1|Page
Fresenius Final Exam Newest 2026/2027 || Most
Recent Exam Actual Complete Real Verified Exam
Questions And Correct Answers (Verified Answers)
Already Graded A+ | Guaranteed Success!! Just
Released!!!
Hazardous Material Identification System HMIS labels are
required on all hazardous materials, including individual
bicarbonate containers: true or false - Answer-true
The first bleach solution used to clean a large blood spill
area (greater than 10mL/s) is? - Answer-1:10 - 1 parts
bleach and 9 parts water solution.
The main route of transmission of Hepatitis B in
Hemodialysis facilities is by exposure to infected
_________ and ________ - Answer-blood and bodily
fluids
When caring for a patient who is Hepatitis B positive, after
disconnecting the bloodlines, the technician MUST
perform which 3 actions before documenting? - Answer-
Remove gloves, sanitize hands, and put on a fresh pair of
gloves.
,2|Page
According to the CDC, patients who are hepatitis B
surface antigen (HBsAg) positive should be dialyzed in a
_________ area of the dialysis center, on a ___________
machine. - Answer-separate and dedicated
How long do you need to wash your hands with soap and
water? - Answer-40-60 seconds
How long do you need to sanitize your hands? - Answer-
20-30 seconds
The number one cause of chronic renal failure: - Answer-
Diabetes
When going from a dirty area to retrieve supplies in a
clean area, staff are required to complete: - Answer-hand
hygiene and put on new gloves
What must the dialysis technician do prior to leaving the
patient at the dialysis station to get clean supplies? -
Answer-Remove gloves, wash/ sanitize hands, and
retrieve items.
, 3|Page
You must wear a full- face shield, or mask with goggles,
when in an area with risk of: - Answer-blood splatter
Use of a diasafe filter allows the production of: - Answer-
Ultra pure dialysate
The dialysis technician has performed a rinse back on a
patient and failed to gather all the supplies needed to
disconnect the patient. What 2 things must the dialysis
technician do prior to getting clean supplies? - Answer-
Remove gloves and wash/ sanitize hands
Normal ________ is used to rinse and prime the tubing of
the extra corporeal circuit to remove sterilant and air. -
Answer-Saline
Air is removed from the extra corporeal circuit before
initiating treatment because it may cause _________
when trapped in the dialyzer. - Answer-Clotting
The most likely cause of contamination of the extra
corporeal circuit are _________ in the prime bucket with
__________ end caps. - Answer-Blood lines and open
Fresenius Final Exam Newest 2026/2027 || Most
Recent Exam Actual Complete Real Verified Exam
Questions And Correct Answers (Verified Answers)
Already Graded A+ | Guaranteed Success!! Just
Released!!!
Hazardous Material Identification System HMIS labels are
required on all hazardous materials, including individual
bicarbonate containers: true or false - Answer-true
The first bleach solution used to clean a large blood spill
area (greater than 10mL/s) is? - Answer-1:10 - 1 parts
bleach and 9 parts water solution.
The main route of transmission of Hepatitis B in
Hemodialysis facilities is by exposure to infected
_________ and ________ - Answer-blood and bodily
fluids
When caring for a patient who is Hepatitis B positive, after
disconnecting the bloodlines, the technician MUST
perform which 3 actions before documenting? - Answer-
Remove gloves, sanitize hands, and put on a fresh pair of
gloves.
,2|Page
According to the CDC, patients who are hepatitis B
surface antigen (HBsAg) positive should be dialyzed in a
_________ area of the dialysis center, on a ___________
machine. - Answer-separate and dedicated
How long do you need to wash your hands with soap and
water? - Answer-40-60 seconds
How long do you need to sanitize your hands? - Answer-
20-30 seconds
The number one cause of chronic renal failure: - Answer-
Diabetes
When going from a dirty area to retrieve supplies in a
clean area, staff are required to complete: - Answer-hand
hygiene and put on new gloves
What must the dialysis technician do prior to leaving the
patient at the dialysis station to get clean supplies? -
Answer-Remove gloves, wash/ sanitize hands, and
retrieve items.
, 3|Page
You must wear a full- face shield, or mask with goggles,
when in an area with risk of: - Answer-blood splatter
Use of a diasafe filter allows the production of: - Answer-
Ultra pure dialysate
The dialysis technician has performed a rinse back on a
patient and failed to gather all the supplies needed to
disconnect the patient. What 2 things must the dialysis
technician do prior to getting clean supplies? - Answer-
Remove gloves and wash/ sanitize hands
Normal ________ is used to rinse and prime the tubing of
the extra corporeal circuit to remove sterilant and air. -
Answer-Saline
Air is removed from the extra corporeal circuit before
initiating treatment because it may cause _________
when trapped in the dialyzer. - Answer-Clotting
The most likely cause of contamination of the extra
corporeal circuit are _________ in the prime bucket with
__________ end caps. - Answer-Blood lines and open