FDNY COF P-98 EXAM QUESTIONS AND
CORRECT ANSWERS
Question 1

63.- Effects of Improper Operation of an Oil Burner System

Blockage in the chimney or flue passage

Correct Answer

Will cause the cellar or boiler room to become filled with smoke.



Question 2

105.- Discharge Pressure Requirements

The pressure required at the discharge of the pump will be the pressure

Correct Answer

Required at the point of use plus the friction losses in the intervening piping
with the installation of a back pressure regulating valve. Pressure and air
atomizing burners may require that relatively high pressure be provided by the
pump set if there is no pump on the burner itself. The valve should be sized so
that the pressure buildup (in the case of a back-pressure valve) or drop (in the
case of a pressure regulator) is small.




Page 1 of 99

,Question 3

5.- Supervision of Fuel-Oil Piping & Storage Operation

Shall be under the GENERAL SUPERVISION of P-98:

Correct Answer

A stationary fuel-oil storage tank, related piping, that is installed on the
lowest floor of the building and transfer fuel-oil through piping to another
stationary fuel-oil storage tank, or fuel burning equipment, installed above
such floor



Question 4
- Oil Burner Controls
The Steam pressure gauge...
Correct Answer

Shows the steam pressure inside the steam boiler. The pressure gauge reads in
psi (pounds per square inch). It is located on or near the top of the steam boiler.
Normal steam pressure for low pressure boilers does not exceed 15 psi. (If the
indicated stream pressure is significantly greater than the normal pressure, the
best action is to shut down the system and call 911 since this is a serious
problem)



Question 5

9.- Licences & Certificates

No oil burning equipment may operated until

Correct Answer

a) Certificate of Compliance has been issued by NYCDOB

b) Air pollution control code requirements NYCDEP

c) Permit for the Storage & use of fuel-oil issued by FDNY




Page 2 of 99

,Question 6

54.- Oil Burner Controls

The Gauge Glass

Correct Answer

Device used to indicate the water level of a steam boiler. It is the most
important control on the steam boiler. Gauge glass should have water visible
when the boiler is in operation.



Question 7

79.- Fuel Tanks, Piping & Valves

The Installation in accordance NYC Construction Codes

Correct Answer

The tank, piping and valves for appliances burning oil must be installed in
accordance with the requirements of the NYC Construction Codes. When oil
burning equipment is served by a tank which is above the level of the burner
inlet connection, and where the fuel supply line is taken from the top of the
tank, an approved anti-siphon valve or other siphon-breaking device must be
located at the highest point in the supply line.



Question 8

28.- Oil Burner Operation

Oil burners required approximately

Correct Answer

2000 cubic feet of air per gallon of oil consumed. The mixture of oil and air is
sprayed in vapor form into a firebox area (the combustion chamber) where
combustion takes place




Page 3 of 99

, Question 9
- Alarms
d) Some pumps are...
Correct Answer
Manually operated while others have intermittent operation. This does not
eliminate the requirement of shutdown interlocks and automatic back up
pump operation for safety purposes. Since each system is unique, the control
strategy will be different from one job to another.



Question 10

36.- Oil Burner Operation

Excessive Air Supply

Correct Answer

Can put out the flame



Question 11

105.- Emergency Vents

The normal and emergency vents are

Correct Answer

Required to be combined. For tanks installed above the lowest floor, such
combined vents must be piped, in an approved manner, into the vent or top of
the tank of the lowest floor storage tank that supplies fuel to the tank.



Question 12

6.- Supervision of Fuel-Oil Piping & Storage Operation Shall be under the PERSONAL
SUPERVISION of P-98 COF

Correct Answer

Periodic Inspection and Testing of tanks and piping




Page 4 of 99

Document information

Uploaded on
June 28, 2026
Number of pages
99
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorExpert
3.7
(81)
Sold
612
Followers
315
Items
11060
Last sold
15 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions