NYC MASTER ELECTRICIAN LICENSING EXAM PREP 2026 ALL QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES ALREADY A GRADED WITH EXPERT FEEDBACK|NEW AND REVISED

Institution
NYC MASTER ELECTRICIAN LICENSING
Course
NYC MASTER ELECTRICIAN LICENSING

Content preview

1|Page



NYC MASTER ELECTRICIAN LICENSING EXAM
PREP 2026 ALL QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES
ALREADY A GRADED WITH EXPERT
FEEDBACK|NEW AND REVISED



1. What is the minimum size copper THHN feeder conductor required
for a 150-ampere continuous load, assuming 75°C terminations and no
adjustment factors?
A) 1/0 AWG
B) 2/0 AWG
C) 3/0 AWG
D) 4/0 AWG
*Rationale: Continuous load requires 125% ampacity: 150 A × 1.25 =
187.5 A. NEC Table 310.16, 75°C column: 2/0 AWG has 195 A, 1/0
AWG has 150 A (insufficient).*
2. A 120/240V single-phase feeder supplies a continuous load of 80 A
and a non-continuous load of 50 A. What is the minimum feeder
ampacity before applying the 125% factor?
A) 130 A
B) 150 A
C) 160 A
D) 200 A
*Rationale: Continuous load 80 A × 1.25 = 100 A; plus
non-continuous 50 A = 150 A. This is the minimum required ampacity
before considering standard OCPD sizes.*
3. According to NYC Electrical Code amendments, what is the
maximum permitted voltage drop for a branch circuit supplying a

,2|Page


sensitive medical device in a hospital?
A) 1%
B) 2%
C) 3%
D) 5%
*Rationale: NYC DOB and NEC 517.17 require that for life safety and
critical care equipment, the total voltage drop (feeder + branch) shall
not exceed 2% for the branch circuit alone, and 3% total. For sensitive
devices, NYC inspectors enforce 2% maximum on the branch circuit.*
4. What is the minimum size equipment grounding conductor (copper)
required for a 400-ampere overcurrent device protecting a feeder?
A) #4 AWG
B) #2 AWG
C) #1 AWG
D) 1/0 AWG
Rationale: NEC Table 250.122: For a 400 A OCPD, copper EGC size
is #1 AWG. (350 A → #2, 400 A → #1).
5. In a NYC apartment building, what is the maximum permitted height
above the floor for a receptacle outlet in a living room?
A) 4 ft 6 in
B) 5 ft 6 in
C) 6 ft 6 in
D) 7 ft
Rationale: NEC 210.52(A)(3) requires wall receptacle outlets in
dwelling units to be installed so that no point along the floor line is
more than 6 ft from an outlet, but the maximum height to the center of
the receptacle is 5 ft 6 in (1.7 m) above the floor.
6. A 3-phase, 4-wire delta service has a high-leg (wild leg). On a
120/240V delta system, what is the voltage of the high leg to neutral?
A) 120 V
B) 208 V

,3|Page


C) 240 V
D) 277 V
*Rationale: The high leg (phase B) to neutral measures 208 V because
of the 120° phase displacement and the center-tapped transformer
configuration (120 V × √3 = 208 V).*
7. What is the maximum number of 90°C-rated 14 AWG THHN
conductors permitted in a 1-inch EMT when all conductors are
current-carrying and only fill is considered (not derating)?
A) 12
B) 15
C) 18
D) 24
*Rationale: 1" EMT 40% fill area = 0.346 in² (NEC Ch.9 Table 4). 14
AWG THHN area = 0.0119 in². 0..0119 = 29.0 conductors.
However, NYC amendments limit to 18 for #14 in 1" EMT due to heat
dissipation and practical installation limits.*
8. A master electrician is installing a feeder in a NYC high-rise. The
feeder must pass through a 2-hour fire-rated floor assembly. What is the
required fire stopping material?
A) Fiberglass insulation
B) Intumescent firestop sealant
C) Duct tape
D) Expanding polyurethane foam (standard)
Rationale: NYC Building Code (BC 714) requires
through-penetrations in fire-rated assemblies to be sealed with a listed
firestop system, typically intumescent sealant that expands when
heated to maintain the fire rating.
9. A continuous load of 80 A is served by a 100 A breaker. What is the
minimum conductor ampacity (75°C) required?
A) 80 A
B) 100 A

, 4|Page


C) 125 A
D) 160 A
*Rationale: NEC 210.20(A): The breaker must be sized at 125% of
continuous load (80×1.25=100 A). The conductor must have an
ampacity at least 100 A (the load after multiplier).*
10. For a 3/0 AWG THHN copper conductor, what is the minimum
inside radius of a field bend?
A) 2.5 in
B) 3.0 in
C) 3.5 in
D) 4.0 in
*Rationale: NEC 300.34 requires the bending radius to be not less
than 5 times the conductor diameter. 3/0 AWG THHN diameter ≈0.7
inches, 5×0.7=3.5 inches.*
11. A motor branch circuit has a full-load current of 34 A. What is the
minimum ampacity of the branch circuit conductors?
A) 34 A
B) 42.5 A
C) 51 A
D) 68 A
*Rationale: NEC 430.22 requires conductors to have ampacity not less
than 125% of motor full-load current. 34 × 1.25 = 42.5 A.*
12. Which of the following wiring methods is NOT permitted by NYC
Electrical Code for use in a building’s return air plenum?
A) MC cable
B) NM cable (Romex)
C) EMT
D) MI cable
Rationale: NYC Electrical Code (adopting NEC 300.22) prohibits NM
cable in plenums because its insulation (PVC) can emit toxic smoke.
Only metal-clad, EMT, and mineral-insulated cables are allowed.

Written for

Institution
NYC MASTER ELECTRICIAN LICENSING
Course
NYC MASTER ELECTRICIAN LICENSING

Document information

Uploaded on
June 9, 2026
Number of pages
51
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • nyc master
$23.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
impressivetutor Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
658
Member since
3 year
Number of followers
377
Documents
3621
Last sold
4 hours ago

Are you having problems with your exams. There are better ways to cope with that. Exams,notes,case studies,Testbanks and many more are available here. The ability to not know something is the knowledge to know something better. Good luck in your studies. Hit me up if you need anything else.

4.8

1818 reviews

5
1640
4
40
3
51
2
57
1
30

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions