2026 Exam Questions and
Answers | Already Graded A+
MFMD crews are recommended to conduct drills and physical training
how often - ANSWER ✔✔Daily
Company officers should ensure their crews receive how many hours of
drilling and training each set - ANSWER ✔✔4-10 hours
All crew related training activities must be entered where and how often -
ANSWER ✔✔Target solutions once each set of shifts
If a PFF ges to light duty, does it count towards their probation time -
ANSWER ✔✔No
,What needs to be done monthly with PFF - ANSWER ✔✔Progress
Report
PFF are not permitted to sign up for overtime on fire apparatus during
the first __ months of probation - ANSWER ✔✔6
PFF may only do time trades with other members from their recruit class
for the first __ months in the field - ANSWER ✔✔6
What is ROAM - ANSWER ✔✔Rule of Air Management
What states "know how much air is in your SCBA and manage that air so
that you can leave the IDLH before your low air warning alarm activates
- ANSWER ✔✔ROAM
What is considered "reserve air" for SCBA - ANSWER ✔✔Vibralert
What is the most overlooked aspect of air management - ANSWER
✔✔Beginning with less than a full bottle
What should be included in PCAN reports - ANSWER ✔✔Amount of
air supply
A technique where you take a short breath, hold, tackle a second short
breath before exhaling and then relax with a long exhale. Each breath
should take 5 seconds - ANSWER ✔✔Skip breathing
,What kind of SCBA does MFMD use - ANSWER ✔✔Scott Air-Pak x3
Snap-change
What is the inner shell of the SCBA made of - ANSWER
✔✔Aluminum Alloy wrapped with carbon fiber, fiberglass, and epoxy
resin
How long is the cylinder rated for - ANSWER ✔✔45 min
How many cubic ft of air does the cylinder contain - ANSWER ✔✔66
cu ft
How fetén must the SCBA bottle be tested - ANSWER ✔✔Every 5
years
What does the back frame mounted pressure reducer assembly reduces
the air pressure from the cylinder pressure down to? - ANSWER
✔✔110-160 psi
What goes off if the secondary pressure reducing path goes into effect -
ANSWER ✔✔Vibralert goes off
What side is the RIC UAC located on - ANSWER ✔✔Left side of the
pressure reducer assembly
What side is the EMSS located on - ANSWER ✔✔Right side wait belt
COPYRIGHT©NINJANERD 2025/2026. YEAR PUBLISHED 2026. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE. PRIVACY
STATEMENT. ALL RIGHTS RESERVED
3
, How many ft is the EBSS - ANSWER ✔✔3 ft
The regulator maintains a positive pressure during flows up to ___ LPM -
ANSWER ✔✔500 LPM
The demand valve for the regulator is activated by a diaphragm
responsive to what - ANSWER ✔✔The inhalation of the user
What side is the purge valve on the regulator - ANSWER ✔✔Left side
What side is the low pressure hose on - ANSWER ✔✔Left shoulder
strap
The low pressure hose has a quick disconnect coupling approximately
__" from the regulator - ANSWER ✔✔18 inches
EZ Flo II regulators have ___% less expiration resistance than EZ FLo -
ANSWER ✔✔25
What kind of face piece do we have - ANSWER ✔✔AV-3000 HT
How often must respirators be inspected - ANSWER ✔✔Start of each
shift and during cleaning after each use
To open the SBA cylinder, which way does the knob rotate -
ANSWER ✔✔Clockwise