MAINE STATE JOURNEYMAN EXAM UP TO 15GPH TEST STUDY GUIDE 2025/2026 ACCURATE QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES || 100% GUARANTEED PASS NEWEST VERSION A return line from a burner or a pump back to a supply tank shall have no valves or obstructions except for what? - ANSWER️A hard seat or ball valve with the handle removed An auxiliary tank shall be provided with an overflow pipe that drains where? - ANSWER️To the top of the supply tank Vent pipes from more than one tank shall be permitted to be manifolded and connected into one outlet pipe. True or False? - ANSWER️True What size shall the outlet pipe be of a joint vent manifold - ANSWER️At least one pipe size bigger than the largest individual vent pipe In no case shall the point of connection between two or more vent pipes be lower than the top of the fill pipe opening. True or False? - ANSWER️True Pressure testing fuel supply lines should last for no less than how many minutes? And what gauge pressure should be used? - ANSWER️At least 10 minutes No less than 5 but no more than 10 How long shall vacuum testing for leaks be held for how long? With how deep of a vacuum? - ANSWER️30 minutes 20 in The capacity of a single above ground tank or the aggregate capacity of two or more above ground tanks shall not exceed how many gallons? - ANSWER️20,000 Installation of oil-burning boilers with inputs above 12,500,000 BTU's shall meet what NFPA - ANSWER️NFPA 85 Oil burners other than oil stoves with integral tanks shall be provided with what? - ANSWER️A way to manually stop oil flow A down flow furnace shall be automatically operated and equipped with an approved temp control that will limit outlet air to what temp? - ANSWER️200 A duct furnace shall have what clearance to walls, ceilings, and floors of combustible materials? - ANSWER️6 inches A duct furnace flue pipe shall be installed to provide a clearance to combustibles of how many inches? - ANSWER️18 inches A floor furnace shall be placed not closer than how many inches to the nearest wall? And shall be placed so that a door, drapery, or similar object cannot be nearer than how many inches? - ANSWER️6 inches 12 inches Wall-registered models shall not be placed closer than how many inches to a corner? - ANSWER️6 inches How far from combustibles shall a floor furnace chimney connector be? - ANSWER️9 inches Rooms containing medium heat appliances shall be provided with what? - ANSWER️Ventilation High heat appliances shall be installed with clearances to combustibles of not less than how many feet at the side and rear? Above? And front? - ANSWER️10 feet 15 feet 30 feet A miscellaneous air heater shall be of a type designed to discharge air at a temp not to exceed what? - ANSWER️250 For rooftop units, how far back from the edge of the roof should the appliance be? - ANSWER️6 feet What voltage and type of receptacle outlet should be provided adjacent to the equipment? - ANSWER️120 volt AC grounding Flash point of No.1 and No. 2 oil is what? - ANSWER️100 What is the ignition point of No.2 heating oil is what? - ANSWER️500 What is the pour point of No.2 heating oil? - ANSWER️17 What is the minimum oil pump pressure - ANSWER️100 PSI What does NFPA limit shaft seal pressure to? - ANSWER️3 PSI What temperature should fusible links melt at? - ANSWER️165 What is the overfire draft reading? - ANSWER️-.02 (or manufacturer's specs) What is a breach draft? - ANSWER️-0.3 to -0.7

Content preview

MAINE STATE JOURNEYMAN EXAM UP TO
15GPH TEST STUDY GUIDE 2025/2026
ACCURATE QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES ||
100% GUARANTEED PASS NEWEST
VERSION



A return line from a burner or a pump back to a supply tank shall have no valves
or obstructions except for what? - ANSWER A hard seat or ball valve with the
handle removed


An auxiliary tank shall be provided with an overflow pipe that drains where? -
ANSWER To the top of the supply tank


Vent pipes from more than one tank shall be permitted to be manifolded and
connected into one outlet pipe. True or False? - ANSWER True



What size shall the outlet pipe be of a joint vent manifold - ANSWER At least
one pipe size bigger than the largest individual vent pipe

, In no case shall the point of connection between two or more vent pipes be lower
than the top of the fill pipe opening. True or False? - ANSWER True


Pressure testing fuel supply lines should last for no less than how many minutes?
And what gauge pressure should be used? - ANSWER At least 10 minutes
No less than 5 but no more than 10


How long shall vacuum testing for leaks be held for how long? With how deep of
a vacuum? - ANSWER 30 minutes
20 in


The capacity of a single above ground tank or the aggregate capacity of two or
more above ground tanks shall not exceed how many gallons? -
ANSWER 20,000


Installation of oil-burning boilers with inputs above 12,500,000 BTU's shall meet
what NFPA - ANSWER NFPA 85


Oil burners other than oil stoves with integral tanks shall be provided with what? -
ANSWER A way to manually stop oil flow


A down flow furnace shall be automatically operated and equipped with an
approved temp control that will limit outlet air to what temp? - ANSWER 200

,A duct furnace shall have what clearance to walls, ceilings, and floors of
combustible materials? - ANSWER 6 inches


A duct furnace flue pipe shall be installed to provide a clearance to combustibles
of how many inches? - ANSWER 18 inches


A floor furnace shall be placed not closer than how many inches to the nearest
wall? And shall be placed so that a door, drapery, or similar object cannot be nearer
than how many inches? - ANSWER 6 inches
12 inches


Wall-registered models shall not be placed closer than how many inches to a
corner? - ANSWER 6 inches


How far from combustibles shall a floor furnace chimney connector be? -
ANSWER 9 inches


Rooms containing medium heat appliances shall be provided with what? -
ANSWER Ventilation


High heat appliances shall be installed with clearances to combustibles of not less
than how many feet at the side and rear? Above? And front? - ANSWER 10 feet
15 feet
30 feet

, A miscellaneous air heater shall be of a type designed to discharge air at a temp
not to exceed what? - ANSWER 250


For rooftop units, how far back from the edge of the roof should the appliance be?
- ANSWER 6 feet


What voltage and type of receptacle outlet should be provided adjacent to the
equipment? - ANSWER 120 volt AC grounding



Flash point of No.1 and No. 2 oil is what? - ANSWER 100



What is the ignition point of No.2 heating oil is what? - ANSWER 500



What is the pour point of No.2 heating oil? - ANSWER 17


What is the minimum oil pump pressure - ANSWER 100 PSI



What does NFPA limit shaft seal pressure to? - ANSWER 3 PSI



What temperature should fusible links melt at? - ANSWER 165


What is the overfire draft reading? - ANSWER -.02 (or manufacturer's specs)



What is a breach draft? - ANSWER -0.3 to -0.7

Document information

Uploaded on
June 9, 2026
Number of pages
114
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
4
Followers
0
Items
263
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions