• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 10 pages
Exam (elaborations)

P-99 / Low PSI Oil Burner Operator Final Exam Questions and All Correct Answers.

Document preview thumbnail
Preview 2 out of 10 pages

All heating, combustion, and cooking equipment shall be provided with insulation or the building construction shall be fire protected, so that during operation the surface of combustible construction materials will not be raised to a temperature higher than ____. - Answer 170 ̊ F Acceptance tests: Boilers shall not be placed in operation upon completion of construction until they have been ____ and an equipment use permit has been issued by the commissioner. - Answer Inspected and tested. Periodic boiler inspections: All boilers shall be inspected at least ____ including chimney connections. - Answer Once a year. Owner's annual statement: The owner of each boiler that is subject to periodic inspections shall file an annual ____ with the commissioner, specifying the location of each boiler and arrangement for inspection. - Answer Written statement. What three things must be tested for any fuel burning and storage installation before the system can be operated? - Answer (1) Tightness of liquid fuel piping. (2) Tightness of fuel oil storage tanks. (3) Tightness of gas distribution piping. What are instruction cards for oil burning systems? - Answer Cards giving complete instructions for care and operation that are permanently located near the equipment. Every oil burning installation that is not fully automatic or requires preheating shall be operated by, or under, the direct supervision of a person holding a ____ issued by the fire commissioner. - Answer COF After any fuel burning equipment repair for which a licensed operator is required, such operator shall also check the repairs and be ____ while the equipment is started. - Answer Present. What is abatement of air contaminants? - Answer Compliance with the air pollution control code.

Content preview

P-99 / Low PSI Oil Burner Operator
Final Exam Questions and All Correct
Answers.
All heating, combustion, and cooking equipment shall be provided with insulation or the
building construction shall be fire protected, so that during operation the surface of
combustible construction materials will not be raised to a temperature higher than ____. -
Answer 170 ̊ F



Acceptance tests: Boilers shall not be placed in operation upon completion of construction until
they have been ____ and an equipment use permit has been issued by the commissioner. -
Answer Inspected and tested.



Periodic boiler inspections: All boilers shall be inspected at least ____ including chimney
connections. - Answer Once a year.



Owner's annual statement: The owner of each boiler that is subject to periodic inspections shall
file an annual ____ with the commissioner, specifying the location of each boiler and
arrangement for inspection. - Answer Written statement.



What three things must be tested for any fuel burning and storage installation before the
system can be operated? - Answer (1) Tightness of liquid fuel piping.



(2) Tightness of fuel oil storage tanks.



(3) Tightness of gas distribution piping.



What are instruction cards for oil burning systems? - Answer Cards giving complete
instructions for care and operation that are permanently located near the equipment.



Every oil burning installation that is not fully automatic or requires preheating shall be operated
by, or under, the direct supervision of a person holding a ____ issued by the fire commissioner. -
Answer COF



After any fuel burning equipment repair for which a licensed operator is required, such operator
shall also check the repairs and be ____ while the equipment is started. - Answer Present.



What is abatement of air contaminants? - Answer Compliance with the air pollution control
code.

, What are the 3 equipment classifications and their temperatures for the products of
combustion at the point of leaving the equipment? - Answer (1) Low Temp: 600° F or less.



(2) Medium Temp: 600° - 1000° F.



(3) High Temp: 1000° or greater.



Ventilation shall be capable of providing at least ____ CFM of air for each gallon of oil per hour
required to fire the equipment to gross output. - Answer 36



What is fuel-oil? - Answer Hydrocarbon oils with a flashpoint not lower than 100 F.
̊



The use of crankcase refuse oil as fuel-oil is ____. - Answer Prohibited.



Overflow pipes shall not be smaller in size than the ____ pipe. - Answer Supply.



Oil is heated in storage tanks by coils using which three possible methods? - Answer (1) Low
pressure hot water.



(2) Steam



(3) Electric heaters.



A remote control for oil burner is provided to stop what? - Answer The flow of oil to any
burner.



What are the four safety controls that shall be installed with each automatic burner? - Answer
(1) Oil temperature.



(2) Ignition.



(3) Stack or combustion.



(4) High temperature or pressure.

Document information

Uploaded on
July 5, 2026
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
COCOSOLUTIONS
4.1
(39)
Sold
232
Followers
16
Items
9649
Last sold
23 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions