Practice Questions & Study Guide
Comprehensive exam preparation resource for the Maine Plumber
Journeyman-in-Training (JIT) licensing exam. Includes practice
questions, answer explanations, plumbing code review, safety standards,
water supply and drainage systems, venting requirements, and key
concepts to help candidates prepare for certification and career
advancement in the plumbing trade.
Question 1: Under the Maine Plumbing Examining Board rules, what is the maximum
duration that a Journeyman-in-Training plumber license can be held before it must be
converted to a full Journeyman license, assuming no extensions are granted?
A) 1 year
B) 2 years
C) 4 years
D) 5 years
Answer: C) 4 years
Rationale: According to Maine Plumbing Board statutes, a Journeyman-in-Training
license is intended to be a transitional authorization. It is issued for a maximum period
of up to 4 years to allow the individual to gain the required hours of field experience
under a Master Plumber.
Question 2: Which state entity has the final statutory authority to adopt, amend, and
enforce the Maine State Internal Plumbing Code?
A) The Department of Health and Human Services (DHHS)
B) The Maine Plumbing Examining Board
C) The Office of State Fire Marshal
D) The Department of Environmental Protection (DEP)
Answer: B) The Maine Plumbing Examining Board
Rationale: The Maine Plumbing Examining Board is legally tasked with overseeing
licensing qualifications, conducting disciplinary hearings, and officially establishing the
internal plumbing code standards for all public and private structures in Maine.
,Question 3: When executing a DWV (Drain, Waste, and Vent) rough-in water test
under the Maine State Internal Plumbing Code, what is the minimum required vertical
height of the water column above the highest point being tested?
A) 5 feet
B) 10 feet
C) 12 feet
D) 15 feet
Answer: B) 10 feet
Rationale: To ensure adequate hydrostatic pressure is applied throughout the system to
reveal potential structural leaks or joint failures, the code mandates a minimum water
column section of 10 feet, except for the topmost 10 feet of the vertical stack system.
Question 4: According to Maine Subsurface Wastewater Disposal Rules, what is the
absolute minimum horizontal separation distance required between a private potable
water supply well and a septic tank?
A) 50 feet
B) 60 feet
C) 75 feet
D) 100 feet
Answer: C) 75 feet
Rationale: Maine rules enforce strict setback distances to minimize the risk of biological
or chemical cross-contamination. A septic tank must remain at least 75 feet away from a
private well, whereas the disposal field itself requires a larger 100-foot buffer.
Question 5: Under Maine's internal plumbing standards, what is the maximum
allowable lead content by weight for pipes, pipe fittings, and plumbing fixtures utilized to
convey water intended for human consumption?
A) 0.2%
B) 0.25%
C) 2.0%
D) 8.0%
Answer: B) 0.25%
Rationale: Aligning with federal Safe Drinking Water Act updates adopted into Maine
law, any plumbing component contacting water intended for drinking or cooking must be
"lead-free," legally defined as containing a weighted average of not more than 0.25%
lead.
Question 6: What is the minimum required size of a building drain or building sewer
pipe serving a water closet under the Uniform Plumbing Code guidelines utilized in
Maine?
A) 2 inches
B) 3 inches
,C) 4 inches
D) 5 inches
Answer: B) 3 inches
Rationale: Code parameters stipulate that no drain line receiving the discharge of a
standard water closet may be smaller than 3 inches in nominal interior diameter to
reliably prevent blockages and handle sudden fixture unit loads.
Question 7: In Maine, when a Journeyman-in-Training is performing complex
installations on a job site, what structural supervision requirement must be met under
state licensing laws?
A) They may work completely alone if they have completed 1,000 hours of schooling.
B) They must be under the direct, on-site supervision of a licensed Master or
Journeyman plumber.
C) They must be supervised by a Master Plumber via telecommunication checks once
per day.
D) They can only work if an architectural engineer is present on the construction zone.
Answer: B) They must be under the direct, on-site supervision of a licensed
Master or Journeyman plumber.
Rationale: A Journeyman-in-Training is an apprentice-level designation in Maine. To
ensure public safety and code compliance, they cannot perform independent
installations and must be accompanied on-site by a fully licensed Journeyman or Master
Plumber.
Question 8: When installing a horizontal drainage pipe with a diameter of 2-1/2 inches
or smaller, what is the minimum required slope per foot under standard Maine plumbing
code regulations?
A) 1/16 inch per foot
B) 1/8 inch per foot
C) 1/4 inch per foot
D) 1/2 inch per foot
Answer: C) 1/4 inch per foot
Rationale: For drainage lines 2-1/2 inches or smaller, a minimum downward slope of 1/4
inch per foot is required to maintain adequate flow velocity, which allows liquids to carry
suspended solid wastes efficiently through the pipe.
Question 9: Under the Maine State Internal Plumbing Code, which type of device is
explicitly mandatory to install on a residential water service connection to prevent
contaminated water from siphoning back into the public water supply system?
A) A gate valve
B) A pressure-reducing valve
C) A backflow preventer
D) A water meter yoke
, Answer: C) A backflow preventer
Rationale: Backflow prevention assemblies protect public health by mechanically
stopping the reverse flow of non-potable liquids, solids, or gases into the clean public
distribution system caused by backpressure or backsiphonage.
Question 10: According to the core sizing tables in the plumbing code, what is the
assigned Fixture Unit (DFU) value for a standard residential automatic clothes washer?
A) 1 DFU
B) 2 DFUs
C) 3 DFUs
D) 4 DFUs
Answer: C) 3 DFUs
Rationale: Standard sizing conventions classify a domestic automatic washing machine
drainage discharge load as 3 Drainage Fixture Units, which mandates a minimum 2-
inch trap size to safely receive sudden high-volume pumping cycles.
Question 11: What is the maximum distance allowed between a plumbing fixture trap
and its qualifying vent connection for a 1-1/2 inch trap under the Uniform Plumbing
Code as applied in Maine?
A) 3 feet 6 inches
B) 5 feet
C) 6 feet
D) 8 feet
Answer: C) 6 feet
Rationale: To prevent the siphonage of a trap seal due to negative pressure fluctuations
in the drainage system, the maximum horizontal developed length from a 1-1/2 inch trap
to its vent connector is fixed at 6 feet.
Question 12: Under Maine state rules, what type of joint is explicitly prohibited for use
within a building's internal drainage or vent system?
A) Solvent-welded PVC joints
B) Threaded iron joints
C) Mastic or bitumen-wrapped joints
D) Solder joints on copper DWV lines
Answer: C) Mastic or bitumen-wrapped joints
Rationale: Only approved mechanical, chemical solvent-welded, or threaded
connections that maintain complete gas-tight and water-tight seals under pressure are
permitted. Wrapping joints in non-rigid adhesive sealants is strictly prohibited.
Question 13: When executing an air test on an internal plumbing drainage system in
Maine, what is the minimum test pressure that must be maintained for at least 15
minutes?