TFM 12 FIRE ALARM TECHNICAL
CERTIFICATION SCRIPT 2026 QUESTIONS
WITH SOLUTIONS GRADED A+

• Does a fire hood system and a kitchen need to be monitored by the fire
alarm system?.
Answer: Yes
• What does P.L.F.A stand for?.
Answer: Power Limited Fire Alarm
• Does a fire hood system and a kitchen need to be monitored by the fire
alarm system?.
Answer: Yes
• What does P.L.F.A stand for?.
Answer: Power Limited Fire Alarm
• What does N.P.L.F.A stand for?.
Answer: Non-Power Limited Fire Alarm
• What does N.P.L.F.A stand for?.
Answer: Non-Power Limited Fire Alarm
• What is the difference between NPLFA and PLFA? a P.L.F.A has the
voltage and power limited by a listed power source..
Answer: an N.P.L.F.A can operate at up to 600v, and the power output isn't
limited
• What material must NPLFA circuit conductors be made from?.
Answer: ONLY solid stranded copper is permitted.
• What is the difference between P.F.L.A and N.P.F.L.A? a P.L.F.A has the
voltage and power limited by a listed power source..
Answer: an N.P.L.F.A can operate at up to 600v, and the power output isn't
limited

,• What does A.W.G stand for?.
Answer: American Wire Gauge
• What material must N.P.F.L.A circuit conductors be made from?.
Answer: ONLY solid stranded copper is permitted.
• What does A.W.G stand for?.
Answer: American Wire Gauge
• What size conductors are permitted?.
Answer: Size 18 A.W.G and 16 A.W.G are permitted, provided they do not
exceed certain capacities.
• What is used to protect transformers or other devices supplied from
power-supply conductors?.
Answer: An over-current device not rated over 20 amperes.
• When located within 7 feet of the floor, how shall cables be fastened?.
Answer: Cables shall be fastened in an approved manner at intervals of not
more than 18 inches.
• What size conductors are permitted?.
Answer: Size 18 A.W.G and 16 A.W.G are permitted, provided they do not
exceed certain capacities.
• Single conductors shall not be smaller than ___ A.W.G?.
Answer: 18
• Conductors of 26 A.W.G shall only be permitted in which circumstance?.
Answer: Spliced with a connector listed as suitable for 26 to 24 A.W.G
• How shall PLFA conductors NOT be installed?.
Answer: PLFA conductors shall not be strapped, taped, or attached to the
exterior of any conduit or raceway.
• What is used to protect transformers or other devices supplied from
power-supply conductors?.
Answer: An over-current device not rated over 20 amperes.

, • What is Plenum cable?.
Answer: Cable that can be installed in ducts, plenums, or other spaces used
for environmental air.
• What is a Riser cable? It is capable of preventing fire from rising from floor
to floor..
Answer: Cable to be used in vertical wire runs in shafts between floors. Not
to be used where Plenum cable is required.
• When located within 7 feet of the floor, how shall cables be fastened?.
Answer: Cables shall be fastened in an approved manner at intervals of not
more than 18 inches.
• What is general purpose cable? It is resistant to the spread of fire..
Answer: Cable for general purpose fire alarm use. Not to be used where
plenum cable or riser cable is required.
• Why 'type' shall plenum cable be? What substitutions are allowed?.
Answer: Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be
substituted.
• Why 'type' shall riser cable be? What substitutions are allowed? C.M.R can
be substituted..
Answer: Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P.
• What 'type' shall general purpose wire be? What substitutions are permitted?
CM can be substituted (all types).
Answer: Power Limited Fire Alarm (F.P.L) C.M.P, F.P.L.P, C.M.R,
F.P.L.R, C.M.G
• What is the maximum voltage permitted through multi-conductor N.P.F.L.A
cables?.
Answer: 150 volts
• Single conductors shall not be smaller than ___ A.W.G?.
Answer: 18
• What is the voltage rating marked on P.F.L.A cables?.

Documentinformatie

Geüpload op
16 juni 2026
Aantal pagina's
22
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$13.99

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
FocusFile7
4.0
(26)
Verkocht
260
Volgers
4
Items
69456
Laatst verkocht
2 uur geleden



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen