CRT RRT NBRC UPDATED CORE REVIEW QUESTIONS
AND ANSWERS SURE A+
✔✔Positive Expiratory Pressure (PEP) Therapy - ✔✔-applying positive pressure using a
one-way inspiratory valve and a one-way expiratory resistor
-expiratory pressure from 10 - 20 cmH20 at mid-exhalation
-used for 15-20 mins 3-4x/day
-improve secretion expectoration, reduce RV (decrease hyperinflation) and improve
airway maintenance (CF, pneumonia)
-discontinue if sinusitis, epistaxis or ear infection occurs
-inspire larger than normal VT and exhale actively but NOT forcefully. exhalation 2-3x
longer than inspiration

✔✔Autogenic Drainage - ✔✔-primarily for CF and bronchiectasis
-breathe at low lung volumes to loosen secretions from the small airways
-helps to accumulate secretions in the middle airways
-during the last stage the patient breathes at high lung volumes

✔✔Intrapulmonary Percussive Ventilation - ✔✔-Combination of high frequency pulse
delivery (100-250 cycles/min of a sub-tidal colume and a dense aerosol
-percussive effect of gas delivery improves ventilation past obstructions in the airway
thereby delivering more aerosol to the distal airways.
-Dense aerosol delivery promotes bronchial hygiene, reduces edema, and relieves
bronchospasm with the appropriate medications
-starting source pressure is 30 psi

✔✔Discontinuing bronchial hygiene - ✔✔-clear breath sounds and x-ray
-ambulating well
-strong cough
-afebrile for 24 hours
-hazards occur (dizziness, SOB, cyanosis, etc.)

,✔✔iatrogenic hypoxemia - ✔✔induced by a physician's words or therapy (used
especially of a complication resulting from treatment)

can be caused by suctioning

✔✔Suction Pressures - ✔✔Adult: 100 - 120 mm Hg
Child: 80 - 100 mm Hg
Infant: 60 - 80 mm Hg

✔✔Coude tip catheter - ✔✔suction catheter angles to help suction the LEFT main stem
bronchus

✔✔Closed system/inline suction catheter (Ballard) - ✔✔-allows patient to recieve
ventilation and oxygenation during suctioning
-for pt with high oxygen/PEEP requirements, pulmonary infections, frequent suctioning
and hemodynamic instability

✔✔Catheter sizes - ✔✔-ideal length is 20 - 22 inches
-external diameter of the suction catheter should be no greater than 1/2 the inside
diameter of ET/trach tube

✔✔Lukens trap/sterile suction trap - ✔✔-collect sputum specimen
-placed in an upright position between the suction catheter and the suction tubing
-flush catheter with sterile water or isotonic saline
-saline for cytology samples

✔✔Change size and type of catheter if - ✔✔-difficulty removing secretions (verify
appropriate size for airway)
-change to Coude Catheter for LEFT main stem bronchus
-change to closed system if pt has an infection, PEEP, or frequent desaturation

✔✔Altering negative pressure - ✔✔-increase negative pressure to remove thick
tenacious secretions
-do not exceed appropriate pressures

✔✔Instill irrigating solutions - ✔✔-5-10 mL of normal saline to dilute secretions too thick
to aspirate
-5-10 mL of 10% solution of Acetylcysteine (Mucomyst) can be used for thick tenacious
secretions + bronchodilator

✔✔Troubleshooting Suctioning procedure - ✔✔-check catheter for patency
-assure vacuum is working/appropriate pressure
-change or empty a full collection bottle
-check all connections

, ✔✔Bubble humidiifier - ✔✔-incorporates pressure pop-pff valves set at 2 psig/40 mm
Hg
-check by occluding or pinching the connection tubing and listen for whistling sound
-if no sound = leak

✔✔Troubleshooting bubble humidifiers - ✔✔-efficiency depends of water level in the
reservoir = replace or refill if non disposable
-if whistling = flow too high or obstructed tubing

✔✔Passover or blow-by humidifer - ✔✔-evaporation occurs as gas passes over the
water container/reservoir
-least effective in humidifying an artificial airway unless heated
-commonly used in conjunction with infant ventilators and circuits

✔✔Heat Moisture Exchanger (HME) - ✔✔-should be located in the vent circuit between
the wye and the patient (where deadspace is located)
-creates a small VD
-can cause increased delivery pressure = replace HME
-removed during aerosol therapy
-not as effective as humidifiers and increase/thicken secretions = change to heated
humidifiers

✔✔Wick Humidifers - ✔✔-can deliver 100% body humidity (44mg/L)
-low risk of cross contamination (nosocomial infection) because no particles are being
produced
-for vents, CPAP, etc

✔✔Heated Wire Circuits - ✔✔-minimizes circuit condensation
-wire like structure inside the vent circuit to maintain a set gas temperature thru the
entire circuit
-can be both limbs or just inspiratory limb

✔✔Jet Nebulizers - ✔✔-utilize Bernoulli's principle to create an aerosol then encounter
a baffle
-creates particles within therapeutic size range (1-10 microns)

✔✔HHN/SVN - ✔✔-1 to 3 second breath hold is important to enhance medication
delivery
-sputtering sounds indicates that all of the solution has been nebulized

✔✔Large Volume Nebulizers - ✔✔-deliver bland aerosol to upper airway
-output: 1-2 mL/min
-heating element for thick secretions
-FiO2 decreased = air entrainment is increased. lower mist density, total flow or mist
output increases (vice-versa)

Document information

Uploaded on
July 19, 2026
Number of pages
22
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(40)
Sold
278
Followers
10
Items
32861
Last sold
3 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions