double-pole, double-throw switches that prove the valve position. 20. Vent Valve - ANSWER A listed, normally open, power-closed valve normally located between the two safety shutoff valves.

Content preview

NFPA 160 Flame Effects Operator
Complete Study Questions with
Verified Answers | Brand New
Edition

1. Accumulator Charge Valve - ANSWER A valve used to control the flow of
fuel into an accumulator


2. Approved - ANSWER Acceptable to the authority having jurisdiction.


3. Authority Having Jurisdiction (AHJ) - ANSWER The organization, office,
or individual responsible for approving equipment, materials, an installation,
or a procedure.


4. Effect Valve - ANSWER The last fuel shutoff valve before the flame effect
burner.


5. Direct Ignition - ANSWER An automatic or manual ignition system that
ignites fuel without a pilot.


6. Holding Area Rules - ANSWER Only enough fuel for one day may be
stored in the holding area. It must be secured and supervised.
("The maximum quantity of flammable flame effect materials and loaded
devices stored in a holding area shall be that quantity used in one day.")

,7. Flame Effect Plan - ANSWER A plan for the use of flame effects. Must be
approved by the AHJ.


8. Fail-Safe - ANSWER An attribute of a system where all parts of the system
able to do harm are disconnected from all sources of power and stored
energy at the primary disconnect point


9. Labeled - ANSWER Equipment and Materials must:


10.have a label, symbol or other identifying mark attached that is approved by
the AHJ


11.have labels that state that periodic inspections have been done and passed
showing compliance with appropriate standards


12.Listed - ANSWER Equipment, materials and services must be listed and
acceptable to the AHJ. Must show that the equipment, materials and services
have been tested and found suitable for the specified purpose.


13.Primary Safety Control - ANSWER A control with a sensor that is directly
responsive to the ignition device attributes necessary for the safe operation
of the effect.


14.Causes a safety shutdown in the event of ignition failure.


15.Proof-of-Closure Valve - ANSWER A safety shutoff valve equipped with
an interlock switch that is actuated only when the valve is fully closed.

, 16.Proven Pilot - ANSWER A pilot flame supervised by a primary safety
control is a


17.Safety Shutdown (Lockout) - ANSWER The safe shutdown of the flame
effect in the event of the actuation of any flame effect primary safety control
or limit switch.


18.Safety Shutoff Valve - ANSWER A listed, fast-closing valve that
automatically and completely shuts off the fuel supply in response to a
normal or safety shutdown.


19.Supervisory Cock - ANSWER A listed, manually actuated valve with two
double-pole, double-throw switches that prove the valve position.


20.Vent Valve - ANSWER A listed, normally open, power-closed valve
normally located between the two safety shutoff valves.


21.Holding Areas - ANSWER All flammable flame effect materials in
anticipation of use shall be stored in a holding area acceptable to the AHJ.


Content Requirements of Flame Effect Plan - ANSWER Name of Person, Group
or Organization responsible for the production


Dates and Times of the Production


Location of the Production


The Design Criteria in Appendix B

, Flame Effect Classification


Site Plan
MSDS


Documentation that combustible materials used have been rendered flame retardant


Name of the effect operator


Are requirements of what?


Site Plan Requirements - ANSWER A description of the flame effect


Location of flame effect devices and controls and control sequences


The area affected by the flame effect device


The location of the Audience


Fuels used and their estimated consumption


Air for combustion and ventilation for indoor effects


Flammable materials piping

Document information

Uploaded on
July 19, 2026
Number of pages
55
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
DrSammuel
5.0
(1)
Sold
7
Followers
0
Items
917
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions