answers 2026

1. Type ____ is multiconductor cable identified for use as underground service

entrance cable.: Type USE cable

2. Knife switch rated for more than 1200 Amps at 250Volts or less: Can be used only

as isolating switch, shall not be opened under load

3. Track lighting with outlets in a bathroom is not allowed because ?: Track lighting

has receptacle

4. Where internal combustion engines are used as the prime motor, an on site

fuel supply shall be provided with an on premise fuel supply sufficient for not

less than ____ hours full demand operation of the system: 6 hours

5. Fixed in place X-ray equipment properly supplied by a branch circuit rated

at not over ____ amperes shall be permitted to be supplied through a suitable

attachment plug cap and hard service cable cord.: 30 Amps

6. Where skin effect exist the ferromagnetic envelope shall be bonded at

____.: Both ends

7. GFCI protection at a carnival is not required for equipment at circuit if the

receptacle is of the ____type.: Locking

8. The maximum voltage drop from service point to the last over-current device

in a dwelling unit?: 4%

9. Which of the following statements best describe the grounding requirement

for central vacuum outlet: Accessible non current carrying metal parts are required to be connected to

an equipment grounding conductor.

10. In healthcare facilities, patient bed receptacles located in general care

areas shall be supplied by at least two branch circuits, which ____permitted to

originate from two separate transfer switches on the emergency system: Are

permitted

,11. Patient care areas of healthcare facilities ____ areas such as business offices,

corridors, lounges ,day rooms, or similar areas: Do not include

12. The patient care area is any portion of the healthcare facility where patients

are intended to be ____or ____.: Examined or treated

13. Each general care area patient bed location in a healthcare facility must be

provided with four ____ or ____ duplex receptacles: Single or two



NYC MASTER ELECTRICIAN EXAM



14. A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care
on a 24 hour basis of ____ or more patients: Four

15. Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal
raceways shall not be required and metal raceway

can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment: Listed fitting

16. Feeder and branch circuit conductors within ____ inches of a Ballast shall

have an insulation temperature rating not lower than 90°C (194°F) unless

supplying a luminaiere marked as suitable for a different insulation temperature: 3 inches

17. Manufactured wiring systems constructed with type MC cable shall be

supported and secured at intervals not exceeding ____ ft.: 6 ft

18. Where a main bonding jumper or a system bonding jumper is a screw only

the screw shall be identified with a ____ that shall be visible with the screw

installed: Green finish

19. Plug fuses a 15 amperes and lower rating shall be identified by a ____

configuration of the window, cap, or other prominent part to distinguish them

from fuses of higher ampere rating: Hexagon

20. The load for household electric clothes dryer's in a dwelling unit(s) shall be

either ____ watts (volt-amperes) or the nameplate rating, which ever is larger,

for each dryer served ?: 5000 watts

21. Service conductors installed as unjacketed multiconductor cable shall have

, a minimum clearance of ____ windows that are designed to be opened, doors,

porches, stairs fire escape or similar locations.: 3 ft (36 inches)

22. —— Cartridge fuses of the renewable type shall be permitted to be used

only for replacement in existing installation is where there is no evidence of

over-fusing or tampering.: Class H

23. Branch circuit conductors within ____inches of the ballast shall have an

insulation temperature rating not lower it 90°C 194°F: 3" inches

24. The minimum radius of a field bend on trade size 1 "1/4 RMC is ____.: 8

25. In a dwelling unit which appliance is allowed to have a 24"inch cord with

Attachment ground plug ?: Combination range hood/microwave oven



NYC MASTER ELECTRICIAN EXAM



26. Type 3 Surge Protective devices can be installed on the load side of a branch

circuit overcurrent device up to the equipment served.if ____ the type 3 SPD

connection must be a minimum 30'ft of conductor a distance from the service

or separately derived system disconnect: Included in the manufactures instructions

27. Which flexible cable is Allowed to be used for electric vehicle charging

station 300 Volts ?: EVJ

28. Type ____ fuse adapters shall be designed so that once inserted in a fuse

holder that cannot be removed: Type S fuse

29. Service drops Installed over roof shall have a vertical clearance of ____

above the roof surface, and unless a lesser distance is permitted by and

exceptions: 8'ft

30. Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway,

cable, or similar fittings with conductors of Class 1 or electric light or power

conductors, unless ____.: Separated by barrier

31. In the critical care areas of health care centers, each patient bed shall be

provided with a minimum of ____ duplex receptacles: 3 duplex (6 single)

Document information

Uploaded on
June 14, 2026
Number of pages
24
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Enursingtests
5.0
(1)
Sold
7
Followers
1
Items
1362
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions