Distance the beam extends back onto the roof must be at
least (___) the distance it extends out from the fulcrum, but
for most construction scaffolds we use at least 2 times. -
ANSWERS-1.5 times
Window Wash davits should not be used for - ANSWERS-
Construction Scaffolds.
C-Hooks must maintain (_________) with the parapet or
cornice when they are properly rigged. - ANSWERS-3 points
of contact
C-Hooks and clamps should only be used on parapet that
are at least - ANSWERS-3 wythe of brick and have been
surveyed and approved by a PE or RA.
, C-Hooks must be - ANSWERS-load and seated prior to being
used
C-Hooks to be used for electric scaffolds must have a -
ANSWERS-solid or welded suspension eye.
Hooks used for rope scaffolds are not - ANSWERS-
interchangeable
Each tieback must be - ANSWERS-independent
Wire tiebacks must have - ANSWERS-three j-clips and a
thimble
Tiebacks must be secured straight back. If they are angled a
second tieback going the opposite direction must be
installed. - ANSWERS-Tiebacks must be secured straight
back. If they are angled a second tieback going the opposite
direction must be installed.
Tiebacks must be secured to structural members of the
building this includes (_______________________________)
and C-hooks should NOT be used. - ANSWERS-bulkheads,
ACTUAL QUESTIONS AND CORRECTLY
WELL DEFINED ANSWERS LATEST
ALREADY GRADED A+
Distance the beam extends back onto the roof must be at
least (___) the distance it extends out from the fulcrum, but
for most construction scaffolds we use at least 2 times. -
ANSWERS-1.5 times
Window Wash davits should not be used for - ANSWERS-
Construction Scaffolds.
C-Hooks must maintain (_________) with the parapet or
cornice when they are properly rigged. - ANSWERS-3 points
of contact
C-Hooks and clamps should only be used on parapet that
are at least - ANSWERS-3 wythe of brick and have been
surveyed and approved by a PE or RA.
, C-Hooks must be - ANSWERS-load and seated prior to being
used
C-Hooks to be used for electric scaffolds must have a -
ANSWERS-solid or welded suspension eye.
Hooks used for rope scaffolds are not - ANSWERS-
interchangeable
Each tieback must be - ANSWERS-independent
Wire tiebacks must have - ANSWERS-three j-clips and a
thimble
Tiebacks must be secured straight back. If they are angled a
second tieback going the opposite direction must be
installed. - ANSWERS-Tiebacks must be secured straight
back. If they are angled a second tieback going the opposite
direction must be installed.
Tiebacks must be secured to structural members of the
building this includes (_______________________________)
and C-hooks should NOT be used. - ANSWERS-bulkheads,