A diphosphonate kit contian 180 mCi of Tc99m in 30 ml when it is prepared at
8am. Immediately, a 20 mCi dose is withdrawn for a bone scan. if the patient
arrives late at 9:30 and half the volume is accidentally discharged, how much
volume from the kit must now be added to the syringe to correct the dose to 20
mCi? (no other doses have been withdrawn meanwhile, and the decay factor for
1.5 hrs is 0.841)
a. 1.5 ml
b. 2.0 ml
c. 2.3 ml
d. 2.5 ml
e. 2.7 ml - SOLUTION-C. 2.3 mL
lots of math, sorry :(
a WBS bone scan film shows a good posterior image, but the anterior view
appears diffuse with greater soft tissue activity. what is the probable cause?
a. wrong collimator used for anterior
b. increased patient to detector distance on the ant relative to the post
c. low tagging efficiency of the RP
d. patient was not sufficiently hydrated
e. none of the above - SOLUTION-b. increased patient to detector distance on the
ant relative to the post
,Which of the following will not reduce the probability of contamination from
perspiration and saliva of a therapy patient?
a. disposable eating utensils
b. plastic covering over the mattress
c. covering the phone receiver with plastic
d. collecting the patient's waste and storing until decayed to background -
SOLUTION-d. collecting the patient's waste and storing until decayed to
background
bone marrow imaging is performed using:
a. MDP
b. HDP
c. sulfur colloid
d. Gd153
e. A and B - SOLUTION-C. sulfur colloid
why would an image of the brain be obtained during a lung perfusion scan using
Tc99m MAA?
a. rule out brain mets
b. to detect low tagging efficiency
c. to detect a R-L cardiac shunt
d. to see if pulmonary emboli have traveled into the cerebral arteries - SOLUTION-
c. to detect a R-L cardiac shunt
, all of the following have an effect on the concentration of eluate obtained from a
wet generator except:
a. time since last elution
b. volume of saline added to the charging port
c. size of collection vial
d. amount of Mo99 activity present on the alumina colum
e. both b and c - SOLUTION-b. volume of saline added to the charging port
a Mo/Tc generator has an elution efficiency of 89%. if 1.1 Ci of Tc is present on the
column, what is the estimated activity of eluate that will be obtained? a. 97.9 Ci
b. 979 mCi
c. 979 uCi
d. 97.9 mCi - SOLUTION-b. 979 mCi
Tc DPTA has be used for all of the following, EXCEPT:
a. aerosol lung scanning
b. renal flow study
c. brain flow study
d. shunt patency
e. spleen scanning - SOLUTION-E. spleen scanning
which of the following is not used as an anticoagulant?
a. heparin