Practice Exam – Study Guide & Practice Questions 2026
Comprehensive exam preparation resource for the California Alarm Company Qualified
Manager licensing exam. Covers alarm system installation, intrusion detection systems, fire
alarm fundamentals, access control, CCTV and surveillance systems, electrical principles,
California regulations, safety standards, code compliance, troubleshooting, and business
management practices. Includes practice questions and answer explanations to help candidates
prepare for licensure and professional success in the alarm and security industry.
Question 1
An alarm company operator decides to hire a manager who holds an active Alarm
Company Qualified Manager (ACQM) certificate. Under the BSIS Alarm Company Act,
how many different licensed alarm companies can a single Qualified Manager actively
manage at the same time?
• A) Only 1 license entity at a time
• B) Up to 2 license entities, provided both physical locations are within 50 miles of
each other
• C) Up to 5 license entities, provided the manager owns at least a 10% share in
each firm
• D) Unlimited, as long as all entities operate within the state of California
Answer: A) Only 1 license entity at a time
Rationale: Under California Business and Professions Code, a Qualified Manager may
qualify only one alarm company operator license at any given time. They must be
actively in control of daily operational and administrative compliance for that specific
licensee entity.
Question 2
According to NFPA 72 regulations governing commercial fire alarm systems, what is the
mandatory mounting height window for a remote alphanumeric fire annunciator panel,
measured from the finished floor to the center of the display screen?
• A) Not less than 36 inches and not more than 48 inches
, • B) Not less than 42 inches and not more than 60 inches
• C) Exactly 60 inches from the floor base plane
• D) Not more than 66 inches (5.5 feet) above the floor plane
Answer: D) Not more than 66 inches (5.5 feet) above the floor plane
Rationale: NFPA 72 outlines that control equipment, remote annunciators, and user
interfaces must be installed so that the operational interface buttons and viewing
screens do not exceed 66 inches above the finished floor to ensure accessible view and
reach profiles.
Question 3
When running Class 2 low-voltage alarm wiring parallel to high-voltage electric light or
power lines inside an open commercial ceiling, what is the minimum physical separation
distance required if the wires are not enclosed in a conduit or raceway?
• A) 2 inches
• B) 4 inches
• C) 6 inches
• D) 12 inches
Answer: C) 6 inches
Rationale: The National Electrical Code (NEC Article 725) dictates that non-shielded
Class 2 low-voltage signaling circuits running parallel to open high-voltage power lines
must maintain a minimum physical clearance separation of 6 inches to minimize the risk
of high-voltage induction or accidental direct cross-contact fields.
Question 4
If an installation team must trace out a series loop containing four separate glass-break
sensors wired in a single series layout, and each sensor possesses an internal
resistance of 15 Ohms, what is the total circuit loop resistance before adding the end-of-
line resistor?
• A) 3.75 Ohms
• B) 15 Ohms
• C) 30 Ohms
• D) 60 Ohms
Answer: D) 60 Ohms
Rationale: In a series circuit layout configuration, internal resistance values directly
accumulate together along the continuous copper path. The calculation is: 15 Ohms +
15 Ohms + 15 Ohms + 15 Ohms = 60 Ohms.
,Question 5
Under the California Home Solicitation Sales Act, if a residential consumer legally
exercises their 3-day right to cancel, the alarm company must return any equipment left
on site, and the consumer is responsible for making that equipment available for pickup
at their property for how many days?
• A) 10 days
• B) 20 days
• C) 30 days
• D) 90 days
Answer: B) 20 days
Rationale: California Civil Code mandates that upon cancellation of a home solicitation
contract, the consumer must make any goods delivered under the contract available to
the seller in substantially as good condition as when received. If the seller fails to
demand possession of them within 20 days after cancellation, the goods become the
property of the consumer without further obligation.
Question 6
According to NFPA 72 life safety codes, if a commercial facility uses an air duct smoke
detector to automatically shut down HVAC fans during a fire event, the detector must
signal what type of condition at the primary Fire Alarm Control Panel (FACP)?
• A) Fire Alarm signal
• B) Trouble signal
• C) Supervisory signal
• D) Auxiliary notification bypass
Answer: C) Supervisory signal
Rationale: NFPA 72 requires duct smoke detectors to initiate a supervisory signal rather
than a primary building-wide evacuation fire alarm. This informs facility managers and
technicians that an HVAC isolation event has occurred without accidentally causing a
false building-wide panic.
Question 7
An alarm agent registration applicant has submitted their Live Scan fingerprints to the
state. Under BSIS rules, the applicant is legally permitted to perform field installation
and service work under a temporary status while awaiting final approval for a maximum
window of:
• A) 30 days
• B) 90 days
• C) 120 days
, • D) Zero days; they cannot perform any field agent duties until their registration is
fully approved and issued by the BSIS
Answer: D) Zero days; they cannot perform any field agent duties until their
registration is fully approved and issued by the BSIS
Rationale: California Business and Professions Code mandates that no individual can
perform the duties of an alarm agent or carry out field installation/service work until they
have successfully cleared the state background check and hold a valid, current
registration card issued on the BSIS registry.
Question 8
What electronic camera lens component physically opens or closes to control the
precise volume of light passing through the lens elements to strike the digital imaging
image sensor?
• A) Focal aperture or iris
• B) Aspect shutter
• C) Focal length varifocal pin
• D) Spatial lux filter
Answer: A) Focal aperture or iris
Rationale: The iris is an adjustable mechanical aperture that controls the diameter of the
lens opening. Expanding the iris allows more light into the camera during dark hours,
while constricting it prevents image overexposure during bright sunlight windows.
Question 9
According to the National Electrical Code, if a low-voltage Class 2 alarm power wire
passes through a hole drilled through a structural metal stud framing wall, what
protection accessory must be installed?
• A) Liquid polymer electrical tape wrap
• B) A non-conductive, listed plastic bushing or grommet inserted into the metal
hole
• C) A grounded copper grounding shield strap
• D) An intumescent foam caulk block packing
Answer: B) A non-conductive, listed plastic bushing or grommet inserted into the
metal hole
Rationale: To prevent structural building movements or vibrations from causing sharp
metal stud edges to slowly cut through low-voltage insulation jackets—creating short
circuits or ground faults—the NEC requires all wires passing through metal framing
paths to be protected by an approved smooth plastic grommet or bushing.